-- -- sNMP.MIB -- MIB generated by CAREL -- CAREL-sNMP-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF enterprises, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, IpAddress, Counter32, Unsigned32, TimeTicks, Opaque, Counter32, Gauge32 FROM SNMPv2-SMI DisplayString, TruthValue FROM SNMPv2-TC; sNMP MODULE-IDENTITY LAST-UPDATED "202202130710Z" -- February 13, 2022 at 07:10 GMT ORGANIZATION "CAREL Industries S.r.l." CONTACT-INFO " Carel Industries S.r.l. Via dell'Industria, 11 35020 Brugine (PD) Italy Tel: +39 049 9716611 E-mail: carel@carel.com " DESCRIPTION "This is the MIB module for the sNMP device." REVISION "202202130710Z" DESCRIPTION "" ::= { enterprises 9839 } -- ===================== -- -- Textual Conventions -- -- ===================== -- -- Define the Float Textual Convention -- This definition was written by David Perkins. -- Float ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A single precision floating-point number. The semantics and encoding are identical for type 'single' defined in IEEE Standard for Binary Floating-Point, ANSI/IEEE Std 754-1985. The value is restricted to the BER serialization of the following ASN.1 type: FLOATTYPE ::= [120] IMPLICIT FloatType (note: the value 120 is the sum of '30'h and '48'h) The BER serialization of the length for values of this type must use the definite length, short encoding form. For example, the BER serialization of value 123 of type FLOATTYPE is '9f780442f60000'h. (The tag is '9f78'h; the length is '04'h; and the value is '42f60000'h.) The BER serialization of value '9f780442f60000'h of data type Opaque is '44079f780442f60000'h. (The tag is '44'h; the length is '07'h; and the value is '9f780442f60000'h.)" SYNTAX Opaque (SIZE (7)) -- -- Node definitions -- -- 1.3.6.1.4.1.9839.1.2 snmpVariables OBJECT IDENTIFIER ::= { sNMP 1 2 } -- 1.3.6.1.4.1.9839.1.2.1.0 inputsMng-CompHiP-MaxVal OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {45} ::= { snmpVariables 1 } -- 1.3.6.1.4.1.9839.1.2.2.0 inputsMng-CompHiP-MinVal OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {0} ::= { snmpVariables 2 } -- 1.3.6.1.4.1.9839.1.2.3.0 inputsMng-AmbHum-MaxVal OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {150} ::= { snmpVariables 3 } -- 1.3.6.1.4.1.9839.1.2.4.0 inputsMng-AmbHum-MinVal OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {20} ::= { snmpVariables 4 } -- 1.3.6.1.4.1.9839.1.2.5.0 onOffUnitMng-CfgSupplyFanManPwr OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Manual-mode-supply-fan-speed-setting-Note-manual-mode-must-be-engaged-for-this-setting-to-take-effect-" DEFVAL {100} ::= { snmpVariables 5 } -- 1.3.6.1.4.1.9839.1.2.6.0 onOffUnitMng-CfgCondFanManPwr OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Manual-mode-condenser-fan-speed-setting-Note-manual-mode-must-be-engaged-for-this-setting-to-take-effect-" DEFVAL {100} ::= { snmpVariables 6 } -- 1.3.6.1.4.1.9839.1.2.7.0 onOffUnitMng-CfgCompManPwr OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Manual-mode-compressor-speed-setting-Note-manual-mode-must-be-engaged-for-this-setting-to-take-effect-" DEFVAL {80} ::= { snmpVariables 7 } -- 1.3.6.1.4.1.9839.1.2.8.0 regulationMng-RoomTempSetP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Indoor-temperature-setpoint-for-HVAC-when-it-loses-communication-with-controller-Default-26-1-C-79-F" DEFVAL {26} ::= { snmpVariables 8 } -- 1.3.6.1.4.1.9839.1.2.9.0 regulationMng-RoomTempSetP-Comfort OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Comfort-mode-temp-setpoint-Default-22-2-C-72-F" DEFVAL {22} ::= { snmpVariables 9 } -- 1.3.6.1.4.1.9839.1.2.10.0 roomTempSetP-ZoneList-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Zone-1-Temperature-Setpoint-This-is-the-main-temperature-setpoint-for-all-HVAC-units-unless-another-control-zone-is-set-up-Default-26-1-C-79-F" DEFVAL {26} ::= { snmpVariables 10 } -- 1.3.6.1.4.1.9839.1.2.11.0 roomTempSetP-ZoneList-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Zone-2-Temperature-Setpoint-Applicable-when-multiple-Control-Zones-has-been-set-up-Default-26-1-C-79-F" DEFVAL {26} ::= { snmpVariables 11 } -- 1.3.6.1.4.1.9839.1.2.12.0 roomTempSetP-ZoneList-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Zone-3-Temperature-Setpoint-Applicable-when-multiple-Control-Zones-has-been-set-up-Default-26-1-C-79-F" DEFVAL {26} ::= { snmpVariables 12 } -- 1.3.6.1.4.1.9839.1.2.13.0 roomTempSetP-ZoneList-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Zone-4-Temperature-Setpoint-Applicable-when-multiple-Control-Zones-has-been-set-up-Default-26-1-C-79-F" DEFVAL {26} ::= { snmpVariables 13 } -- 1.3.6.1.4.1.9839.1.2.14.0 roomTempDB OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Indoor-temperature-deadband-Cooling-demand-will-not-change-when-zone-temperature-is-within-setpoint-half-deadband-If-setpoint-is-80F-and-deadband-is-2F-cooling-demand-will-not-change-when-indoor-temperature-is-within-79-81F-Default-1-C-1-8-F" DEFVAL {1} ::= { snmpVariables 14 } -- 1.3.6.1.4.1.9839.1.2.15.0 compKp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {30} ::= { snmpVariables 15 } -- 1.3.6.1.4.1.9839.1.2.16.0 cool-Dead-Set OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Cooling-deadband-Temperature-above-main-setpoint-at-which-compressor-turns-on-For-example-if-setpoint-is-80F-and-cooling-deadband-is-2F-compressor-will-turn-on-at-82F-Default-1-11-C-2-F" DEFVAL {1} ::= { snmpVariables 16 } -- 1.3.6.1.4.1.9839.1.2.17.0 cool-Diff-Set OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Cooling-Differential-temperature-below-compressor-turn-on-point-that-compressor-turns-off-If-compressor-turns-on-at-82F-and-differential-is-6F-compressor-will-turn-off-at-76F-Default-3-33-C-6-F" DEFVAL {3} ::= { snmpVariables 17 } -- 1.3.6.1.4.1.9839.1.2.18.0 regulationMng-CompDehumSpeed OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Compressor-speed-during-dehumidification-Default-100-" DEFVAL {80} ::= { snmpVariables 18 } -- 1.3.6.1.4.1.9839.1.2.19.0 heat-Dead OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Heater-Deadband-temperature-below-main-setpoint-at-which-heater-turns-on-For-example-if-setpoint-is-80F-and-heater-deadband-is-20F-heater-will-turn-on-at-60F-Default-16-1-C-29-F" DEFVAL {16} ::= { snmpVariables 19 } -- 1.3.6.1.4.1.9839.1.2.20.0 heat-Diff OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Heater-Differential-temperature-above-heater-turn-point-that-heater-turns-off-If-heater-turns-on-at-60F-and-differential-is-3F-heater-will-turn-off-at-63F-Default-1-66-C-3-F" DEFVAL {2} ::= { snmpVariables 20 } -- 1.3.6.1.4.1.9839.1.2.21.0 regulationMng-SupplyFanKp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {4} ::= { snmpVariables 21 } -- 1.3.6.1.4.1.9839.1.2.22.0 supplyFanMaxSpeed-NoAC OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum-supply-fan-speed-when-the-unit-is-running-at-backup-power-Default-80-" DEFVAL {80} ::= { snmpVariables 22 } -- 1.3.6.1.4.1.9839.1.2.23.0 regulationMng-SupplyFanMaxSpeed-FC OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum-fan-speed-during-free-cooling-Default-100-" DEFVAL {100} ::= { snmpVariables 23 } -- 1.3.6.1.4.1.9839.1.2.24.0 supplyFanDehumSpeed OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Supply-fan-speed-during-dehumidification-Default-75-" DEFVAL {75} ::= { snmpVariables 24 } -- 1.3.6.1.4.1.9839.1.2.25.0 supplyFanTestSpeed-Comp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Supply-fan-speed-when-system-is-in-fixed-speed-mode-Default-80-" DEFVAL {80} ::= { snmpVariables 25 } -- 1.3.6.1.4.1.9839.1.2.26.0 regulationMng-SupplyFanMinSpeed OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum-allowed-fan-speed-Change-this-value-allows-enable-disable-constant-air-circulation-Default-30-" DEFVAL {30} ::= { snmpVariables 26 } -- 1.3.6.1.4.1.9839.1.2.27.0 humSetP-NoDehum OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum-humidity-for-free-cooling-Free-cooling-will-stop-when-indoor-humidity-reaches-this-maximum-to-prevent-bringing-more-outdoor-air-in-Should-more-cooling-needed-compressor-will-engage-which-reduces-humidity-levels-This-is-bypassed-during-emergency-ventilation-Default-85-" DEFVAL {85} ::= { snmpVariables 27 } -- 1.3.6.1.4.1.9839.1.2.28.0 humSetP-Dehum OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Dehumidification-target-setpoint-If-dehumidification-is-enabled-this-is-the-humidity-level-that-the-system-will-attempt-to-reach-Default-55-" DEFVAL {55} ::= { snmpVariables 28 } -- 1.3.6.1.4.1.9839.1.2.29.0 humDiff-Dehum OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Dehumidification-differential-Humidity-level-above-dehumidification-target-setpoint-at-which-dehumidification-starts-If-target-is-55-and-differential-is-15-dehumidification-will-start-when-humidity-reaches-70-Default-15-" DEFVAL {15} ::= { snmpVariables 29 } -- 1.3.6.1.4.1.9839.1.2.30.0 humDiff-LimFC OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Humidity-differential-for-free-cooling-Free-cooling-will-be-re-enabled-when-humidity-reaches-below-maximum-minus-differential-If-maximum-humidity-is-80-and-differential-is-10-free-cooling-will-re-enable-at-70-Default-5-" DEFVAL {5} ::= { snmpVariables 30 } -- 1.3.6.1.4.1.9839.1.2.31.0 dehumStartDiff-RoomTemp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Heater-differential-for-dehumidification-Dehumidification-will-engage-heater-when-the-room-is-too-cold-for-normal-compressor-based-dehumidification-This-is-the-temperature-differential-between-heater-start-and-heater-stop-during-dehumidification-If-heater-turns-on-for-dehumidification-at-67F-and-the-differential-is-6F-heater-will-turn-off-at-73-during-dehumidification-Default-5-" DEFVAL {3} ::= { snmpVariables 31 } -- 1.3.6.1.4.1.9839.1.2.32.0 dehumStop-RoomTemp-Diff OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Room-temperature-differential-for-dehumidification-with-heater-Dehumidification-will-engage-heater-when-the-room-is-too-cold-for-normal-compressor-based-dehumidification-This-is-the-temperature-differential-between-main-setpoint-and-room-temperature-for-heater-based-dehumidification-If-room-setpoint-is-80F-and-room-temperature-differential-is-12F-heater-based-dehumidification-will-trigger-room-temperature-falls-to-68F-Default-6-11-C-11-F" DEFVAL {6} ::= { snmpVariables 32 } -- 1.3.6.1.4.1.9839.1.2.33.0 fC-SetP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Free-cooling-setpoint-Minimum-temperature-differential-for-free-cooling-Free-cooling-will-be-enabled-if-the-indoor-temperature-minus-outdoor-temperature-is-larger-than-this-value-Default-2-C-3-6-F" DEFVAL {2} ::= { snmpVariables 33 } -- 1.3.6.1.4.1.9839.1.2.34.0 emergVentilationSetP-RoomTemp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Emergency-ventilation-setpoint-Temperature-above-main-setpoint-at-which-emergency-ventilation-will-activate-If-main-setpoint-is-80F-and-emergency-setpoint-is-15F-emergency-ventilation-will-start-at-95F-Emergency-ventilation-bypasses-humidity-dust-requirement-and-reduce-minimum-temperature-differential-to-0-1F-Compressors-will-still-operate-during-emergency-ventilation-if-they-are-not-locked-out-Default-7-8-C-14-F" DEFVAL {7} ::= { snmpVariables 34 } -- 1.3.6.1.4.1.9839.1.2.35.0 emergVentilationDiff-RoomTemp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Emergency-ventilation-differential-Temperature-below-emergency-ventilation-starting-point-at-which-emergency-ventilation-will-deactivate-If-emergency-ventilation-starts-at-94F-and-differential-is-10F-emergency-ventilation-will-start-when-indoor-temperature-reaches-84F-Default-5-C-9-F" DEFVAL {5} ::= { snmpVariables 35 } -- 1.3.6.1.4.1.9839.1.2.36.0 freeCooling-Dehumid-SupplyTempSetP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum-supply-air-temperature-for-free-cooling-When-supply-air-temperature-approaches-this-temperature-damper-will-modulate-to-keep-the-supply-temperature-above-this-setpoint-Default-10-C-50-F" DEFVAL {11} ::= { snmpVariables 36 } -- 1.3.6.1.4.1.9839.1.2.37.0 freeCooling-Dehumid-SupplyTempDB OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum-supply-air-temperature-deadband-Damper-will-modulate-when-supply-air-temperature-is-within-minimum-setpoint-deadband-Default-2-C-3-6-F" DEFVAL {1} ::= { snmpVariables 37 } -- 1.3.6.1.4.1.9839.1.2.38.0 freeCooling-Dehumid-DamperKp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {50} ::= { snmpVariables 38 } -- 1.3.6.1.4.1.9839.1.2.39.0 freeCooling-Dehumid-LimHiSupplyTemp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {2} ::= { snmpVariables 39 } -- 1.3.6.1.4.1.9839.1.2.40.0 freeCooling-Dehumid-LimLowSupplyTemp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {2} ::= { snmpVariables 40 } -- 1.3.6.1.4.1.9839.1.2.41.0 fC-Hyst OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Free-cooling-hysteresis-When-indoor-temperature-minus-outdoor-temperature-difference-is-smaller-than-this-value-free-cooling-will-stop-Default-2-C-3-6-F" DEFVAL {2} ::= { snmpVariables 41 } -- 1.3.6.1.4.1.9839.1.2.42.0 oilRecov-MinReqThrsh OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {55} ::= { snmpVariables 42 } -- 1.3.6.1.4.1.9839.1.2.43.0 oilRecov-CompMinSpeed OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {30} ::= { snmpVariables 43 } -- 1.3.6.1.4.1.9839.1.2.44.0 oilRecov-FrcCompSpeed OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {54} ::= { snmpVariables 44 } -- 1.3.6.1.4.1.9839.1.2.45.0 compNormSpeedPerc OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Compressor-speed-when-unit-is-in-fixed-speed-mode-Default-42-rps" DEFVAL {42} ::= { snmpVariables 45 } -- 1.3.6.1.4.1.9839.1.2.46.0 compMinSpeed OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum-compressor-speed-Default-27-rps" DEFVAL {27} ::= { snmpVariables 46 } -- 1.3.6.1.4.1.9839.1.2.47.0 condP-SetP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {27} ::= { snmpVariables 47 } -- 1.3.6.1.4.1.9839.1.2.48.0 condensingFan-CutOffDiff OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {1} ::= { snmpVariables 48 } -- 1.3.6.1.4.1.9839.1.2.49.0 condensingFan-CondKp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {30} ::= { snmpVariables 49 } -- 1.3.6.1.4.1.9839.1.2.50.0 condensingFan-MaxSpeed OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum-allowed-condenser-fan-speed-Default-100-" DEFVAL {100} ::= { snmpVariables 50 } -- 1.3.6.1.4.1.9839.1.2.51.0 condensingFan-MinSpeed OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum-allowed-condenser-fan-speed-Default-30-" DEFVAL {30} ::= { snmpVariables 51 } -- 1.3.6.1.4.1.9839.1.2.52.0 condensingFan-WipeSnowSetP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Snow-wiping-function-start-setpoint-When-outdoor-temperature-is-below-this-setpoint-and-Snow-wiping-is-enabled-condenser-fan-will-operate-periodically-to-prevent-snow-build-up-on-condenser-fan-Default-2-C-28-4-F" DEFVAL {-2} ::= { snmpVariables 52 } -- 1.3.6.1.4.1.9839.1.2.53.0 condensingFan-WipeSnowDiff OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Snow-wiping-function-start-deadband-When-outdoor-temperature-rise-above-setpoint-deadband-snow-wiping-will-stop-Default-2-5-C-4-5-F" DEFVAL {2} ::= { snmpVariables 53 } -- 1.3.6.1.4.1.9839.1.2.54.0 compTi OBJECT-TYPE SYNTAX Integer32 (0..9999) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {100} ::= { snmpVariables 54 } -- 1.3.6.1.4.1.9839.1.2.55.0 compTd OBJECT-TYPE SYNTAX Integer32 (0..9999) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {0} ::= { snmpVariables 55 } -- 1.3.6.1.4.1.9839.1.2.56.0 regulationMng-SupplyFanTi OBJECT-TYPE SYNTAX Integer32 (0..9999) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {30} ::= { snmpVariables 56 } -- 1.3.6.1.4.1.9839.1.2.57.0 regulationMng-SupplyFanTd OBJECT-TYPE SYNTAX Integer32 (0..9999) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 57 } -- 1.3.6.1.4.1.9839.1.2.58.0 freeCooling-Dehumid-DT-DehumHeat OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 58 } -- 1.3.6.1.4.1.9839.1.2.59.0 fC-Mode OBJECT-TYPE SYNTAX Integer32 (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Partial-free-cooling-mode-allows-free-cooling-and-compressor-to-run-at-the-same-time-0-Disable-Partial-freecooling-1-Enable-Partial-freecooling" ::= { snmpVariables 59 } -- 1.3.6.1.4.1.9839.1.2.60.0 fC-DT-RoomTemp OBJECT-TYPE SYNTAX Integer32 (0..600) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {10} ::= { snmpVariables 60 } -- 1.3.6.1.4.1.9839.1.2.61.0 freeCooling-Dehumid-DamperTi OBJECT-TYPE SYNTAX Integer32 (0..9999) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 61 } -- 1.3.6.1.4.1.9839.1.2.62.0 freeCooling-Dehumid-DamperTd OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 62 } -- 1.3.6.1.4.1.9839.1.2.63.0 oilRecov-WaitT OBJECT-TYPE SYNTAX Integer32 (0..300) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {60} ::= { snmpVariables 63 } -- 1.3.6.1.4.1.9839.1.2.64.0 oilRecov-FrcSpeedT OBJECT-TYPE SYNTAX Integer32 (1..300) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {3} ::= { snmpVariables 64 } -- 1.3.6.1.4.1.9839.1.2.65.0 condensingFan-DT-CondOff OBJECT-TYPE SYNTAX Integer32 (0..9999) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {20} ::= { snmpVariables 65 } -- 1.3.6.1.4.1.9839.1.2.66.0 condensingFan-CondTi OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {120} ::= { snmpVariables 66 } -- 1.3.6.1.4.1.9839.1.2.67.0 condensingFan-CondTd OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 67 } -- 1.3.6.1.4.1.9839.1.2.68.0 condensingFan-WipeSnow-CondFanOnT OBJECT-TYPE SYNTAX Integer32 (0..30) MAX-ACCESS read-write STATUS current DESCRIPTION "Condensing-fan-on-time-during-snow-wiping-If-on-time-is-set-to-1-min-and-off-time-is-set-to-20min-condenser-fan-will-operate-1min-after-every-20min-" DEFVAL {3} ::= { snmpVariables 68 } -- 1.3.6.1.4.1.9839.1.2.69.0 condensingFan-WipeSnow-CondFanOffT OBJECT-TYPE SYNTAX Integer32 (0..240) MAX-ACCESS read-write STATUS current DESCRIPTION "Condensing-fan-off-time-during-snow-wiping-If-on-time-is-set-to-1-min-and-off-time-is-set-to-20min-condenser-fan-will-operate-1min-after-every-20min-Default-20min" DEFVAL {30} ::= { snmpVariables 69 } -- 1.3.6.1.4.1.9839.1.2.70.0 onOffUnitMng-DT-CfgDamper OBJECT-TYPE SYNTAX Integer32 (1..600) MAX-ACCESS read-write STATUS current DESCRIPTION "Damper-open-close-cycle-time-during-test-mode-If-test-mode-is-enabled-for-damper-damper-will-oscillate-once-per-time-cycle-Default-1min" DEFVAL {1} ::= { snmpVariables 70 } -- 1.3.6.1.4.1.9839.1.2.71.0 onOffUnitMng-AutoTestStep OBJECT-TYPE SYNTAX Integer32 (0..5) MAX-ACCESS read-write STATUS current DESCRIPTION "Test-Mode-0-Off-test-mode-not-engaged-1-Supplyfan-2-Heater-3-Condenser-fan-4-Compressor-5-Fresh-Air-Damper" DEFVAL {0} ::= { snmpVariables 71 } -- 1.3.6.1.4.1.9839.1.2.72.0 iNV-Mng-EU-INV-Comm-DelayTime OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {20} ::= { snmpVariables 72 } -- 1.3.6.1.4.1.9839.1.2.73.0 eVD-Emb-1-Params-EVDEMB-1-EVD-MainRegulation-SH-Set-Val OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Superheat-setpoint-for-EEV-Default-10C-18F" DEFVAL {10} ::= { snmpVariables 73 } -- 1.3.6.1.4.1.9839.1.2.74.0 eVD-Emb-1-Params-EVDEMB-1-EVD-Regulation-StartEEV-OpRatio-Val OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {30} ::= { snmpVariables 74 } -- 1.3.6.1.4.1.9839.1.2.75.0 eVD-Emb-1-Params-EVDEMB-1-EVD-Regulation-SH-WaitDT-Val OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {10} ::= { snmpVariables 75 } -- 1.3.6.1.4.1.9839.1.2.76.0 eVD-Emb-1-Params-EVDEMB-1-EVD-MainRegulation-MOP-Thrsh-Val OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {15} ::= { snmpVariables 76 } -- 1.3.6.1.4.1.9839.1.2.77.0 eVD-Emb-1-Params-EVDEMB-1-EVD-MainRegulation-MOP-Ti-Val OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 77 } -- 1.3.6.1.4.1.9839.1.2.78.0 eVD-Emb-1-Params-EVDEMB-1-EVD-Regulation-MOP-AlrmDT-Val OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 78 } -- 1.3.6.1.4.1.9839.1.2.79.0 iNV-Max-Speed-Limt OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {64} ::= { snmpVariables 79 } -- 1.3.6.1.4.1.9839.1.2.80.0 iNV-Mng-EU-Comp-Compress-Rate OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {1} ::= { snmpVariables 80 } -- 1.3.6.1.4.1.9839.1.2.81.0 iNV-Mng-EU-Comp-Increa-Step OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {30} ::= { snmpVariables 81 } -- 1.3.6.1.4.1.9839.1.2.82.0 iNV-Mng-EU-Comp-Decrea-Step OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {30} ::= { snmpVariables 82 } -- 1.3.6.1.4.1.9839.1.2.83.0 iNV-Mng-EU-Comp-DecreaSer-Step OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {90} ::= { snmpVariables 83 } -- 1.3.6.1.4.1.9839.1.2.84.0 iNV-Mng-EU-Comp-Press-Control-Cycle OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {195} ::= { snmpVariables 84 } -- 1.3.6.1.4.1.9839.1.2.85.0 iNV-Mng-EU-Comp-Disc-Limit-Set OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {90} ::= { snmpVariables 85 } -- 1.3.6.1.4.1.9839.1.2.86.0 iNV-Mng-EU-Comp-Disc-Protect-Set OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {95} ::= { snmpVariables 86 } -- 1.3.6.1.4.1.9839.1.2.87.0 iNV-Mng-EU-Comp-Disc-Diff OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {5} ::= { snmpVariables 87 } -- 1.3.6.1.4.1.9839.1.2.88.0 iNV-Mng-EU-Comp-Disc-Alarm-Set OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {120} ::= { snmpVariables 88 } -- 1.3.6.1.4.1.9839.1.2.89.0 iNV-Mng-EU-Comp-Start-Speed OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {30} ::= { snmpVariables 89 } -- 1.3.6.1.4.1.9839.1.2.90.0 iNV-Mng-EU-Comp-Start-Keep-Speed OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {40} ::= { snmpVariables 90 } -- 1.3.6.1.4.1.9839.1.2.91.0 generalMng-WipeMem-1- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "Initialization-type-This-is-initiation-which-wipes-all-parameter-changes-and-restore-to-default-values-1-reset-to-factory-default-2-reset-to-end-user-specific-default-values-only-valid-when-user-has-requested-default-setpoints-other-than-factory-default-built-into-software-otherwise-software-will-reset-to-factory-default-" DEFVAL {1} ::= { snmpVariables 91 } -- 1.3.6.1.4.1.9839.1.2.92.0 iNV-Mng-EU-Comp-Start-Keep-Time OBJECT-TYPE SYNTAX Integer32 (0..600) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {195} ::= { snmpVariables 92 } -- 1.3.6.1.4.1.9839.1.2.93.0 comp-Min-RunT OBJECT-TYPE SYNTAX Integer32 (30..600) MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum-compressor-run-time-Default-180s" DEFVAL {180} ::= { snmpVariables 93 } -- 1.3.6.1.4.1.9839.1.2.94.0 comp-Min-StopT OBJECT-TYPE SYNTAX Integer32 (30..600) MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum-compressor-stop-time-Time-between-compressor-stop-and-the-next-time-it-starts-Default-180s" DEFVAL {180} ::= { snmpVariables 94 } -- 1.3.6.1.4.1.9839.1.2.95.0 comp-Between-Min OBJECT-TYPE SYNTAX Integer32 (30..600) MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum-time-between-each-compressor-start-Default-360s" DEFVAL {360} ::= { snmpVariables 95 } -- 1.3.6.1.4.1.9839.1.2.96.0 comfort-Keep OBJECT-TYPE SYNTAX Integer32 (5..300) MAX-ACCESS read-write STATUS current DESCRIPTION "Comfort-mode-run-time-Default-60min" DEFVAL {60} ::= { snmpVariables 96 } -- 1.3.6.1.4.1.9839.1.2.97.0 unit-Model OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {2} ::= { snmpVariables 97 } -- 1.3.6.1.4.1.9839.1.2.98.0 alarmMng-HiRoomTemp-SetP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "High-temperature-alarm-setpoint-Alarm-will-trigger-if-room-temperature-reaches-main-setpoint-alarm-setpoint-If-room-setpoint-is-80F-and-alarm-setpoint-is-10F-high-temp-alarm-will-trigger-at-90F-Default-8-9-C-16-F" DEFVAL {8} ::= { snmpVariables 98 } -- 1.3.6.1.4.1.9839.1.2.99.0 alarmMng-HiRoomTempDT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "High-temperature-alarm-delay-Delay-before-high-temp-alarm-trigger-Default-60s" DEFVAL {60} ::= { snmpVariables 99 } -- 1.3.6.1.4.1.9839.1.2.100.0 alarmMng-LowSupplyTemp-SetP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Low-supply-temperature-alarm-setpoint-Alarm-will-trigger-if-supply-temperature-reaches-minimum-supply-temperature-alarm-setpoint-If-minimum-supply-temperature-is-50F-and-alarm-setpoint-is-10F-low-supply-temp-alarm-will-trigger-at-40F-Default-6-C-10-8-F" DEFVAL {6} ::= { snmpVariables 100 } -- 1.3.6.1.4.1.9839.1.2.101.0 alarmMng-LowSupplyTempDT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Low-supply-temperature-alarm-delay-Delay-before-low-supply-temp-alarm-triggers-Default-36s" DEFVAL {20} ::= { snmpVariables 101 } -- 1.3.6.1.4.1.9839.1.2.102.0 alarmMng-Damper-CheckDT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Damper-alarm-check-time-Time-between-each-time-the-system-checks-damper-operation-Default-5min" DEFVAL {5} ::= { snmpVariables 102 } -- 1.3.6.1.4.1.9839.1.2.103.0 alarmMng-Damper-RetryDutyT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Damper-alarm-retry-time-Time-allowed-for-damper-alarm-to-try-again-should-the-first-one-fail-Default-60min" DEFVAL {60} ::= { snmpVariables 103 } -- 1.3.6.1.4.1.9839.1.2.104.0 alarmMng-Damper-RetryNo OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Damper-alarm-retry-number-Number-of-retries-before-a-damper-alarm-is-triggered-Default-3" DEFVAL {3} ::= { snmpVariables 104 } -- 1.3.6.1.4.1.9839.1.2.105.0 alarmMng-Damper-AlrmT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Damper-alarm-delay-Damper-alarm-will-trigger-if-the-alarm-condition-continues-for-this-amount-of-time-Default-12min" DEFVAL {12} ::= { snmpVariables 105 } -- 1.3.6.1.4.1.9839.1.2.106.0 alarmMng-Dust-RetryT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {1} ::= { snmpVariables 106 } -- 1.3.6.1.4.1.9839.1.2.107.0 alarmMng-Dust-AutoResT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Dust-alarm-reset-time-Dust-alarm-will-reset-if-no-trigger-events-occur-in-this-interval-Default-1hr" DEFVAL {1} ::= { snmpVariables 107 } -- 1.3.6.1.4.1.9839.1.2.108.0 alarmMng-Dust-CloseDamperDT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Dust-alarm-damper-closed-time-Fresh-air-damper-will-stay-closed-for-this-amount-of-time-before-opening-again-if-a-dust-alarm-is-detected-" DEFVAL {60} ::= { snmpVariables 108 } -- 1.3.6.1.4.1.9839.1.2.109.0 alarmMng-SupplyFanOvld-StartDT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Supply-fan-overload-alarm-start-delay-Alarm-will-only-trigger-after-supply-fan-has-started-to-run-for-at-least-this-amount-of-delay-Default-20s" DEFVAL {20} ::= { snmpVariables 109 } -- 1.3.6.1.4.1.9839.1.2.110.0 alarmMng-SupplyFanOvld-RunDT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Supply-fan-overload-alarm-running-delay-Alarm-will-only-trigger-if-the-supply-fan-has-been-in-continuous-alarm-for-this-amount-of-seconds-Default-10s" DEFVAL {10} ::= { snmpVariables 110 } -- 1.3.6.1.4.1.9839.1.2.111.0 alarmMng-MechanicalCoolDefect-StartDT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Mechanical-cooling-high-supply-temperature-alarm-start-delay-Alarm-will-only-trigger-after-compressor-has-started-to-run-for-at-least-this-amount-of-delay-Default-1min" DEFVAL {1} ::= { snmpVariables 111 } -- 1.3.6.1.4.1.9839.1.2.112.0 alarmMng-MechanicalCoolDefect-SetP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Mechanical-cooling-high-supply-temperature-alarm-differential-When-return-temperature-minus-supply-temperature-is-greater-than-this-differential-after-the-compressor-has-been-running-a-mechanical-cooling-alarm-will-be-triggered-If-the-return-temperature-is-90F-and-differential-is-5F-an-alarm-will-trigger-if-supply-temperature-is-greater-than-85F-Default-3-C-5-4-F" DEFVAL {3} ::= { snmpVariables 112 } -- 1.3.6.1.4.1.9839.1.2.113.0 alarmMng-MechanicalCooDefect-RunDT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Mechanical-cooling-high-supply-temperature-alarm-running-delay-Alarm-will-only-trigger-if-the-compressor-has-been-in-continuous-alarm-for-this-amount-of-seconds-Default-60s" DEFVAL {60} ::= { snmpVariables 113 } -- 1.3.6.1.4.1.9839.1.2.114.0 alarmMng-Damper-CompOffDT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Damper-alarm-delay-for-compressor-Damper-check-will-only-performed-after-compressor-stop-was-stopped-for-this-amount-of-time-Default-3min" DEFVAL {5} ::= { snmpVariables 114 } -- 1.3.6.1.4.1.9839.1.2.115.0 alarmMng-Damper-OffTempDiff OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Damper-alarm-closed-temperature-differential-Maximum-temperature-differential-between-room-and-supply-temperature-when-damper-is-closed-If-return-temperature-is-90F-and-closed-differential-is-10F-the-system-will-go-into-alarm-if-supply-temperature-is-below-80F-signaling-the-damper-has-not-properly-closed-Default-5-56C-10F" DEFVAL {9} ::= { snmpVariables 115 } -- 1.3.6.1.4.1.9839.1.2.116.0 alarmMng-Damper-OnTempDiff OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Damper-alarm-open-temperature-differential-Maximum-temperature-differential-between-outdoor-and-supply-temperature-when-damper-is-open-If-outdoor-temperature-is-60F-and-closed-differential-is-10F-the-system-will-go-into-alarm-if-supply-temperature-is-above-70F-signaling-the-damper-has-not-properly-opened-Default-5-56C-10F" DEFVAL {3} ::= { snmpVariables 116 } -- 1.3.6.1.4.1.9839.1.2.117.0 alarmMng-LowP-StartDT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Low-pressure-alarm-delay-for-compressor-Alarm-will-only-trigger-after-compressor-has-been-running-for-this-time-Default-30s" DEFVAL {90} ::= { snmpVariables 117 } -- 1.3.6.1.4.1.9839.1.2.118.0 alarmMng-LowP-SetP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Low-pressure-alarm-trigger-point-Default-4-1-Bar-60-psi" DEFVAL {4} ::= { snmpVariables 118 } -- 1.3.6.1.4.1.9839.1.2.119.0 alarmMng-LowP-RunDT OBJECT-TYPE SYNTAX Integer32 (15..900) MAX-ACCESS read-write STATUS current DESCRIPTION "Low-pressure-alarm-running-delay-Alarm-will-only-trigger-if-the-pressure-has-been-in-continuously-below-the-trigger-point-for-this-amount-of-time-Default-10s" DEFVAL {60} ::= { snmpVariables 119 } -- 1.3.6.1.4.1.9839.1.2.120.0 alarmMng-LowP-LimSetP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Low-pressure-limit-Pressure-value-where-the-compressor-will-immediately-stop-Default-3-3-Bar-48-psi" DEFVAL {3} ::= { snmpVariables 120 } -- 1.3.6.1.4.1.9839.1.2.121.0 alarmMng-LowP-LimHyst OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Low-pressure-limit-hysteresis-Pressure-level-above-limit-where-compressor-will-be-enabled-again-Default-2-0-Bar-29-psi" DEFVAL {2} ::= { snmpVariables 121 } -- 1.3.6.1.4.1.9839.1.2.122.0 alarmMng-CompHiP-SetP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "High-pressure-alarm-trigger-point-Default-41-0-Bar-595-psi" DEFVAL {41} ::= { snmpVariables 122 } -- 1.3.6.1.4.1.9839.1.2.123.0 inputsMng-SuctP-MaxVal OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {35} ::= { snmpVariables 123 } -- 1.3.6.1.4.1.9839.1.2.124.0 condensingFan-CondP-DB OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {0} ::= { snmpVariables 124 } -- 1.3.6.1.4.1.9839.1.2.125.0 exBoard-EU-DevBaud-Msk OBJECT-TYPE SYNTAX Integer32 (0..5) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {3} ::= { snmpVariables 125 } -- 1.3.6.1.4.1.9839.1.2.126.0 exBoard-EU-Valve-Max-Step OBJECT-TYPE SYNTAX Integer32 (0..5000) MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {250} ::= { snmpVariables 126 } -- 1.3.6.1.4.1.9839.1.2.127.0 valve-SH-Set OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {7} ::= { snmpVariables 127 } -- 1.3.6.1.4.1.9839.1.2.128.0 exBoard-EU-Valve-MOP-Set OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {13} ::= { snmpVariables 128 } -- 1.3.6.1.4.1.9839.1.2.129.0 iNV-Mng-EU-Comp-Control-Rate-EU OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {1} ::= { snmpVariables 129 } -- 1.3.6.1.4.1.9839.1.2.130.0 iNV-Mng-EU-Comp-Start-HL-Diff-EU OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {8} ::= { snmpVariables 130 } -- 1.3.6.1.4.1.9839.1.2.131.0 comp-DG-Stop-Time OBJECT-TYPE SYNTAX Integer32 (0..9999) MAX-ACCESS read-write STATUS current DESCRIPTION "Compressor-stop-time-after-generator-alarm-is-triggered-or-restored-This-is-to-eliminate-compressor-rotation-issue-during-brief-power-transitions-Default-180s" DEFVAL {180} ::= { snmpVariables 131 } -- 1.3.6.1.4.1.9839.1.2.132.0 master-Logic-Cool-Force-Diff-Set OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Cooling-differential-for-backup-units-Backup-units-will-start-to-cool-if-indoor-temperature-rises-above-setpoint-differential-Default-4-44-C-8-F" DEFVAL {4} ::= { snmpVariables 132 } -- 1.3.6.1.4.1.9839.1.2.133.0 inputsMng-U8-MinVal OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {0} ::= { snmpVariables 133 } -- 1.3.6.1.4.1.9839.1.2.134.0 inputsMng-U8-MaxVal OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {0} ::= { snmpVariables 134 } -- 1.3.6.1.4.1.9839.1.2.135.0 lowP-AmbDT OBJECT-TYPE SYNTAX Integer32 (0..300) MAX-ACCESS read-write STATUS current DESCRIPTION "Low-pressure-alarm-delay-time-in-case-of-low-outdoor-temperature-Default-60s" DEFVAL {120} ::= { snmpVariables 135 } -- 1.3.6.1.4.1.9839.1.2.136.0 ambHum-Backup OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 136 } -- 1.3.6.1.4.1.9839.1.2.137.0 supplyFanNorSpeed-Comp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Max-supply-fan-speed-when-the-compressor-is-on-and-in-variable-speed-mode-Default-93-" DEFVAL {93} ::= { snmpVariables 137 } -- 1.3.6.1.4.1.9839.1.2.138.0 alarmMng-Air-Press-Set OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Filter-alarm-setpoint-Air-pressure-level-where-filter-alarm-will-trigger-Default-0-25-kPa" DEFVAL {1} ::= { snmpVariables 138 } -- 1.3.6.1.4.1.9839.1.2.139.0 alarmMng-Air-Press-Diff OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Filter-alarm-differential-Air-pressure-level-below-setpoint-where-filter-alarm-will-clear-Default-0-05-kPa" DEFVAL {1} ::= { snmpVariables 139 } -- 1.3.6.1.4.1.9839.1.2.140.0 minDamperPos OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum-damper-position-Increase-from-0-to-enable-constant-outside-air-intake-Default-0-" DEFVAL {0} ::= { snmpVariables 140 } -- 1.3.6.1.4.1.9839.1.2.141.0 alarmMng-LoRoomTempDT OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Low-temperature-alarm-delay-Delay-before-low-temp-alarm-trigger-Default-60s" DEFVAL {60} ::= { snmpVariables 141 } -- 1.3.6.1.4.1.9839.1.2.142.0 alarmMng-LoRoomTemp-SetP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Low-temperature-alarm-setpoint-Alarm-will-trigger-if-room-temperature-reaches-main-setpoint-minus-alarm-setpoint-If-room-setpoint-is-80F-and-alarm-setpoint-is-30F-high-temp-alarm-will-trigger-at-50F-Default-18-9-C-34-F" DEFVAL {18} ::= { snmpVariables 142 } -- 1.3.6.1.4.1.9839.1.2.143.0 sC-Set OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {5} ::= { snmpVariables 143 } -- 1.3.6.1.4.1.9839.1.2.144.0 sC-Diff OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {3} ::= { snmpVariables 144 } -- 1.3.6.1.4.1.9839.1.2.145.0 sC-Set-Alarm OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {80} ::= { snmpVariables 145 } -- 1.3.6.1.4.1.9839.1.2.146.0 ambTemp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Outdoor-temperature-reading-as-read-from-controller-s-outdoor-temperature-sensor-" DEFVAL {18} ::= { snmpVariables 146 } -- 1.3.6.1.4.1.9839.1.2.147.0 roomTemp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Room-temperature-1-This-is-the-main-room-temperature-reading-unless-multiple-control-zone-has-been-set-up-" DEFVAL {23} ::= { snmpVariables 147 } -- 1.3.6.1.4.1.9839.1.2.148.0 roomTemp2 OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Room-temperature-2-Applicable-when-multiple-Control-Zones-has-been-set-up-" ::= { snmpVariables 148 } -- 1.3.6.1.4.1.9839.1.2.149.0 roomTemp3 OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Room-temperature-3-Applicable-when-multiple-Control-Zones-has-been-set-up-" ::= { snmpVariables 149 } -- 1.3.6.1.4.1.9839.1.2.150.0 roomTemp4 OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Room-temperature-4-Applicable-when-multiple-Control-Zones-has-been-set-up-" ::= { snmpVariables 150 } -- 1.3.6.1.4.1.9839.1.2.151.0 bLDC-Mng-Info-BLDC1-Press-DscgP-Bar OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 151 } -- 1.3.6.1.4.1.9839.1.2.152.0 bLDC-Mng-Info-BLDC1-Press-SuctP-Bar OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 152 } -- 1.3.6.1.4.1.9839.1.2.153.0 bLDC-Mng-Info-BLDC1-Info-EnvZone OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 153 } -- 1.3.6.1.4.1.9839.1.2.154.0 bLDC-Mng-Info-BLDC1-Time-CntDwnOutEnv OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 154 } -- 1.3.6.1.4.1.9839.1.2.155.0 bLDC-Mng-Info-BLDC1-Press-DeltaP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 155 } -- 1.3.6.1.4.1.9839.1.2.156.0 bLDC-Mng-Info-BLDC1-Press-RatioP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 156 } -- 1.3.6.1.4.1.9839.1.2.157.0 bLDC-Mng-Info-BLDC1-Time-CntDwnDeltaPAlrm OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 157 } -- 1.3.6.1.4.1.9839.1.2.158.0 eVD-Emb-1-Params-EVDEMB-1-EVD-Variables-SH-UnitCoolCap-Val OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 158 } -- 1.3.6.1.4.1.9839.1.2.159.0 eVD-Emb-1-Params-EVDEMB-1-EVD-Variables-DscgTemp-Val OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 159 } -- 1.3.6.1.4.1.9839.1.2.160.0 eVD-Emb-1-Params-EVDEMB-1-EVD-Variables-CondTemp-Val OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 160 } -- 1.3.6.1.4.1.9839.1.2.161.0 eVD-Emb-1-Params-EVDEMB-1-EVD-Variables-SH-SuctTemp-Val OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 161 } -- 1.3.6.1.4.1.9839.1.2.162.0 eVD-Emb-1-Params-EVDEMB-1-EVD-Variables-SH-EvapTemp-Val OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 162 } -- 1.3.6.1.4.1.9839.1.2.163.0 eVD-Emb-1-Params-EVDEMB-1-EVD-Variables-EEV-PosSteps-Val OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 163 } -- 1.3.6.1.4.1.9839.1.2.164.0 eVD-Emb-1-Params-EVDEMB-1-EVD-Variables-EEV-PosPercent-Val OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 164 } -- 1.3.6.1.4.1.9839.1.2.165.0 eVD-Emb-1-Params-EVDEMB-1-EVD-Variables-DscgSH-Val OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 165 } -- 1.3.6.1.4.1.9839.1.2.166.0 eVD-Emb-1-Params-EVDEMB-1-EVD-Variables-RegStatus-Val OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 166 } -- 1.3.6.1.4.1.9839.1.2.167.0 eVD-Emb-1-Params-EVDEMB-1-EVD-Variables-ProtStatus-Val OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 167 } -- 1.3.6.1.4.1.9839.1.2.168.0 supplyTemp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 168 } -- 1.3.6.1.4.1.9839.1.2.169.0 compHiP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 169 } -- 1.3.6.1.4.1.9839.1.2.170.0 dscgTemp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 170 } -- 1.3.6.1.4.1.9839.1.2.171.0 suctTemp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 171 } -- 1.3.6.1.4.1.9839.1.2.172.0 suctP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 172 } -- 1.3.6.1.4.1.9839.1.2.173.0 supplyFanPwrReq OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Supply-Fan-Speed-0-1-" ::= { snmpVariables 173 } -- 1.3.6.1.4.1.9839.1.2.174.0 damperPos OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Damper-Position-0-1-" ::= { snmpVariables 174 } -- 1.3.6.1.4.1.9839.1.2.175.0 condensingFan-CondFanPwrReq OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 175 } -- 1.3.6.1.4.1.9839.1.2.176.0 sTD-UOM-ZONE-UI OBJECT-TYPE SYNTAX Integer32 (0..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Unit-of-Measurement-Standard-0-No-Conversion-SI-1-SI-2-USA-3-UK-4-Canada" DEFVAL {2} ::= { snmpVariables 176 } -- 1.3.6.1.4.1.9839.1.2.177.0 compSpeed OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Compressor-Speed-0-1rps-" ::= { snmpVariables 177 } -- 1.3.6.1.4.1.9839.1.2.178.0 regulationMng-CompPID-PwrReq OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 178 } -- 1.3.6.1.4.1.9839.1.2.179.0 bLDC-Mng-Info-BLDC1-Info-CompRequest OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 179 } -- 1.3.6.1.4.1.9839.1.2.180.0 bLDC-Mng-Info-BLDC1-Info-ReqSpeedToPWRP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 180 } -- 1.3.6.1.4.1.9839.1.2.181.0 bLDC-Mng-Info-PWRP1-Info-RotorSpeed-rps OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 181 } -- 1.3.6.1.4.1.9839.1.2.182.0 iNV-Actual-Speed-Cap-Tr OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 182 } -- 1.3.6.1.4.1.9839.1.2.183.0 iNV-DC-Power-Tr OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 183 } -- 1.3.6.1.4.1.9839.1.2.184.0 iNV-Current-Tr OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 184 } -- 1.3.6.1.4.1.9839.1.2.185.0 iNV-OutTemp-Tr OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 185 } -- 1.3.6.1.4.1.9839.1.2.186.0 press-DeltaP OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 186 } -- 1.3.6.1.4.1.9839.1.2.187.0 press-Rato OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 187 } -- 1.3.6.1.4.1.9839.1.2.188.0 cond-Temp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Condensing-Temperature" ::= { snmpVariables 188 } -- 1.3.6.1.4.1.9839.1.2.189.0 evap-Temp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Evaporating-Temperature" ::= { snmpVariables 189 } -- 1.3.6.1.4.1.9839.1.2.190.0 exBoard-EU-Valve-Open-Pos OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 190 } -- 1.3.6.1.4.1.9839.1.2.191.0 exBoard-EU-Valve-Open-Step-Tr OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 191 } -- 1.3.6.1.4.1.9839.1.2.192.0 inputsMng-ExAlrmWord1 OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 192 } -- 1.3.6.1.4.1.9839.1.2.193.0 sH-Cond OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 193 } -- 1.3.6.1.4.1.9839.1.2.194.0 sH-Evap OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 194 } -- 1.3.6.1.4.1.9839.1.2.195.0 iNV-Temperature-Tr OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 195 } -- 1.3.6.1.4.1.9839.1.2.196.0 alarmMng-AlrmWord-SlaveTOMaster1 OBJECT-TYPE SYNTAX Integer32 (-2147483648..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 196 } -- 1.3.6.1.4.1.9839.1.2.197.0 alarmMng-AlrmWord-SlaveTOMaster2 OBJECT-TYPE SYNTAX Integer32 (-2147483648..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 197 } -- 1.3.6.1.4.1.9839.1.2.198.0 hoursCounterMng-UnitLifeT OBJECT-TYPE SYNTAX Integer32 (0..9999999) MAX-ACCESS read-only STATUS current DESCRIPTION "Unit-Running-Hours-Unit-refers-to-the-device-that-is-being-monitored-If-monitoring-the-controller-through-SNMP-this-is-the-running-hour-of-the-main-controller-" ::= { snmpVariables 198 } -- 1.3.6.1.4.1.9839.1.2.199.0 generalMng-LastOnYear OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Last-On-Year-Year-of-when-the-device-was-last-on-before-power-off-If-monitoring-the-controller-through-SNMP-this-refers-to-the-main-controller-17-2017" ::= { snmpVariables 199 } -- 1.3.6.1.4.1.9839.1.2.200.0 generalMng-LastOnMonth OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Last-On-Month-Month-of-when-the-device-was-last-on-before-power-off-If-monitoring-the-controller-through-SNMP-this-refers-to-the-main-controller-" ::= { snmpVariables 200 } -- 1.3.6.1.4.1.9839.1.2.201.0 generalMng-LastOnDay OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Last-On-Day-Day-of-when-the-device-was-last-on-before-power-off-If-monitoring-the-controller-through-SNMP-this-refers-to-the-main-controller-" ::= { snmpVariables 201 } -- 1.3.6.1.4.1.9839.1.2.202.0 generalMng-LastOnHour OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Last-On-Hour-Hour-of-when-the-device-was-last-on-before-power-off-If-monitoring-the-controller-through-SNMP-this-refers-to-the-main-controller-" ::= { snmpVariables 202 } -- 1.3.6.1.4.1.9839.1.2.203.0 generalMng-LastOnMinute OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Last-On-Minute-Minute-of-when-the-device-was-last-on-before-power-off-If-monitoring-the-controller-through-SNMP-this-refers-to-the-main-controller-" ::= { snmpVariables 203 } -- 1.3.6.1.4.1.9839.1.2.204.0 generalMng-LastOnSecond OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Last-On-Second-Second-of-when-the-device-was-last-on-before-power-off-If-monitoring-the-controller-through-SNMP-this-refers-to-the-main-controller-" ::= { snmpVariables 204 } -- 1.3.6.1.4.1.9839.1.2.205.0 generalMng-OffDays OBJECT-TYPE SYNTAX Integer32 (0..999) MAX-ACCESS read-only STATUS current DESCRIPTION "Off-Days-Duration-of-the-last-power-off-of-device-If-monitoring-the-controller-through-SNMP-this-refers-to-the-main-controller-" ::= { snmpVariables 205 } -- 1.3.6.1.4.1.9839.1.2.206.0 generalMng-OffHours OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Off-Hours-Duration-of-the-last-power-off-of-device-If-monitoring-the-controller-through-SNMP-this-refers-to-the-main-controller-" ::= { snmpVariables 206 } -- 1.3.6.1.4.1.9839.1.2.207.0 generalMng-OffMinutes OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Off-Minutes-Duration-of-the-last-power-off-of-device-If-monitoring-the-controller-through-SNMP-this-refers-to-the-main-controller-" ::= { snmpVariables 207 } -- 1.3.6.1.4.1.9839.1.2.208.0 compPwrReq-BLDC OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 208 } -- 1.3.6.1.4.1.9839.1.2.209.0 filter-Air-Press OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 209 } -- 1.3.6.1.4.1.9839.1.2.210.0 unitStatus OBJECT-TYPE SYNTAX Integer32 (0..9) MAX-ACCESS read-only STATUS current DESCRIPTION "Status-of-the-monitored-unit-If-monitoring-the-controller-through-SNMP-this-is-the-status-of-the-main-controller-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 210 } -- 1.3.6.1.4.1.9839.1.2.211.0 kWH-Value-1H OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-One-hour-average-KW-consumption" ::= { snmpVariables 211 } -- 1.3.6.1.4.1.9839.1.2.212.0 kWH-Value-30Day OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-30-Day-average-KW-consumption" ::= { snmpVariables 212 } -- 1.3.6.1.4.1.9839.1.2.213.0 temp-Power-S OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 213 } -- 1.3.6.1.4.1.9839.1.2.214.0 hoursCounterMng-SupplyFanRunTime OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 214 } -- 1.3.6.1.4.1.9839.1.2.215.0 hoursCounterMng-CompRunTime OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 215 } -- 1.3.6.1.4.1.9839.1.2.216.0 hoursCounterMng-HeaterRunTime OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 216 } -- 1.3.6.1.4.1.9839.1.2.217.0 hoursCounterMng-FCRunTime OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 217 } -- 1.3.6.1.4.1.9839.1.2.218.0 hoursCounterMng-SupplyFanStartTime OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 218 } -- 1.3.6.1.4.1.9839.1.2.219.0 hoursCounterMng-CompStartTime OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 219 } -- 1.3.6.1.4.1.9839.1.2.220.0 hoursCounterMng-HeaterStartTime OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 220 } -- 1.3.6.1.4.1.9839.1.2.221.0 hoursCounterMng-FCStartTime OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 221 } -- 1.3.6.1.4.1.9839.1.2.222.0 supplyFanFeedback-F OBJECT-TYPE SYNTAX Integer32 (0..7200) MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 222 } -- 1.3.6.1.4.1.9839.1.2.223.0 conden-Temp OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 223 } -- 1.3.6.1.4.1.9839.1.2.224.0 condenser-dirty-Rate OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Condenser-dirty-rate" ::= { snmpVariables 224 } -- 1.3.6.1.4.1.9839.1.2.225.0 inputsMng-SwLogic-Smoke OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Smoke-Fire-Alarm-Input-Logic-NC-0-NO-1" ::= { snmpVariables 225 } -- 1.3.6.1.4.1.9839.1.2.226.0 inputsMng-SwLogic-OvldComp OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 226 } -- 1.3.6.1.4.1.9839.1.2.227.0 inputsMng-SwLogic-PstatHiP OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 227 } -- 1.3.6.1.4.1.9839.1.2.228.0 inputsMng-SwLogic-PwrFail OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {TRUE} ::= { snmpVariables 228 } -- 1.3.6.1.4.1.9839.1.2.229.0 inputsMng-SwVal-Filt OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 229 } -- 1.3.6.1.4.1.9839.1.2.230.0 inputsMng-SwLogic-OvldSupplyFan OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 230 } -- 1.3.6.1.4.1.9839.1.2.231.0 onOffUnitMng-BmsOnOff OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Turn-System-On-Off-by-BMS-1-turn-on-0-turn-off-" DEFVAL {TRUE} ::= { snmpVariables 231 } -- 1.3.6.1.4.1.9839.1.2.232.0 en-Dehum OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Enable-dehumidification-This-is-a-master-switch-for-dehumidification-Each-individual-unit-can-be-set-to-allow-or-disallow-dehumidification-if-equipped-with-dehumidification-function-Default-FALSE-0" ::= { snmpVariables 232 } -- 1.3.6.1.4.1.9839.1.2.233.0 en-EmergVentilation OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Enable-emergency-ventilation-function-Emergency-ventilation-automatically-triggers-when-room-temperature-rises-above-emergency-ventilation-setpoint-and-bypasses-humidity-dust-requirement-and-reduce-minimum-temperature-differential-to-0-1F-Compressors-will-still-operate-during-emergency-ventilation-if-they-are-not-locked-out-Default-TRUE-1" DEFVAL {TRUE} ::= { snmpVariables 233 } -- 1.3.6.1.4.1.9839.1.2.234.0 en-SeaSideMode OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Enable-sea-side-coastal-mode-Only-allow-free-cooling-during-emergency-ventilation-to-minimize-outside-air-penetration-Default-False-0" DEFVAL {FALSE} ::= { snmpVariables 234 } -- 1.3.6.1.4.1.9839.1.2.235.0 alarmMng-En-Dust OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Enable-dust-detection-When-dust-is-detected-the-fresh-air-damper-will-close-for-a-set-time-Default-TRUE-1" DEFVAL {TRUE} ::= { snmpVariables 235 } -- 1.3.6.1.4.1.9839.1.2.236.0 comfortRun OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Turn-Comfort-Mode-On-Off-by-BMS-1-turn-on-0-turn-off" ::= { snmpVariables 236 } -- 1.3.6.1.4.1.9839.1.2.237.0 en-FC-LimHum OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Enable-humidity-limit-during-free-cooling-Free-cooling-will-stop-if-humidity-is-high-if-this-function-is-enabled-Default-TRUE-1" ::= { snmpVariables 237 } -- 1.3.6.1.4.1.9839.1.2.238.0 condensingFan-En-WipeSnow OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Enable-wipe-snow-function-Default-FALSE-0" ::= { snmpVariables 238 } -- 1.3.6.1.4.1.9839.1.2.239.0 coolHeatDemand OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Cooling-heating-command-Default-Cooling-FALSE-0-unless-heating-is-required" ::= { snmpVariables 239 } -- 1.3.6.1.4.1.9839.1.2.240.0 comp-En-RunFrmMaster OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" DEFVAL {TRUE} ::= { snmpVariables 240 } -- 1.3.6.1.4.1.9839.1.2.241.0 dehumSignal OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 241 } -- 1.3.6.1.4.1.9839.1.2.242.0 fC-LimHum-Signal OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Freecooling-humidity-limit-status-0-FC-currently-not-disabled-by-humidity-1-FC-Disabled-by-high-humidity" ::= { snmpVariables 242 } -- 1.3.6.1.4.1.9839.1.2.243.0 en-OilRecov OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {TRUE} ::= { snmpVariables 243 } -- 1.3.6.1.4.1.9839.1.2.244.0 alarmMng-AlrmResByBms OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm-reset-by-BMS-1-reset-Clears-all-active-alarms-and-lockouts-Alarm-will-return-if-alarm-condition-is-still-present-after-reset-" ::= { snmpVariables 244 } -- 1.3.6.1.4.1.9839.1.2.245.0 en-WipeMem OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Wipe-memory-Restore-all-changed-parameters-to-defaults-Change-this-parameter-to-1-to-restore-default-" ::= { snmpVariables 245 } -- 1.3.6.1.4.1.9839.1.2.246.0 alarmMng-En-Filter OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Enable-filter-alarm-Default-TRUE-1" DEFVAL {TRUE} ::= { snmpVariables 246 } -- 1.3.6.1.4.1.9839.1.2.247.0 condensingFan-En-HP-Zone OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {TRUE} ::= { snmpVariables 247 } -- 1.3.6.1.4.1.9839.1.2.248.0 exBoard-EU-En-ExBoard-EEV-EU OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" DEFVAL {TRUE} ::= { snmpVariables 248 } -- 1.3.6.1.4.1.9839.1.2.249.0 outputs-DoutLogic-ExhaustDamper OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 249 } -- 1.3.6.1.4.1.9839.1.2.250.0 alrmAmbHumPrb-Backup OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 250 } -- 1.3.6.1.4.1.9839.1.2.251.0 en-CompSpeed-limit-By-DG OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Enable-compressor-speed-limit-while-generator-is-running-Default-TRUE-1" DEFVAL {TRUE} ::= { snmpVariables 251 } -- 1.3.6.1.4.1.9839.1.2.252.0 en-FC-limit-By-DG OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Disable-free-cooling-while-generator-is-running-Default-False-0" DEFVAL {FALSE} ::= { snmpVariables 252 } -- 1.3.6.1.4.1.9839.1.2.253.0 condenser-Dirty-Enable OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-write STATUS current DESCRIPTION "Enable-dirty-condenser-alarm-Default-TRUE-1" DEFVAL {TRUE} ::= { snmpVariables 253 } -- 1.3.6.1.4.1.9839.1.2.254.0 unitOn OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Unit-On-status-TRUE-Unit-ON-in-automatic-mode-If-monitoring-the-controller-through-SNMP-this-refers-to-the-main-controller-" ::= { snmpVariables 254 } -- 1.3.6.1.4.1.9839.1.2.255.0 alarmMng-FC-Fault OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 255 } -- 1.3.6.1.4.1.9839.1.2.256.0 alrmOnOff OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Unit-On-Off-by-alarms-If-monitoring-the-controller-through-SNMP-this-refers-to-the-main-controller-" ::= { snmpVariables 256 } -- 1.3.6.1.4.1.9839.1.2.257.0 unit-Auto OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 257 } -- 1.3.6.1.4.1.9839.1.2.258.0 seriousAlarm-BLDC OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 258 } -- 1.3.6.1.4.1.9839.1.2.259.0 bLDC-Mng-Info-BLDC1-Mng-TestMode OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 259 } -- 1.3.6.1.4.1.9839.1.2.260.0 bLDC-Mng-Info-BLDC1-Info-SIAM-90rpsZone OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 260 } -- 1.3.6.1.4.1.9839.1.2.261.0 bLDC-Mng-Info-BLDC1-UI-EqualizationStatus OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 261 } -- 1.3.6.1.4.1.9839.1.2.262.0 bLDC-Mng-Info-BLDC1-UI-LowDeltaP OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 262 } -- 1.3.6.1.4.1.9839.1.2.263.0 dI-DG-Run OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Generator-Input-Status-0-normal-1-active" ::= { snmpVariables 263 } -- 1.3.6.1.4.1.9839.1.2.264.0 dI-Hydric OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Hydrogen-Input-Status-0-normal-1-active" ::= { snmpVariables 264 } -- 1.3.6.1.4.1.9839.1.2.265.0 dI-Smoke OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Smoke-Fire-alarm-0-normal-1-active" ::= { snmpVariables 265 } -- 1.3.6.1.4.1.9839.1.2.266.0 dI-OvldComp OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Compressor-Overload-Alarm-0-normal-1-active" ::= { snmpVariables 266 } -- 1.3.6.1.4.1.9839.1.2.267.0 dI-HiPSwitch OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-High-pressure-alarm-0-normal-1-active" ::= { snmpVariables 267 } -- 1.3.6.1.4.1.9839.1.2.268.0 dI-AC-Fail OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-AC-power-loss-alarm-0-normal-1-active" ::= { snmpVariables 268 } -- 1.3.6.1.4.1.9839.1.2.269.0 dI-Filt OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Filter-alarm-0-normal-1-active" ::= { snmpVariables 269 } -- 1.3.6.1.4.1.9839.1.2.270.0 dI-OvldSupplyFan OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Fan-Overload-alarm-0-normal-1-active" ::= { snmpVariables 270 } -- 1.3.6.1.4.1.9839.1.2.271.0 dI-AFPD OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "-Standalone-HVAC-Fan-Overload-alarm-0-normal-1-active" ::= { snmpVariables 271 } -- 1.3.6.1.4.1.9839.1.2.272.0 dI-PwrFail OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "DC-Failover-Active-0-normal-1-active" ::= { snmpVariables 272 } -- 1.3.6.1.4.1.9839.1.2.273.0 outputs-Dout1-Val OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Digital-Output-1-High-Low-Temperature-NO-dry-contact-0-normal-1-active" ::= { snmpVariables 273 } -- 1.3.6.1.4.1.9839.1.2.274.0 outputs-Dout2-Val OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Digital-Output-2-High-Low-Temperature-NC-dry-contact-0-active-1-normal" ::= { snmpVariables 274 } -- 1.3.6.1.4.1.9839.1.2.275.0 outputs-Dout3-Val OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Digital-Output-3-HVAC-1-Alarm-NO-dry-contact-0-normal-1-active" ::= { snmpVariables 275 } -- 1.3.6.1.4.1.9839.1.2.276.0 outputs-Dout4-Val OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Digital-Output-4-HVAC-2-Alarm-NO-dry-contact-0-normal-1-active" ::= { snmpVariables 276 } -- 1.3.6.1.4.1.9839.1.2.277.0 outputs-Dout5-Val OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Digital-Output-5-HVAC-3-Alarm-NO-dry-contact-0-normal-1-active" ::= { snmpVariables 277 } -- 1.3.6.1.4.1.9839.1.2.278.0 outputs-Dout6-Val OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Digital-Output-6-HVAC-Filter-Alarm-dry-contact-0-normal-1-active" ::= { snmpVariables 278 } -- 1.3.6.1.4.1.9839.1.2.279.0 conden-Temp-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 279 } -- 1.3.6.1.4.1.9839.1.2.280.0 conden-Temp-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 280 } -- 1.3.6.1.4.1.9839.1.2.281.0 conden-Temp-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 281 } -- 1.3.6.1.4.1.9839.1.2.282.0 conden-Temp-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 282 } -- 1.3.6.1.4.1.9839.1.2.283.0 conden-Temp-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 283 } -- 1.3.6.1.4.1.9839.1.2.284.0 conden-Temp-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 284 } -- 1.3.6.1.4.1.9839.1.2.285.0 conden-Temp-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 285 } -- 1.3.6.1.4.1.9839.1.2.286.0 conden-Temp-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 286 } -- 1.3.6.1.4.1.9839.1.2.287.0 conden-Temp-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 287 } -- 1.3.6.1.4.1.9839.1.2.288.0 conden-Temp-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 288 } -- 1.3.6.1.4.1.9839.1.2.289.0 conden-Temp-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 289 } -- 1.3.6.1.4.1.9839.1.2.290.0 conden-Temp-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 290 } -- 1.3.6.1.4.1.9839.1.2.291.0 conden-Temp-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 291 } -- 1.3.6.1.4.1.9839.1.2.292.0 conden-Temp-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 292 } -- 1.3.6.1.4.1.9839.1.2.293.0 conden-Temp-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 293 } -- 1.3.6.1.4.1.9839.1.2.294.0 conden-Temp-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Condensing-Temperature-Located-at-condenser-outlet-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 294 } -- 1.3.6.1.4.1.9839.1.2.295.0 room-Temp-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" DEFVAL {30} ::= { snmpVariables 295 } -- 1.3.6.1.4.1.9839.1.2.296.0 room-Temp-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" DEFVAL {30} ::= { snmpVariables 296 } -- 1.3.6.1.4.1.9839.1.2.297.0 room-Temp-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" DEFVAL {30} ::= { snmpVariables 297 } -- 1.3.6.1.4.1.9839.1.2.298.0 room-Temp-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 298 } -- 1.3.6.1.4.1.9839.1.2.299.0 room-Temp-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 299 } -- 1.3.6.1.4.1.9839.1.2.300.0 room-Temp-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 300 } -- 1.3.6.1.4.1.9839.1.2.301.0 room-Temp-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 301 } -- 1.3.6.1.4.1.9839.1.2.302.0 room-Temp-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 302 } -- 1.3.6.1.4.1.9839.1.2.303.0 room-Temp-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 303 } -- 1.3.6.1.4.1.9839.1.2.304.0 room-Temp-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 304 } -- 1.3.6.1.4.1.9839.1.2.305.0 room-Temp-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 305 } -- 1.3.6.1.4.1.9839.1.2.306.0 room-Temp-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 306 } -- 1.3.6.1.4.1.9839.1.2.307.0 room-Temp-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 307 } -- 1.3.6.1.4.1.9839.1.2.308.0 room-Temp-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 308 } -- 1.3.6.1.4.1.9839.1.2.309.0 room-Temp-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 309 } -- 1.3.6.1.4.1.9839.1.2.310.0 room-Temp-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Return-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 310 } -- 1.3.6.1.4.1.9839.1.2.311.0 ambHum-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Outdoor-Humidity-0-1-" ::= { snmpVariables 311 } -- 1.3.6.1.4.1.9839.1.2.312.0 ambHum-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Outdoor-Humidity-0-1-" ::= { snmpVariables 312 } -- 1.3.6.1.4.1.9839.1.2.313.0 ambHum-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Outdoor-Humidity-0-1-" ::= { snmpVariables 313 } -- 1.3.6.1.4.1.9839.1.2.314.0 ambHum-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Outdoor-Humidity-0-1-" ::= { snmpVariables 314 } -- 1.3.6.1.4.1.9839.1.2.315.0 ambHum-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Outdoor-Humidity-0-1-" ::= { snmpVariables 315 } -- 1.3.6.1.4.1.9839.1.2.316.0 ambHum-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Outdoor-Humidity-0-1-" ::= { snmpVariables 316 } -- 1.3.6.1.4.1.9839.1.2.317.0 ambHum-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Outdoor-Humidity-0-1-" ::= { snmpVariables 317 } -- 1.3.6.1.4.1.9839.1.2.318.0 ambHum-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Outdoor-Humidity-0-1-" ::= { snmpVariables 318 } -- 1.3.6.1.4.1.9839.1.2.319.0 ambHum-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Outdoor-Humidity-0-1-" ::= { snmpVariables 319 } -- 1.3.6.1.4.1.9839.1.2.320.0 ambHum-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Outdoor-Humidity-0-1-" ::= { snmpVariables 320 } -- 1.3.6.1.4.1.9839.1.2.321.0 ambHum-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Outdoor-Humidity-0-1-" ::= { snmpVariables 321 } -- 1.3.6.1.4.1.9839.1.2.322.0 ambHum-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Outdoor-Humidity-0-1-" ::= { snmpVariables 322 } -- 1.3.6.1.4.1.9839.1.2.323.0 ambHum-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Outdoor-Humidity-0-1-" ::= { snmpVariables 323 } -- 1.3.6.1.4.1.9839.1.2.324.0 ambHum-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Outdoor-Humidity-0-1-" ::= { snmpVariables 324 } -- 1.3.6.1.4.1.9839.1.2.325.0 ambHum-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Outdoor-Humidity-0-1-" ::= { snmpVariables 325 } -- 1.3.6.1.4.1.9839.1.2.326.0 ambHum-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Outdoor-Humidity-0-1-" ::= { snmpVariables 326 } -- 1.3.6.1.4.1.9839.1.2.327.0 ambTemp-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" DEFVAL {20} ::= { snmpVariables 327 } -- 1.3.6.1.4.1.9839.1.2.328.0 ambTemp-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" DEFVAL {20} ::= { snmpVariables 328 } -- 1.3.6.1.4.1.9839.1.2.329.0 ambTemp-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" DEFVAL {20} ::= { snmpVariables 329 } -- 1.3.6.1.4.1.9839.1.2.330.0 ambTemp-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 330 } -- 1.3.6.1.4.1.9839.1.2.331.0 ambTemp-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 331 } -- 1.3.6.1.4.1.9839.1.2.332.0 ambTemp-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 332 } -- 1.3.6.1.4.1.9839.1.2.333.0 ambTemp-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 333 } -- 1.3.6.1.4.1.9839.1.2.334.0 ambTemp-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 334 } -- 1.3.6.1.4.1.9839.1.2.335.0 ambTemp-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 335 } -- 1.3.6.1.4.1.9839.1.2.336.0 ambTemp-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 336 } -- 1.3.6.1.4.1.9839.1.2.337.0 ambTemp-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 337 } -- 1.3.6.1.4.1.9839.1.2.338.0 ambTemp-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 338 } -- 1.3.6.1.4.1.9839.1.2.339.0 ambTemp-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 339 } -- 1.3.6.1.4.1.9839.1.2.340.0 ambTemp-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 340 } -- 1.3.6.1.4.1.9839.1.2.341.0 ambTemp-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 341 } -- 1.3.6.1.4.1.9839.1.2.342.0 ambTemp-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Outdoor-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 342 } -- 1.3.6.1.4.1.9839.1.2.343.0 highPress-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 343 } -- 1.3.6.1.4.1.9839.1.2.344.0 highPress-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 344 } -- 1.3.6.1.4.1.9839.1.2.345.0 highPress-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 345 } -- 1.3.6.1.4.1.9839.1.2.346.0 highPress-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 346 } -- 1.3.6.1.4.1.9839.1.2.347.0 highPress-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 347 } -- 1.3.6.1.4.1.9839.1.2.348.0 highPress-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 348 } -- 1.3.6.1.4.1.9839.1.2.349.0 highPress-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 349 } -- 1.3.6.1.4.1.9839.1.2.350.0 highPress-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 350 } -- 1.3.6.1.4.1.9839.1.2.351.0 highPress-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 351 } -- 1.3.6.1.4.1.9839.1.2.352.0 highPress-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 352 } -- 1.3.6.1.4.1.9839.1.2.353.0 highPress-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 353 } -- 1.3.6.1.4.1.9839.1.2.354.0 highPress-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 354 } -- 1.3.6.1.4.1.9839.1.2.355.0 highPress-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 355 } -- 1.3.6.1.4.1.9839.1.2.356.0 highPress-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 356 } -- 1.3.6.1.4.1.9839.1.2.357.0 highPress-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 357 } -- 1.3.6.1.4.1.9839.1.2.358.0 highPress-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-High-Side-Pressure-Discharge-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 358 } -- 1.3.6.1.4.1.9839.1.2.359.0 discTemp-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 359 } -- 1.3.6.1.4.1.9839.1.2.360.0 discTemp-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 360 } -- 1.3.6.1.4.1.9839.1.2.361.0 discTemp-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 361 } -- 1.3.6.1.4.1.9839.1.2.362.0 discTemp-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 362 } -- 1.3.6.1.4.1.9839.1.2.363.0 discTemp-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 363 } -- 1.3.6.1.4.1.9839.1.2.364.0 discTemp-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 364 } -- 1.3.6.1.4.1.9839.1.2.365.0 discTemp-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 365 } -- 1.3.6.1.4.1.9839.1.2.366.0 discTemp-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 366 } -- 1.3.6.1.4.1.9839.1.2.367.0 discTemp-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 367 } -- 1.3.6.1.4.1.9839.1.2.368.0 discTemp-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 368 } -- 1.3.6.1.4.1.9839.1.2.369.0 discTemp-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 369 } -- 1.3.6.1.4.1.9839.1.2.370.0 discTemp-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 370 } -- 1.3.6.1.4.1.9839.1.2.371.0 discTemp-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 371 } -- 1.3.6.1.4.1.9839.1.2.372.0 discTemp-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 372 } -- 1.3.6.1.4.1.9839.1.2.373.0 discTemp-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 373 } -- 1.3.6.1.4.1.9839.1.2.374.0 discTemp-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-High-Side-Temperature-Discharge-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 374 } -- 1.3.6.1.4.1.9839.1.2.375.0 suctPress-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 375 } -- 1.3.6.1.4.1.9839.1.2.376.0 suctPress-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 376 } -- 1.3.6.1.4.1.9839.1.2.377.0 suctPress-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 377 } -- 1.3.6.1.4.1.9839.1.2.378.0 suctPress-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 378 } -- 1.3.6.1.4.1.9839.1.2.379.0 suctPress-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 379 } -- 1.3.6.1.4.1.9839.1.2.380.0 suctPress-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 380 } -- 1.3.6.1.4.1.9839.1.2.381.0 suctPress-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 381 } -- 1.3.6.1.4.1.9839.1.2.382.0 suctPress-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 382 } -- 1.3.6.1.4.1.9839.1.2.383.0 suctPress-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 383 } -- 1.3.6.1.4.1.9839.1.2.384.0 suctPress-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 384 } -- 1.3.6.1.4.1.9839.1.2.385.0 suctPress-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 385 } -- 1.3.6.1.4.1.9839.1.2.386.0 suctPress-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 386 } -- 1.3.6.1.4.1.9839.1.2.387.0 suctPress-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 387 } -- 1.3.6.1.4.1.9839.1.2.388.0 suctPress-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 388 } -- 1.3.6.1.4.1.9839.1.2.389.0 suctPress-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 389 } -- 1.3.6.1.4.1.9839.1.2.390.0 suctPress-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Low-Side-Pressure-Suction-Pressure-Output-is-0-1Bar-or-0-1psi-depending-on-unit-of-measurement-setting" ::= { snmpVariables 390 } -- 1.3.6.1.4.1.9839.1.2.391.0 suctTemp-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 391 } -- 1.3.6.1.4.1.9839.1.2.392.0 suctTemp-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 392 } -- 1.3.6.1.4.1.9839.1.2.393.0 suctTemp-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 393 } -- 1.3.6.1.4.1.9839.1.2.394.0 suctTemp-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 394 } -- 1.3.6.1.4.1.9839.1.2.395.0 suctTemp-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 395 } -- 1.3.6.1.4.1.9839.1.2.396.0 suctTemp-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 396 } -- 1.3.6.1.4.1.9839.1.2.397.0 suctTemp-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 397 } -- 1.3.6.1.4.1.9839.1.2.398.0 suctTemp-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 398 } -- 1.3.6.1.4.1.9839.1.2.399.0 suctTemp-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 399 } -- 1.3.6.1.4.1.9839.1.2.400.0 suctTemp-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 400 } -- 1.3.6.1.4.1.9839.1.2.401.0 suctTemp-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 401 } -- 1.3.6.1.4.1.9839.1.2.402.0 suctTemp-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 402 } -- 1.3.6.1.4.1.9839.1.2.403.0 suctTemp-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 403 } -- 1.3.6.1.4.1.9839.1.2.404.0 suctTemp-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 404 } -- 1.3.6.1.4.1.9839.1.2.405.0 suctTemp-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 405 } -- 1.3.6.1.4.1.9839.1.2.406.0 suctTemp-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Low-Side-Temperature-Suction-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 406 } -- 1.3.6.1.4.1.9839.1.2.407.0 supplTemp-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 407 } -- 1.3.6.1.4.1.9839.1.2.408.0 supplTemp-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 408 } -- 1.3.6.1.4.1.9839.1.2.409.0 supplTemp-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 409 } -- 1.3.6.1.4.1.9839.1.2.410.0 supplTemp-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 410 } -- 1.3.6.1.4.1.9839.1.2.411.0 supplTemp-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 411 } -- 1.3.6.1.4.1.9839.1.2.412.0 supplTemp-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 412 } -- 1.3.6.1.4.1.9839.1.2.413.0 supplTemp-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 413 } -- 1.3.6.1.4.1.9839.1.2.414.0 supplTemp-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 414 } -- 1.3.6.1.4.1.9839.1.2.415.0 supplTemp-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 415 } -- 1.3.6.1.4.1.9839.1.2.416.0 supplTemp-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 416 } -- 1.3.6.1.4.1.9839.1.2.417.0 supplTemp-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 417 } -- 1.3.6.1.4.1.9839.1.2.418.0 supplTemp-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 418 } -- 1.3.6.1.4.1.9839.1.2.419.0 supplTemp-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 419 } -- 1.3.6.1.4.1.9839.1.2.420.0 supplTemp-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 420 } -- 1.3.6.1.4.1.9839.1.2.421.0 supplTemp-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 421 } -- 1.3.6.1.4.1.9839.1.2.422.0 supplTemp-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Supply-Temperature-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 422 } -- 1.3.6.1.4.1.9839.1.2.423.0 supplyFanSpeed-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Supply-Fan-Speed-0-1-" ::= { snmpVariables 423 } -- 1.3.6.1.4.1.9839.1.2.424.0 supplyFanSpeed-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Supply-Fan-Speed-0-1-" ::= { snmpVariables 424 } -- 1.3.6.1.4.1.9839.1.2.425.0 supplyFanSpeed-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Supply-Fan-Speed-0-1-" ::= { snmpVariables 425 } -- 1.3.6.1.4.1.9839.1.2.426.0 supplyFanSpeed-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Supply-Fan-Speed-0-1-" ::= { snmpVariables 426 } -- 1.3.6.1.4.1.9839.1.2.427.0 supplyFanSpeed-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Supply-Fan-Speed-0-1-" ::= { snmpVariables 427 } -- 1.3.6.1.4.1.9839.1.2.428.0 supplyFanSpeed-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Supply-Fan-Speed-0-1-" ::= { snmpVariables 428 } -- 1.3.6.1.4.1.9839.1.2.429.0 supplyFanSpeed-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Supply-Fan-Speed-0-1-" ::= { snmpVariables 429 } -- 1.3.6.1.4.1.9839.1.2.430.0 supplyFanSpeed-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Supply-Fan-Speed-0-1-" ::= { snmpVariables 430 } -- 1.3.6.1.4.1.9839.1.2.431.0 supplyFanSpeed-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Supply-Fan-Speed-0-1-" ::= { snmpVariables 431 } -- 1.3.6.1.4.1.9839.1.2.432.0 supplyFanSpeed-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Supply-Fan-Speed-0-1-" ::= { snmpVariables 432 } -- 1.3.6.1.4.1.9839.1.2.433.0 supplyFanSpeed-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Supply-Fan-Speed-0-1-" ::= { snmpVariables 433 } -- 1.3.6.1.4.1.9839.1.2.434.0 supplyFanSpeed-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Supply-Fan-Speed-0-1-" ::= { snmpVariables 434 } -- 1.3.6.1.4.1.9839.1.2.435.0 supplyFanSpeed-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Supply-Fan-Speed-0-1-" ::= { snmpVariables 435 } -- 1.3.6.1.4.1.9839.1.2.436.0 supplyFanSpeed-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Supply-Fan-Speed-0-1-" ::= { snmpVariables 436 } -- 1.3.6.1.4.1.9839.1.2.437.0 supplyFanSpeed-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Supply-Fan-Speed-0-1-" ::= { snmpVariables 437 } -- 1.3.6.1.4.1.9839.1.2.438.0 supplyFanSpeed-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Supply-Fan-Speed-0-1-" ::= { snmpVariables 438 } -- 1.3.6.1.4.1.9839.1.2.439.0 returnDamperPos-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 439 } -- 1.3.6.1.4.1.9839.1.2.440.0 returnDamperPos-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 440 } -- 1.3.6.1.4.1.9839.1.2.441.0 returnDamperPos-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 441 } -- 1.3.6.1.4.1.9839.1.2.442.0 returnDamperPos-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 442 } -- 1.3.6.1.4.1.9839.1.2.443.0 returnDamperPos-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 443 } -- 1.3.6.1.4.1.9839.1.2.444.0 returnDamperPos-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 444 } -- 1.3.6.1.4.1.9839.1.2.445.0 returnDamperPos-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 445 } -- 1.3.6.1.4.1.9839.1.2.446.0 returnDamperPos-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 446 } -- 1.3.6.1.4.1.9839.1.2.447.0 returnDamperPos-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 447 } -- 1.3.6.1.4.1.9839.1.2.448.0 returnDamperPos-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 448 } -- 1.3.6.1.4.1.9839.1.2.449.0 returnDamperPos-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 449 } -- 1.3.6.1.4.1.9839.1.2.450.0 returnDamperPos-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 450 } -- 1.3.6.1.4.1.9839.1.2.451.0 returnDamperPos-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 451 } -- 1.3.6.1.4.1.9839.1.2.452.0 returnDamperPos-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 452 } -- 1.3.6.1.4.1.9839.1.2.453.0 returnDamperPos-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 453 } -- 1.3.6.1.4.1.9839.1.2.454.0 returnDamperPos-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Free-Cooling-Damper-Position-0-1-" ::= { snmpVariables 454 } -- 1.3.6.1.4.1.9839.1.2.455.0 condFanSpeed-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 455 } -- 1.3.6.1.4.1.9839.1.2.456.0 condFanSpeed-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 456 } -- 1.3.6.1.4.1.9839.1.2.457.0 condFanSpeed-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 457 } -- 1.3.6.1.4.1.9839.1.2.458.0 condFanSpeed-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 458 } -- 1.3.6.1.4.1.9839.1.2.459.0 condFanSpeed-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 459 } -- 1.3.6.1.4.1.9839.1.2.460.0 condFanSpeed-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 460 } -- 1.3.6.1.4.1.9839.1.2.461.0 condFanSpeed-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 461 } -- 1.3.6.1.4.1.9839.1.2.462.0 condFanSpeed-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 462 } -- 1.3.6.1.4.1.9839.1.2.463.0 condFanSpeed-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 463 } -- 1.3.6.1.4.1.9839.1.2.464.0 condFanSpeed-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 464 } -- 1.3.6.1.4.1.9839.1.2.465.0 condFanSpeed-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 465 } -- 1.3.6.1.4.1.9839.1.2.466.0 condFanSpeed-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 466 } -- 1.3.6.1.4.1.9839.1.2.467.0 condFanSpeed-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 467 } -- 1.3.6.1.4.1.9839.1.2.468.0 condFanSpeed-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 468 } -- 1.3.6.1.4.1.9839.1.2.469.0 condFanSpeed-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 469 } -- 1.3.6.1.4.1.9839.1.2.470.0 condFanSpeed-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Condenser-Fan-Speed-0-1-" ::= { snmpVariables 470 } -- 1.3.6.1.4.1.9839.1.2.471.0 compSpeed-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Compressor-Speed-rps-" ::= { snmpVariables 471 } -- 1.3.6.1.4.1.9839.1.2.472.0 compSpeed-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Compressor-Speed-rps-" ::= { snmpVariables 472 } -- 1.3.6.1.4.1.9839.1.2.473.0 compSpeed-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Compressor-Speed-rps-" ::= { snmpVariables 473 } -- 1.3.6.1.4.1.9839.1.2.474.0 compSpeed-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Compressor-Speed-rps-" ::= { snmpVariables 474 } -- 1.3.6.1.4.1.9839.1.2.475.0 compSpeed-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Compressor-Speed-rps-" ::= { snmpVariables 475 } -- 1.3.6.1.4.1.9839.1.2.476.0 compSpeed-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Compressor-Speed-rps-" ::= { snmpVariables 476 } -- 1.3.6.1.4.1.9839.1.2.477.0 compSpeed-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Compressor-Speed-rps-" ::= { snmpVariables 477 } -- 1.3.6.1.4.1.9839.1.2.478.0 compSpeed-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Compressor-Speed-rps-" ::= { snmpVariables 478 } -- 1.3.6.1.4.1.9839.1.2.479.0 compSpeed-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Compressor-Speed-rps-" ::= { snmpVariables 479 } -- 1.3.6.1.4.1.9839.1.2.480.0 compSpeed-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Compressor-Speed-rps-" ::= { snmpVariables 480 } -- 1.3.6.1.4.1.9839.1.2.481.0 compSpeed-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Compressor-Speed-rps-" ::= { snmpVariables 481 } -- 1.3.6.1.4.1.9839.1.2.482.0 compSpeed-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Compressor-Speed-rps-" ::= { snmpVariables 482 } -- 1.3.6.1.4.1.9839.1.2.483.0 compSpeed-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Compressor-Speed-rps-" ::= { snmpVariables 483 } -- 1.3.6.1.4.1.9839.1.2.484.0 compSpeed-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Compressor-Speed-rps-" ::= { snmpVariables 484 } -- 1.3.6.1.4.1.9839.1.2.485.0 compSpeed-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Compressor-Speed-rps-" ::= { snmpVariables 485 } -- 1.3.6.1.4.1.9839.1.2.486.0 compSpeed-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Compressor-Speed-rps-" ::= { snmpVariables 486 } -- 1.3.6.1.4.1.9839.1.2.487.0 valve-Open-Pos-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-EEV-Position-0-1-" ::= { snmpVariables 487 } -- 1.3.6.1.4.1.9839.1.2.488.0 valve-Open-Pos-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-EEV-Position-0-1-" ::= { snmpVariables 488 } -- 1.3.6.1.4.1.9839.1.2.489.0 valve-Open-Pos-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-EEV-Position-0-1-" ::= { snmpVariables 489 } -- 1.3.6.1.4.1.9839.1.2.490.0 valve-Open-Pos-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-EEV-Position-0-1-" ::= { snmpVariables 490 } -- 1.3.6.1.4.1.9839.1.2.491.0 valve-Open-Pos-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-EEV-Position-0-1-" ::= { snmpVariables 491 } -- 1.3.6.1.4.1.9839.1.2.492.0 valve-Open-Pos-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-EEV-Position-0-1-" ::= { snmpVariables 492 } -- 1.3.6.1.4.1.9839.1.2.493.0 valve-Open-Pos-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-EEV-Position-0-1-" ::= { snmpVariables 493 } -- 1.3.6.1.4.1.9839.1.2.494.0 valve-Open-Pos-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-EEV-Position-0-1-" ::= { snmpVariables 494 } -- 1.3.6.1.4.1.9839.1.2.495.0 valve-Open-Pos-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-EEV-Position-0-1-" ::= { snmpVariables 495 } -- 1.3.6.1.4.1.9839.1.2.496.0 valve-Open-Pos-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-EEV-Position-0-1-" ::= { snmpVariables 496 } -- 1.3.6.1.4.1.9839.1.2.497.0 valve-Open-Pos-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-EEV-Position-0-1-" ::= { snmpVariables 497 } -- 1.3.6.1.4.1.9839.1.2.498.0 valve-Open-Pos-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-EEV-Position-0-1-" ::= { snmpVariables 498 } -- 1.3.6.1.4.1.9839.1.2.499.0 valve-Open-Pos-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-EEV-Position-0-1-" ::= { snmpVariables 499 } -- 1.3.6.1.4.1.9839.1.2.500.0 valve-Open-Pos-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-EEV-Position-0-1-" ::= { snmpVariables 500 } -- 1.3.6.1.4.1.9839.1.2.501.0 valve-Open-Pos-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-EEV-Position-0-1-" ::= { snmpVariables 501 } -- 1.3.6.1.4.1.9839.1.2.502.0 valve-Open-Pos-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-EEV-Position-0-1-" ::= { snmpVariables 502 } -- 1.3.6.1.4.1.9839.1.2.503.0 sH-Cond-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 503 } -- 1.3.6.1.4.1.9839.1.2.504.0 sH-Cond-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 504 } -- 1.3.6.1.4.1.9839.1.2.505.0 sH-Cond-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 505 } -- 1.3.6.1.4.1.9839.1.2.506.0 sH-Cond-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 506 } -- 1.3.6.1.4.1.9839.1.2.507.0 sH-Cond-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 507 } -- 1.3.6.1.4.1.9839.1.2.508.0 sH-Cond-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 508 } -- 1.3.6.1.4.1.9839.1.2.509.0 sH-Cond-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 509 } -- 1.3.6.1.4.1.9839.1.2.510.0 sH-Cond-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 510 } -- 1.3.6.1.4.1.9839.1.2.511.0 sH-Cond-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 511 } -- 1.3.6.1.4.1.9839.1.2.512.0 sH-Cond-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 512 } -- 1.3.6.1.4.1.9839.1.2.513.0 sH-Cond-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 513 } -- 1.3.6.1.4.1.9839.1.2.514.0 sH-Cond-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 514 } -- 1.3.6.1.4.1.9839.1.2.515.0 sH-Cond-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 515 } -- 1.3.6.1.4.1.9839.1.2.516.0 sH-Cond-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 516 } -- 1.3.6.1.4.1.9839.1.2.517.0 sH-Cond-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 517 } -- 1.3.6.1.4.1.9839.1.2.518.0 sH-Cond-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Subcooling-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 518 } -- 1.3.6.1.4.1.9839.1.2.519.0 sH-Evap-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 519 } -- 1.3.6.1.4.1.9839.1.2.520.0 sH-Evap-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 520 } -- 1.3.6.1.4.1.9839.1.2.521.0 sH-Evap-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 521 } -- 1.3.6.1.4.1.9839.1.2.522.0 sH-Evap-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 522 } -- 1.3.6.1.4.1.9839.1.2.523.0 sH-Evap-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 523 } -- 1.3.6.1.4.1.9839.1.2.524.0 sH-Evap-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 524 } -- 1.3.6.1.4.1.9839.1.2.525.0 sH-Evap-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 525 } -- 1.3.6.1.4.1.9839.1.2.526.0 sH-Evap-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 526 } -- 1.3.6.1.4.1.9839.1.2.527.0 sH-Evap-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 527 } -- 1.3.6.1.4.1.9839.1.2.528.0 sH-Evap-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 528 } -- 1.3.6.1.4.1.9839.1.2.529.0 sH-Evap-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 529 } -- 1.3.6.1.4.1.9839.1.2.530.0 sH-Evap-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 530 } -- 1.3.6.1.4.1.9839.1.2.531.0 sH-Evap-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 531 } -- 1.3.6.1.4.1.9839.1.2.532.0 sH-Evap-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 532 } -- 1.3.6.1.4.1.9839.1.2.533.0 sH-Evap-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 533 } -- 1.3.6.1.4.1.9839.1.2.534.0 sH-Evap-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Super-Heat-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting-Output-is-0-1C-or-0-1F-depending-on-unit-of-measurement-setting" ::= { snmpVariables 534 } -- 1.3.6.1.4.1.9839.1.2.535.0 filter-Air-Press-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 535 } -- 1.3.6.1.4.1.9839.1.2.536.0 filter-Air-Press-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 536 } -- 1.3.6.1.4.1.9839.1.2.537.0 filter-Air-Press-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 537 } -- 1.3.6.1.4.1.9839.1.2.538.0 filter-Air-Press-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 538 } -- 1.3.6.1.4.1.9839.1.2.539.0 filter-Air-Press-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 539 } -- 1.3.6.1.4.1.9839.1.2.540.0 filter-Air-Press-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 540 } -- 1.3.6.1.4.1.9839.1.2.541.0 filter-Air-Press-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 541 } -- 1.3.6.1.4.1.9839.1.2.542.0 filter-Air-Press-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 542 } -- 1.3.6.1.4.1.9839.1.2.543.0 filter-Air-Press-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 543 } -- 1.3.6.1.4.1.9839.1.2.544.0 filter-Air-Press-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 544 } -- 1.3.6.1.4.1.9839.1.2.545.0 filter-Air-Press-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 545 } -- 1.3.6.1.4.1.9839.1.2.546.0 filter-Air-Press-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 546 } -- 1.3.6.1.4.1.9839.1.2.547.0 filter-Air-Press-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 547 } -- 1.3.6.1.4.1.9839.1.2.548.0 filter-Air-Press-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 548 } -- 1.3.6.1.4.1.9839.1.2.549.0 filter-Air-Press-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 549 } -- 1.3.6.1.4.1.9839.1.2.550.0 filter-Air-Press-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Filter-Air-pressure-Only-applicable-when-optional-filter-sensor-is-installed-Output-in-0-1kPA" ::= { snmpVariables 550 } -- 1.3.6.1.4.1.9839.1.2.551.0 temp-Power-S-List-0- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Instantaneous-Power-In-kW" ::= { snmpVariables 551 } -- 1.3.6.1.4.1.9839.1.2.552.0 temp-Power-S-List-1- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Instantaneous-Power-In-kW" ::= { snmpVariables 552 } -- 1.3.6.1.4.1.9839.1.2.553.0 temp-Power-S-List-2- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Instantaneous-Power-In-kW" ::= { snmpVariables 553 } -- 1.3.6.1.4.1.9839.1.2.554.0 temp-Power-S-List-3- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Instantaneous-Power-In-kW" ::= { snmpVariables 554 } -- 1.3.6.1.4.1.9839.1.2.555.0 temp-Power-S-List-4- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Instantaneous-Power-In-kW" ::= { snmpVariables 555 } -- 1.3.6.1.4.1.9839.1.2.556.0 temp-Power-S-List-5- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Instantaneous-Power-In-kW" ::= { snmpVariables 556 } -- 1.3.6.1.4.1.9839.1.2.557.0 temp-Power-S-List-6- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Instantaneous-Power-In-kW" ::= { snmpVariables 557 } -- 1.3.6.1.4.1.9839.1.2.558.0 temp-Power-S-List-7- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Instantaneous-Power-In-kW" ::= { snmpVariables 558 } -- 1.3.6.1.4.1.9839.1.2.559.0 temp-Power-S-List-8- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Instantaneous-Power-In-kW" ::= { snmpVariables 559 } -- 1.3.6.1.4.1.9839.1.2.560.0 temp-Power-S-List-9- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Instantaneous-Power-In-kW" ::= { snmpVariables 560 } -- 1.3.6.1.4.1.9839.1.2.561.0 temp-Power-S-List-10- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Instantaneous-Power-In-kW" ::= { snmpVariables 561 } -- 1.3.6.1.4.1.9839.1.2.562.0 temp-Power-S-List-11- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Instantaneous-Power-In-kW" ::= { snmpVariables 562 } -- 1.3.6.1.4.1.9839.1.2.563.0 temp-Power-S-List-12- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Instantaneous-Power-In-kW" ::= { snmpVariables 563 } -- 1.3.6.1.4.1.9839.1.2.564.0 temp-Power-S-List-13- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Instantaneous-Power-In-kW" ::= { snmpVariables 564 } -- 1.3.6.1.4.1.9839.1.2.565.0 temp-Power-S-List-14- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Instantaneous-Power-In-kW" ::= { snmpVariables 565 } -- 1.3.6.1.4.1.9839.1.2.566.0 temp-Power-S-List-15- OBJECT-TYPE SYNTAX Float MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Instantaneous-Power-In-kW" ::= { snmpVariables 566 } -- 1.3.6.1.4.1.9839.1.2.567.0 dI-Smoke-List-0- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 567 } -- 1.3.6.1.4.1.9839.1.2.568.0 dI-Smoke-List-1- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 568 } -- 1.3.6.1.4.1.9839.1.2.569.0 dI-Smoke-List-2- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 569 } -- 1.3.6.1.4.1.9839.1.2.570.0 dI-Smoke-List-3- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 570 } -- 1.3.6.1.4.1.9839.1.2.571.0 dI-Smoke-List-4- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 571 } -- 1.3.6.1.4.1.9839.1.2.572.0 dI-Smoke-List-5- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 572 } -- 1.3.6.1.4.1.9839.1.2.573.0 dI-Smoke-List-6- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 573 } -- 1.3.6.1.4.1.9839.1.2.574.0 dI-Smoke-List-7- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 574 } -- 1.3.6.1.4.1.9839.1.2.575.0 dI-Smoke-List-8- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 575 } -- 1.3.6.1.4.1.9839.1.2.576.0 dI-Smoke-List-9- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 576 } -- 1.3.6.1.4.1.9839.1.2.577.0 dI-Smoke-List-10- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 577 } -- 1.3.6.1.4.1.9839.1.2.578.0 dI-Smoke-List-11- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 578 } -- 1.3.6.1.4.1.9839.1.2.579.0 dI-Smoke-List-12- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 579 } -- 1.3.6.1.4.1.9839.1.2.580.0 dI-Smoke-List-13- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 580 } -- 1.3.6.1.4.1.9839.1.2.581.0 dI-Smoke-List-14- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 581 } -- 1.3.6.1.4.1.9839.1.2.582.0 dI-Smoke-List-15- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Smoke-Fire-Alarm-Input-0-normal-1-active" ::= { snmpVariables 582 } -- 1.3.6.1.4.1.9839.1.2.583.0 dI-CompOvload-List-0- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 583 } -- 1.3.6.1.4.1.9839.1.2.584.0 dI-CompOvload-List-1- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 584 } -- 1.3.6.1.4.1.9839.1.2.585.0 dI-CompOvload-List-2- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 585 } -- 1.3.6.1.4.1.9839.1.2.586.0 dI-CompOvload-List-3- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 586 } -- 1.3.6.1.4.1.9839.1.2.587.0 dI-CompOvload-List-4- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 587 } -- 1.3.6.1.4.1.9839.1.2.588.0 dI-CompOvload-List-5- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 588 } -- 1.3.6.1.4.1.9839.1.2.589.0 dI-CompOvload-List-6- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 589 } -- 1.3.6.1.4.1.9839.1.2.590.0 dI-CompOvload-List-7- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 590 } -- 1.3.6.1.4.1.9839.1.2.591.0 dI-CompOvload-List-8- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 591 } -- 1.3.6.1.4.1.9839.1.2.592.0 dI-CompOvload-List-9- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 592 } -- 1.3.6.1.4.1.9839.1.2.593.0 dI-CompOvload-List-10- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 593 } -- 1.3.6.1.4.1.9839.1.2.594.0 dI-CompOvload-List-11- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 594 } -- 1.3.6.1.4.1.9839.1.2.595.0 dI-CompOvload-List-12- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 595 } -- 1.3.6.1.4.1.9839.1.2.596.0 dI-CompOvload-List-13- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 596 } -- 1.3.6.1.4.1.9839.1.2.597.0 dI-CompOvload-List-14- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 597 } -- 1.3.6.1.4.1.9839.1.2.598.0 dI-CompOvload-List-15- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Compressor-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 598 } -- 1.3.6.1.4.1.9839.1.2.599.0 dI-HiPSwitch-List-0- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 599 } -- 1.3.6.1.4.1.9839.1.2.600.0 dI-HiPSwitch-List-1- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 600 } -- 1.3.6.1.4.1.9839.1.2.601.0 dI-HiPSwitch-List-2- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 601 } -- 1.3.6.1.4.1.9839.1.2.602.0 dI-HiPSwitch-List-3- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 602 } -- 1.3.6.1.4.1.9839.1.2.603.0 dI-HiPSwitch-List-4- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 603 } -- 1.3.6.1.4.1.9839.1.2.604.0 dI-HiPSwitch-List-5- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 604 } -- 1.3.6.1.4.1.9839.1.2.605.0 dI-HiPSwitch-List-6- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 605 } -- 1.3.6.1.4.1.9839.1.2.606.0 dI-HiPSwitch-List-7- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 606 } -- 1.3.6.1.4.1.9839.1.2.607.0 dI-HiPSwitch-List-8- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 607 } -- 1.3.6.1.4.1.9839.1.2.608.0 dI-HiPSwitch-List-9- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 608 } -- 1.3.6.1.4.1.9839.1.2.609.0 dI-HiPSwitch-List-10- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 609 } -- 1.3.6.1.4.1.9839.1.2.610.0 dI-HiPSwitch-List-11- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 610 } -- 1.3.6.1.4.1.9839.1.2.611.0 dI-HiPSwitch-List-12- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 611 } -- 1.3.6.1.4.1.9839.1.2.612.0 dI-HiPSwitch-List-13- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 612 } -- 1.3.6.1.4.1.9839.1.2.613.0 dI-HiPSwitch-List-14- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 613 } -- 1.3.6.1.4.1.9839.1.2.614.0 dI-HiPSwitch-List-15- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-High-Pressure-Switch-Alarm-Input-0-normal-1-active" ::= { snmpVariables 614 } -- 1.3.6.1.4.1.9839.1.2.615.0 dI-AC-Fail-List-0- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 615 } -- 1.3.6.1.4.1.9839.1.2.616.0 dI-AC-Fail-List-1- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 616 } -- 1.3.6.1.4.1.9839.1.2.617.0 dI-AC-Fail-List-2- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 617 } -- 1.3.6.1.4.1.9839.1.2.618.0 dI-AC-Fail-List-3- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 618 } -- 1.3.6.1.4.1.9839.1.2.619.0 dI-AC-Fail-List-4- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 619 } -- 1.3.6.1.4.1.9839.1.2.620.0 dI-AC-Fail-List-5- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 620 } -- 1.3.6.1.4.1.9839.1.2.621.0 dI-AC-Fail-List-6- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 621 } -- 1.3.6.1.4.1.9839.1.2.622.0 dI-AC-Fail-List-7- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 622 } -- 1.3.6.1.4.1.9839.1.2.623.0 dI-AC-Fail-List-8- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 623 } -- 1.3.6.1.4.1.9839.1.2.624.0 dI-AC-Fail-List-9- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 624 } -- 1.3.6.1.4.1.9839.1.2.625.0 dI-AC-Fail-List-10- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 625 } -- 1.3.6.1.4.1.9839.1.2.626.0 dI-AC-Fail-List-11- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 626 } -- 1.3.6.1.4.1.9839.1.2.627.0 dI-AC-Fail-List-12- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 627 } -- 1.3.6.1.4.1.9839.1.2.628.0 dI-AC-Fail-List-13- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 628 } -- 1.3.6.1.4.1.9839.1.2.629.0 dI-AC-Fail-List-14- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 629 } -- 1.3.6.1.4.1.9839.1.2.630.0 dI-AC-Fail-List-15- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-AC-Power-Fault-Alarm-Input-0-normal-1-active" ::= { snmpVariables 630 } -- 1.3.6.1.4.1.9839.1.2.631.0 dI-Filter-List-0- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 631 } -- 1.3.6.1.4.1.9839.1.2.632.0 dI-Filter-List-1- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 632 } -- 1.3.6.1.4.1.9839.1.2.633.0 dI-Filter-List-2- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 633 } -- 1.3.6.1.4.1.9839.1.2.634.0 dI-Filter-List-3- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 634 } -- 1.3.6.1.4.1.9839.1.2.635.0 dI-Filter-List-4- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 635 } -- 1.3.6.1.4.1.9839.1.2.636.0 dI-Filter-List-5- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 636 } -- 1.3.6.1.4.1.9839.1.2.637.0 dI-Filter-List-6- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 637 } -- 1.3.6.1.4.1.9839.1.2.638.0 dI-Filter-List-7- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 638 } -- 1.3.6.1.4.1.9839.1.2.639.0 dI-Filter-List-8- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 639 } -- 1.3.6.1.4.1.9839.1.2.640.0 dI-Filter-List-9- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 640 } -- 1.3.6.1.4.1.9839.1.2.641.0 dI-Filter-List-10- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 641 } -- 1.3.6.1.4.1.9839.1.2.642.0 dI-Filter-List-11- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 642 } -- 1.3.6.1.4.1.9839.1.2.643.0 dI-Filter-List-12- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 643 } -- 1.3.6.1.4.1.9839.1.2.644.0 dI-Filter-List-13- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 644 } -- 1.3.6.1.4.1.9839.1.2.645.0 dI-Filter-List-14- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 645 } -- 1.3.6.1.4.1.9839.1.2.646.0 dI-Filter-List-15- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Filter-Stuck-Alarm-Input-0-normal-1-active" ::= { snmpVariables 646 } -- 1.3.6.1.4.1.9839.1.2.647.0 dI-OvldSupplyFan-List-0- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 647 } -- 1.3.6.1.4.1.9839.1.2.648.0 dI-OvldSupplyFan-List-1- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 648 } -- 1.3.6.1.4.1.9839.1.2.649.0 dI-OvldSupplyFan-List-2- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 649 } -- 1.3.6.1.4.1.9839.1.2.650.0 dI-OvldSupplyFan-List-3- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 650 } -- 1.3.6.1.4.1.9839.1.2.651.0 dI-OvldSupplyFan-List-4- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 651 } -- 1.3.6.1.4.1.9839.1.2.652.0 dI-OvldSupplyFan-List-5- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 652 } -- 1.3.6.1.4.1.9839.1.2.653.0 dI-OvldSupplyFan-List-6- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 653 } -- 1.3.6.1.4.1.9839.1.2.654.0 dI-OvldSupplyFan-List-7- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 654 } -- 1.3.6.1.4.1.9839.1.2.655.0 dI-OvldSupplyFan-List-8- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 655 } -- 1.3.6.1.4.1.9839.1.2.656.0 dI-OvldSupplyFan-List-9- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 656 } -- 1.3.6.1.4.1.9839.1.2.657.0 dI-OvldSupplyFan-List-10- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 657 } -- 1.3.6.1.4.1.9839.1.2.658.0 dI-OvldSupplyFan-List-11- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 658 } -- 1.3.6.1.4.1.9839.1.2.659.0 dI-OvldSupplyFan-List-12- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 659 } -- 1.3.6.1.4.1.9839.1.2.660.0 dI-OvldSupplyFan-List-13- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 660 } -- 1.3.6.1.4.1.9839.1.2.661.0 dI-OvldSupplyFan-List-14- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 661 } -- 1.3.6.1.4.1.9839.1.2.662.0 dI-OvldSupplyFan-List-15- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Supply-Fan-Overload-Alarm-Input-0-normal-1-active" ::= { snmpVariables 662 } -- 1.3.6.1.4.1.9839.1.2.663.0 dI-AFPD-List-0- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 663 } -- 1.3.6.1.4.1.9839.1.2.664.0 dI-AFPD-List-1- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 664 } -- 1.3.6.1.4.1.9839.1.2.665.0 dI-AFPD-List-2- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 665 } -- 1.3.6.1.4.1.9839.1.2.666.0 dI-AFPD-List-3- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 666 } -- 1.3.6.1.4.1.9839.1.2.667.0 dI-AFPD-List-4- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 667 } -- 1.3.6.1.4.1.9839.1.2.668.0 dI-AFPD-List-5- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 668 } -- 1.3.6.1.4.1.9839.1.2.669.0 dI-AFPD-List-6- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 669 } -- 1.3.6.1.4.1.9839.1.2.670.0 dI-AFPD-List-7- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 670 } -- 1.3.6.1.4.1.9839.1.2.671.0 dI-AFPD-List-8- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 671 } -- 1.3.6.1.4.1.9839.1.2.672.0 dI-AFPD-List-9- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 672 } -- 1.3.6.1.4.1.9839.1.2.673.0 dI-AFPD-List-10- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 673 } -- 1.3.6.1.4.1.9839.1.2.674.0 dI-AFPD-List-11- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 674 } -- 1.3.6.1.4.1.9839.1.2.675.0 dI-AFPD-List-12- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 675 } -- 1.3.6.1.4.1.9839.1.2.676.0 dI-AFPD-List-13- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 676 } -- 1.3.6.1.4.1.9839.1.2.677.0 dI-AFPD-List-14- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 677 } -- 1.3.6.1.4.1.9839.1.2.678.0 dI-AFPD-List-15- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-AFPD-Alarm-Input-0-normal-1-active" ::= { snmpVariables 678 } -- 1.3.6.1.4.1.9839.1.2.679.0 dout1-List-0- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Compressor-Status-0-On-1-Off" ::= { snmpVariables 679 } -- 1.3.6.1.4.1.9839.1.2.680.0 dout1-List-1- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Compressor-Status-0-On-1-Off" ::= { snmpVariables 680 } -- 1.3.6.1.4.1.9839.1.2.681.0 dout1-List-2- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Compressor-Status-0-On-1-Off" ::= { snmpVariables 681 } -- 1.3.6.1.4.1.9839.1.2.682.0 dout1-List-3- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Compressor-Status-0-On-1-Off" ::= { snmpVariables 682 } -- 1.3.6.1.4.1.9839.1.2.683.0 dout1-List-4- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Compressor-Status-0-On-1-Off" ::= { snmpVariables 683 } -- 1.3.6.1.4.1.9839.1.2.684.0 dout1-List-5- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Compressor-Status-0-On-1-Off" ::= { snmpVariables 684 } -- 1.3.6.1.4.1.9839.1.2.685.0 dout1-List-6- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Compressor-Status-0-On-1-Off" ::= { snmpVariables 685 } -- 1.3.6.1.4.1.9839.1.2.686.0 dout1-List-7- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Compressor-Status-0-On-1-Off" ::= { snmpVariables 686 } -- 1.3.6.1.4.1.9839.1.2.687.0 dout1-List-8- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Compressor-Status-0-On-1-Off" ::= { snmpVariables 687 } -- 1.3.6.1.4.1.9839.1.2.688.0 dout1-List-9- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Compressor-Status-0-On-1-Off" ::= { snmpVariables 688 } -- 1.3.6.1.4.1.9839.1.2.689.0 dout1-List-10- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Compressor-Status-0-On-1-Off" ::= { snmpVariables 689 } -- 1.3.6.1.4.1.9839.1.2.690.0 dout1-List-11- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Compressor-Status-0-On-1-Off" ::= { snmpVariables 690 } -- 1.3.6.1.4.1.9839.1.2.691.0 dout1-List-12- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Compressor-Status-0-On-1-Off" ::= { snmpVariables 691 } -- 1.3.6.1.4.1.9839.1.2.692.0 dout1-List-13- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Compressor-Status-0-On-1-Off" ::= { snmpVariables 692 } -- 1.3.6.1.4.1.9839.1.2.693.0 dout1-List-14- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Compressor-Status-0-On-1-Off" ::= { snmpVariables 693 } -- 1.3.6.1.4.1.9839.1.2.694.0 dout1-List-15- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Compressor-Status-0-On-1-Off" ::= { snmpVariables 694 } -- 1.3.6.1.4.1.9839.1.2.695.0 dout2-List-0- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 695 } -- 1.3.6.1.4.1.9839.1.2.696.0 dout2-List-1- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 696 } -- 1.3.6.1.4.1.9839.1.2.697.0 dout2-List-2- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 697 } -- 1.3.6.1.4.1.9839.1.2.698.0 dout2-List-3- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 698 } -- 1.3.6.1.4.1.9839.1.2.699.0 dout2-List-4- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 699 } -- 1.3.6.1.4.1.9839.1.2.700.0 dout2-List-5- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 700 } -- 1.3.6.1.4.1.9839.1.2.701.0 dout2-List-6- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 701 } -- 1.3.6.1.4.1.9839.1.2.702.0 dout2-List-7- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 702 } -- 1.3.6.1.4.1.9839.1.2.703.0 dout2-List-8- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 703 } -- 1.3.6.1.4.1.9839.1.2.704.0 dout2-List-9- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 704 } -- 1.3.6.1.4.1.9839.1.2.705.0 dout2-List-10- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 705 } -- 1.3.6.1.4.1.9839.1.2.706.0 dout2-List-11- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 706 } -- 1.3.6.1.4.1.9839.1.2.707.0 dout2-List-12- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 707 } -- 1.3.6.1.4.1.9839.1.2.708.0 dout2-List-13- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 708 } -- 1.3.6.1.4.1.9839.1.2.709.0 dout2-List-14- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 709 } -- 1.3.6.1.4.1.9839.1.2.710.0 dout2-List-15- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Supply-Fan-Status-0-OFF-1-ON" ::= { snmpVariables 710 } -- 1.3.6.1.4.1.9839.1.2.711.0 dout3-List-0- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 711 } -- 1.3.6.1.4.1.9839.1.2.712.0 dout3-List-1- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 712 } -- 1.3.6.1.4.1.9839.1.2.713.0 dout3-List-2- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 713 } -- 1.3.6.1.4.1.9839.1.2.714.0 dout3-List-3- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 714 } -- 1.3.6.1.4.1.9839.1.2.715.0 dout3-List-4- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 715 } -- 1.3.6.1.4.1.9839.1.2.716.0 dout3-List-5- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 716 } -- 1.3.6.1.4.1.9839.1.2.717.0 dout3-List-6- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 717 } -- 1.3.6.1.4.1.9839.1.2.718.0 dout3-List-7- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 718 } -- 1.3.6.1.4.1.9839.1.2.719.0 dout3-List-8- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 719 } -- 1.3.6.1.4.1.9839.1.2.720.0 dout3-List-9- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 720 } -- 1.3.6.1.4.1.9839.1.2.721.0 dout3-List-10- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 721 } -- 1.3.6.1.4.1.9839.1.2.722.0 dout3-List-11- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 722 } -- 1.3.6.1.4.1.9839.1.2.723.0 dout3-List-12- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 723 } -- 1.3.6.1.4.1.9839.1.2.724.0 dout3-List-13- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 724 } -- 1.3.6.1.4.1.9839.1.2.725.0 dout3-List-14- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 725 } -- 1.3.6.1.4.1.9839.1.2.726.0 dout3-List-15- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Heater-Status-0-OFF-1-ON" ::= { snmpVariables 726 } -- 1.3.6.1.4.1.9839.1.2.727.0 dout4-List-0- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 727 } -- 1.3.6.1.4.1.9839.1.2.728.0 dout4-List-1- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 728 } -- 1.3.6.1.4.1.9839.1.2.729.0 dout4-List-2- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 729 } -- 1.3.6.1.4.1.9839.1.2.730.0 dout4-List-3- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 730 } -- 1.3.6.1.4.1.9839.1.2.731.0 dout4-List-4- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 731 } -- 1.3.6.1.4.1.9839.1.2.732.0 dout4-List-5- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 732 } -- 1.3.6.1.4.1.9839.1.2.733.0 dout4-List-6- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 733 } -- 1.3.6.1.4.1.9839.1.2.734.0 dout4-List-7- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 734 } -- 1.3.6.1.4.1.9839.1.2.735.0 dout4-List-8- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 735 } -- 1.3.6.1.4.1.9839.1.2.736.0 dout4-List-9- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 736 } -- 1.3.6.1.4.1.9839.1.2.737.0 dout4-List-10- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 737 } -- 1.3.6.1.4.1.9839.1.2.738.0 dout4-List-11- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 738 } -- 1.3.6.1.4.1.9839.1.2.739.0 dout4-List-12- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 739 } -- 1.3.6.1.4.1.9839.1.2.740.0 dout4-List-13- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 740 } -- 1.3.6.1.4.1.9839.1.2.741.0 dout4-List-14- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 741 } -- 1.3.6.1.4.1.9839.1.2.742.0 dout4-List-15- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 742 } -- 1.3.6.1.4.1.9839.1.2.743.0 dout5-List-0- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 743 } -- 1.3.6.1.4.1.9839.1.2.744.0 dout5-List-1- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 744 } -- 1.3.6.1.4.1.9839.1.2.745.0 dout5-List-2- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 745 } -- 1.3.6.1.4.1.9839.1.2.746.0 dout5-List-3- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 746 } -- 1.3.6.1.4.1.9839.1.2.747.0 dout5-List-4- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 747 } -- 1.3.6.1.4.1.9839.1.2.748.0 dout5-List-5- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 748 } -- 1.3.6.1.4.1.9839.1.2.749.0 dout5-List-6- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 749 } -- 1.3.6.1.4.1.9839.1.2.750.0 dout5-List-7- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 750 } -- 1.3.6.1.4.1.9839.1.2.751.0 dout5-List-8- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 751 } -- 1.3.6.1.4.1.9839.1.2.752.0 dout5-List-9- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 752 } -- 1.3.6.1.4.1.9839.1.2.753.0 dout5-List-10- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 753 } -- 1.3.6.1.4.1.9839.1.2.754.0 dout5-List-11- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 754 } -- 1.3.6.1.4.1.9839.1.2.755.0 dout5-List-12- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 755 } -- 1.3.6.1.4.1.9839.1.2.756.0 dout5-List-13- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 756 } -- 1.3.6.1.4.1.9839.1.2.757.0 dout5-List-14- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 757 } -- 1.3.6.1.4.1.9839.1.2.758.0 dout5-List-15- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Exhaust-Damper-Status-0-off-1-on-Only-applicable-for-units-equipped-with-exhaust-damper-" ::= { snmpVariables 758 } -- 1.3.6.1.4.1.9839.1.2.759.0 dout6-List-0- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-EEV-Status-0-off-1-on" ::= { snmpVariables 759 } -- 1.3.6.1.4.1.9839.1.2.760.0 dout6-List-1- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-EEV-Status-0-off-1-on" ::= { snmpVariables 760 } -- 1.3.6.1.4.1.9839.1.2.761.0 dout6-List-2- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-EEV-Status-0-off-1-on" ::= { snmpVariables 761 } -- 1.3.6.1.4.1.9839.1.2.762.0 dout6-List-3- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-EEV-Status-0-off-1-on" ::= { snmpVariables 762 } -- 1.3.6.1.4.1.9839.1.2.763.0 dout6-List-4- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-EEV-Status-0-off-1-on" ::= { snmpVariables 763 } -- 1.3.6.1.4.1.9839.1.2.764.0 dout6-List-5- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-EEV-Status-0-off-1-on" ::= { snmpVariables 764 } -- 1.3.6.1.4.1.9839.1.2.765.0 dout6-List-6- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-EEV-Status-0-off-1-on" ::= { snmpVariables 765 } -- 1.3.6.1.4.1.9839.1.2.766.0 dout6-List-7- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-EEV-Status-0-off-1-on" ::= { snmpVariables 766 } -- 1.3.6.1.4.1.9839.1.2.767.0 dout6-List-8- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-EEV-Status-0-off-1-on" ::= { snmpVariables 767 } -- 1.3.6.1.4.1.9839.1.2.768.0 dout6-List-9- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-EEV-Status-0-off-1-on" ::= { snmpVariables 768 } -- 1.3.6.1.4.1.9839.1.2.769.0 dout6-List-10- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-EEV-Status-0-off-1-on" ::= { snmpVariables 769 } -- 1.3.6.1.4.1.9839.1.2.770.0 dout6-List-11- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-EEV-Status-0-off-1-on" ::= { snmpVariables 770 } -- 1.3.6.1.4.1.9839.1.2.771.0 dout6-List-12- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-EEV-Status-0-off-1-on" ::= { snmpVariables 771 } -- 1.3.6.1.4.1.9839.1.2.772.0 dout6-List-13- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-EEV-Status-0-off-1-on" ::= { snmpVariables 772 } -- 1.3.6.1.4.1.9839.1.2.773.0 dout6-List-14- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-EEV-Status-0-off-1-on" ::= { snmpVariables 773 } -- 1.3.6.1.4.1.9839.1.2.774.0 dout6-List-15- OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-EEV-Status-0-off-1-on" ::= { snmpVariables 774 } -- 1.3.6.1.4.1.9839.1.2.775.0 hVAC-Status-List-0- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 775 } -- 1.3.6.1.4.1.9839.1.2.776.0 hVAC-Status-List-1- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 776 } -- 1.3.6.1.4.1.9839.1.2.777.0 hVAC-Status-List-2- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 777 } -- 1.3.6.1.4.1.9839.1.2.778.0 hVAC-Status-List-3- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 778 } -- 1.3.6.1.4.1.9839.1.2.779.0 hVAC-Status-List-4- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 779 } -- 1.3.6.1.4.1.9839.1.2.780.0 hVAC-Status-List-5- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 780 } -- 1.3.6.1.4.1.9839.1.2.781.0 hVAC-Status-List-6- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 781 } -- 1.3.6.1.4.1.9839.1.2.782.0 hVAC-Status-List-7- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 782 } -- 1.3.6.1.4.1.9839.1.2.783.0 hVAC-Status-List-8- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 783 } -- 1.3.6.1.4.1.9839.1.2.784.0 hVAC-Status-List-9- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 784 } -- 1.3.6.1.4.1.9839.1.2.785.0 hVAC-Status-List-10- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 785 } -- 1.3.6.1.4.1.9839.1.2.786.0 hVAC-Status-List-11- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 786 } -- 1.3.6.1.4.1.9839.1.2.787.0 hVAC-Status-List-12- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 787 } -- 1.3.6.1.4.1.9839.1.2.788.0 hVAC-Status-List-13- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 788 } -- 1.3.6.1.4.1.9839.1.2.789.0 hVAC-Status-List-14- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 789 } -- 1.3.6.1.4.1.9839.1.2.790.0 hVAC-Status-List-15- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Status-0-offline-1-on-2-off-by-alarm-3-off-by-BMS-4-off-by-scheduling-5-off-by-input-6-off-by-keyboard-7-manual-mode-8-turning-off" ::= { snmpVariables 790 } -- 1.3.6.1.4.1.9839.1.2.791.0 al-retain-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Too-Many-Internal-Memory-Writes-Controller-Alarm-Status" ::= { snmpVariables 791 } -- 1.3.6.1.4.1.9839.1.2.792.0 al-Err-retain-write-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Internal-Memory-Read-Write-Error-Controller-Alarm-Status" ::= { snmpVariables 792 } -- 1.3.6.1.4.1.9839.1.2.793.0 al-AmbTempPrb-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Outdoor-Temperature-Sensor-Error-Controller-Alarm-Status" ::= { snmpVariables 793 } -- 1.3.6.1.4.1.9839.1.2.794.0 al-RoomTempPrb-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 794 } -- 1.3.6.1.4.1.9839.1.2.795.0 al-RoomTempPrb1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Indoor-Temperature-Sensor1-Error-Controller-Alarm-Status" ::= { snmpVariables 795 } -- 1.3.6.1.4.1.9839.1.2.796.0 al-RoomTempPrb2-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Indoor-Temperature-Sensor2-Error-Controller-Alarm-Status" ::= { snmpVariables 796 } -- 1.3.6.1.4.1.9839.1.2.797.0 al-RoomTempPrb3-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Indoor-Temperature-Sensor3-Error-Controller-Alarm-Status" ::= { snmpVariables 797 } -- 1.3.6.1.4.1.9839.1.2.798.0 al-RoomTempPrb4-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Indoor-Temperature-Sensor4-Error-Controller-Alarm-Status" ::= { snmpVariables 798 } -- 1.3.6.1.4.1.9839.1.2.799.0 al-AmbHumPrb-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Humidity-Sensor-Alarm-Controller-Alarm-Status" ::= { snmpVariables 799 } -- 1.3.6.1.4.1.9839.1.2.800.0 al-Smoke-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Smoke-Fire-alarm-Controller-Alarm-Status" ::= { snmpVariables 800 } -- 1.3.6.1.4.1.9839.1.2.801.0 al-DG-Run-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Generator-Run-Controller-Alarm-Status" ::= { snmpVariables 801 } -- 1.3.6.1.4.1.9839.1.2.802.0 al-PwrFail-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "DC-Failover-Active-Controller-Alarm-Status" ::= { snmpVariables 802 } -- 1.3.6.1.4.1.9839.1.2.803.0 al-AC-Fail-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 803 } -- 1.3.6.1.4.1.9839.1.2.804.0 aL-LP-Lock-Comp-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 804 } -- 1.3.6.1.4.1.9839.1.2.805.0 al-HiRoomTemp-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "High-Temp-Alarm-Controller-Alarm-Status" ::= { snmpVariables 805 } -- 1.3.6.1.4.1.9839.1.2.806.0 al-Hydric-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Hydrogen-Alarm-Controller-Alarm-Status" ::= { snmpVariables 806 } -- 1.3.6.1.4.1.9839.1.2.807.0 al-LoRoomTemp-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Low-Temp-Alarm-Controller-Alarm-Status" ::= { snmpVariables 807 } -- 1.3.6.1.4.1.9839.1.2.808.0 al-Condenser-dirty-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 808 } -- 1.3.6.1.4.1.9839.1.2.809.0 al-OfflineSlave1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Offline-Alarm-Alarm-status" ::= { snmpVariables 809 } -- 1.3.6.1.4.1.9839.1.2.810.0 al-OfflineSlave2-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Offline-Alarm-Alarm-status" ::= { snmpVariables 810 } -- 1.3.6.1.4.1.9839.1.2.811.0 al-OfflineSlave3-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Offline-Alarm-Alarm-status" ::= { snmpVariables 811 } -- 1.3.6.1.4.1.9839.1.2.812.0 al-OfflineSlave4-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Offline-Alarm-Alarm-status" ::= { snmpVariables 812 } -- 1.3.6.1.4.1.9839.1.2.813.0 al-OfflineSlave5-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Offline-Alarm-Alarm-status" ::= { snmpVariables 813 } -- 1.3.6.1.4.1.9839.1.2.814.0 al-OfflineSlave6-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Offline-Alarm-Alarm-status" ::= { snmpVariables 814 } -- 1.3.6.1.4.1.9839.1.2.815.0 al-OfflineSlave7-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Offline-Alarm-Alarm-status" ::= { snmpVariables 815 } -- 1.3.6.1.4.1.9839.1.2.816.0 al-OfflineSlave8-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Offline-Alarm-Alarm-status" ::= { snmpVariables 816 } -- 1.3.6.1.4.1.9839.1.2.817.0 al-OfflineSlave9-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Offline-Alarm-Alarm-status" ::= { snmpVariables 817 } -- 1.3.6.1.4.1.9839.1.2.818.0 al-OfflineSlave10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Offline-Alarm-Alarm-status" ::= { snmpVariables 818 } -- 1.3.6.1.4.1.9839.1.2.819.0 al-OfflineSlave11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Offline-Alarm-Alarm-status" ::= { snmpVariables 819 } -- 1.3.6.1.4.1.9839.1.2.820.0 al-OfflineSlave12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Offline-Alarm-Alarm-status" ::= { snmpVariables 820 } -- 1.3.6.1.4.1.9839.1.2.821.0 al-OfflineSlave13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Offline-Alarm-Alarm-status" ::= { snmpVariables 821 } -- 1.3.6.1.4.1.9839.1.2.822.0 al-OfflineSlave14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Offline-Alarm-Alarm-status" ::= { snmpVariables 822 } -- 1.3.6.1.4.1.9839.1.2.823.0 al-OfflineSlave15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Offline-Alarm-Alarm-status" ::= { snmpVariables 823 } -- 1.3.6.1.4.1.9839.1.2.824.0 al-OfflineSlave16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Offline-Alarm-Alarm-status" ::= { snmpVariables 824 } -- 1.3.6.1.4.1.9839.1.2.825.0 al-GenAlrmSlave1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 825 } -- 1.3.6.1.4.1.9839.1.2.826.0 al-GenAlrmSlave2-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 826 } -- 1.3.6.1.4.1.9839.1.2.827.0 al-GenAlrmSlave3-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 827 } -- 1.3.6.1.4.1.9839.1.2.828.0 al-GenAlrmSlave4-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 828 } -- 1.3.6.1.4.1.9839.1.2.829.0 al-GenAlrmSlave5-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 829 } -- 1.3.6.1.4.1.9839.1.2.830.0 al-GenAlrmSlave6-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 830 } -- 1.3.6.1.4.1.9839.1.2.831.0 al-GenAlrmSlave7-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 831 } -- 1.3.6.1.4.1.9839.1.2.832.0 al-GenAlrmSlave8-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 832 } -- 1.3.6.1.4.1.9839.1.2.833.0 al-GenAlrmSlave9-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 833 } -- 1.3.6.1.4.1.9839.1.2.834.0 al-GenAlrmSlave10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 834 } -- 1.3.6.1.4.1.9839.1.2.835.0 al-GenAlrmSlave11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 835 } -- 1.3.6.1.4.1.9839.1.2.836.0 al-GenAlrmSlave12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 836 } -- 1.3.6.1.4.1.9839.1.2.837.0 al-GenAlrmSlave13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 837 } -- 1.3.6.1.4.1.9839.1.2.838.0 al-GenAlrmSlave14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 838 } -- 1.3.6.1.4.1.9839.1.2.839.0 al-GenAlrmSlave15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 839 } -- 1.3.6.1.4.1.9839.1.2.840.0 al-GenAlrmSlave16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 840 } -- 1.3.6.1.4.1.9839.1.2.841.0 al-CompHiP-Prb-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 841 } -- 1.3.6.1.4.1.9839.1.2.842.0 al-DscgTempPrb-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 842 } -- 1.3.6.1.4.1.9839.1.2.843.0 al-SuctP-Prb-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 843 } -- 1.3.6.1.4.1.9839.1.2.844.0 al-SuctTemp-Prb-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 844 } -- 1.3.6.1.4.1.9839.1.2.845.0 al-SupplyTempPrb-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 845 } -- 1.3.6.1.4.1.9839.1.2.846.0 al-CondenTempPrb-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 846 } -- 1.3.6.1.4.1.9839.1.2.847.0 al-OvldComp-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 847 } -- 1.3.6.1.4.1.9839.1.2.848.0 al-HiP-Sw-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 848 } -- 1.3.6.1.4.1.9839.1.2.849.0 al-OvldSupplyFan-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 849 } -- 1.3.6.1.4.1.9839.1.2.850.0 al-HiP-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 850 } -- 1.3.6.1.4.1.9839.1.2.851.0 al-LowP-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 851 } -- 1.3.6.1.4.1.9839.1.2.852.0 al-LowP-Lim-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 852 } -- 1.3.6.1.4.1.9839.1.2.853.0 al-Filt-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 853 } -- 1.3.6.1.4.1.9839.1.2.854.0 al-Dust-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 854 } -- 1.3.6.1.4.1.9839.1.2.855.0 al-MechanicalCoolDefect-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 855 } -- 1.3.6.1.4.1.9839.1.2.856.0 al-Damper-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 856 } -- 1.3.6.1.4.1.9839.1.2.857.0 al-LowSupplyTemp-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 857 } -- 1.3.6.1.4.1.9839.1.2.858.0 al-ExpansionOffline-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 858 } -- 1.3.6.1.4.1.9839.1.2.859.0 al-MasterOffline-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 859 } -- 1.3.6.1.4.1.9839.1.2.860.0 al-StartFailRetry-BLDC1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 860 } -- 1.3.6.1.4.1.9839.1.2.861.0 al-StartFailLock-BLDC1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 861 } -- 1.3.6.1.4.1.9839.1.2.862.0 al-LowDeltaP-BLDC1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 862 } -- 1.3.6.1.4.1.9839.1.2.863.0 al-HighDscgT-BLDC1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 863 } -- 1.3.6.1.4.1.9839.1.2.864.0 alEnv02-HighRatio-BLDC-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 864 } -- 1.3.6.1.4.1.9839.1.2.865.0 alEnv03-HighDscg-BLDC-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 865 } -- 1.3.6.1.4.1.9839.1.2.866.0 alEnv04-HighCurr-BLDC-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 866 } -- 1.3.6.1.4.1.9839.1.2.867.0 alEnv05-HighSuct-BLDC-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 867 } -- 1.3.6.1.4.1.9839.1.2.868.0 alEnv06-LowRatio-BLDC-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 868 } -- 1.3.6.1.4.1.9839.1.2.869.0 aLEnv07-LowDP-BLDC-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 869 } -- 1.3.6.1.4.1.9839.1.2.870.0 alEnv08-LowDscg-BLDC-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 870 } -- 1.3.6.1.4.1.9839.1.2.871.0 alEnv09-LowSuct-BLDC-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 871 } -- 1.3.6.1.4.1.9839.1.2.872.0 alEnv10-HDT-BLDC-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 872 } -- 1.3.6.1.4.1.9839.1.2.873.0 al01-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 873 } -- 1.3.6.1.4.1.9839.1.2.874.0 al02-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 874 } -- 1.3.6.1.4.1.9839.1.2.875.0 al03-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 875 } -- 1.3.6.1.4.1.9839.1.2.876.0 al04-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 876 } -- 1.3.6.1.4.1.9839.1.2.877.0 al05-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 877 } -- 1.3.6.1.4.1.9839.1.2.878.0 al06-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 878 } -- 1.3.6.1.4.1.9839.1.2.879.0 al07-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 879 } -- 1.3.6.1.4.1.9839.1.2.880.0 al08-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 880 } -- 1.3.6.1.4.1.9839.1.2.881.0 al09-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 881 } -- 1.3.6.1.4.1.9839.1.2.882.0 al10-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 882 } -- 1.3.6.1.4.1.9839.1.2.883.0 al11-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 883 } -- 1.3.6.1.4.1.9839.1.2.884.0 al12-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 884 } -- 1.3.6.1.4.1.9839.1.2.885.0 al13-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 885 } -- 1.3.6.1.4.1.9839.1.2.886.0 al14-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 886 } -- 1.3.6.1.4.1.9839.1.2.887.0 al15-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 887 } -- 1.3.6.1.4.1.9839.1.2.888.0 al16-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 888 } -- 1.3.6.1.4.1.9839.1.2.889.0 al17-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 889 } -- 1.3.6.1.4.1.9839.1.2.890.0 al18-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 890 } -- 1.3.6.1.4.1.9839.1.2.891.0 al19-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 891 } -- 1.3.6.1.4.1.9839.1.2.892.0 al20-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 892 } -- 1.3.6.1.4.1.9839.1.2.893.0 al21-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 893 } -- 1.3.6.1.4.1.9839.1.2.894.0 al22-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 894 } -- 1.3.6.1.4.1.9839.1.2.895.0 al23-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 895 } -- 1.3.6.1.4.1.9839.1.2.896.0 al24-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 896 } -- 1.3.6.1.4.1.9839.1.2.897.0 al25-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 897 } -- 1.3.6.1.4.1.9839.1.2.898.0 al26-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 898 } -- 1.3.6.1.4.1.9839.1.2.899.0 al27-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 899 } -- 1.3.6.1.4.1.9839.1.2.900.0 al28-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 900 } -- 1.3.6.1.4.1.9839.1.2.901.0 al29-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 901 } -- 1.3.6.1.4.1.9839.1.2.902.0 al98-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 902 } -- 1.3.6.1.4.1.9839.1.2.903.0 al99-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 903 } -- 1.3.6.1.4.1.9839.1.2.904.0 alSafe101-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 904 } -- 1.3.6.1.4.1.9839.1.2.905.0 alSafe102-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 905 } -- 1.3.6.1.4.1.9839.1.2.906.0 alSafe103-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 906 } -- 1.3.6.1.4.1.9839.1.2.907.0 alSafe104-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 907 } -- 1.3.6.1.4.1.9839.1.2.908.0 alSafe105-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 908 } -- 1.3.6.1.4.1.9839.1.2.909.0 alSafe106-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 909 } -- 1.3.6.1.4.1.9839.1.2.910.0 alSafe107-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 910 } -- 1.3.6.1.4.1.9839.1.2.911.0 alSafe108-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 911 } -- 1.3.6.1.4.1.9839.1.2.912.0 alSafe109-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 912 } -- 1.3.6.1.4.1.9839.1.2.913.0 alSafe110-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 913 } -- 1.3.6.1.4.1.9839.1.2.914.0 alSafe111-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 914 } -- 1.3.6.1.4.1.9839.1.2.915.0 alSafe112-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 915 } -- 1.3.6.1.4.1.9839.1.2.916.0 alSafe113-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 916 } -- 1.3.6.1.4.1.9839.1.2.917.0 alSafe114-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 917 } -- 1.3.6.1.4.1.9839.1.2.918.0 alSafe115-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 918 } -- 1.3.6.1.4.1.9839.1.2.919.0 alSafe116-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 919 } -- 1.3.6.1.4.1.9839.1.2.920.0 alSafe201-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 920 } -- 1.3.6.1.4.1.9839.1.2.921.0 alSafe202-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 921 } -- 1.3.6.1.4.1.9839.1.2.922.0 alSafe203-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 922 } -- 1.3.6.1.4.1.9839.1.2.923.0 alSafe204-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 923 } -- 1.3.6.1.4.1.9839.1.2.924.0 alSafe205-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 924 } -- 1.3.6.1.4.1.9839.1.2.925.0 alSafe206-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 925 } -- 1.3.6.1.4.1.9839.1.2.926.0 alSafe207-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 926 } -- 1.3.6.1.4.1.9839.1.2.927.0 alSafe208-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 927 } -- 1.3.6.1.4.1.9839.1.2.928.0 alSafe209-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 928 } -- 1.3.6.1.4.1.9839.1.2.929.0 alSafe210-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 929 } -- 1.3.6.1.4.1.9839.1.2.930.0 alSafe211-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 930 } -- 1.3.6.1.4.1.9839.1.2.931.0 alSafe212-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 931 } -- 1.3.6.1.4.1.9839.1.2.932.0 alSafe213-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 932 } -- 1.3.6.1.4.1.9839.1.2.933.0 alSafe214-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 933 } -- 1.3.6.1.4.1.9839.1.2.934.0 alSafe215-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 934 } -- 1.3.6.1.4.1.9839.1.2.935.0 alSafe216-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 935 } -- 1.3.6.1.4.1.9839.1.2.936.0 al-InvOffline-PWRP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 936 } -- 1.3.6.1.4.1.9839.1.2.937.0 al-LowSH-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 937 } -- 1.3.6.1.4.1.9839.1.2.938.0 al-LOP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 938 } -- 1.3.6.1.4.1.9839.1.2.939.0 al-MOP-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 939 } -- 1.3.6.1.4.1.9839.1.2.940.0 al-LowSuct-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 940 } -- 1.3.6.1.4.1.9839.1.2.941.0 al-EEV-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 941 } -- 1.3.6.1.4.1.9839.1.2.942.0 al-EmergClos-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 942 } -- 1.3.6.1.4.1.9839.1.2.943.0 al-OutEnv-BLDC1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 943 } -- 1.3.6.1.4.1.9839.1.2.944.0 al-ComprOff-BLDC1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 944 } -- 1.3.6.1.4.1.9839.1.2.945.0 aL-DisStartDpState-BLDC1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 945 } -- 1.3.6.1.4.1.9839.1.2.946.0 al-HiTempCond-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 946 } -- 1.3.6.1.4.1.9839.1.2.947.0 al-SelfTuning-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 947 } -- 1.3.6.1.4.1.9839.1.2.948.0 al-TempDelta-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 948 } -- 1.3.6.1.4.1.9839.1.2.949.0 al-P-Delta-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 949 } -- 1.3.6.1.4.1.9839.1.2.950.0 al-RangeError-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 950 } -- 1.3.6.1.4.1.9839.1.2.951.0 al-ServicePosit-perc-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 951 } -- 1.3.6.1.4.1.9839.1.2.952.0 al-ValveID-1-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 952 } -- 1.3.6.1.4.1.9839.1.2.953.0 al-FilterAirPressPrb-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved" ::= { snmpVariables 953 } -- 1.3.6.1.4.1.9839.1.2.954.0 al-retain-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 954 } -- 1.3.6.1.4.1.9839.1.2.955.0 al-Err-retain-write-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 955 } -- 1.3.6.1.4.1.9839.1.2.956.0 al-SupplyTempPrb-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 956 } -- 1.3.6.1.4.1.9839.1.2.957.0 al-RoomTempPrb-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 957 } -- 1.3.6.1.4.1.9839.1.2.958.0 al-AmbTempPrb-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 958 } -- 1.3.6.1.4.1.9839.1.2.959.0 al-CompHiP-Prb-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 959 } -- 1.3.6.1.4.1.9839.1.2.960.0 al-DscgTempPrb-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 960 } -- 1.3.6.1.4.1.9839.1.2.961.0 al-SuctP-Prb-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 961 } -- 1.3.6.1.4.1.9839.1.2.962.0 al-SuctTemp-Prb-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 962 } -- 1.3.6.1.4.1.9839.1.2.963.0 al-CondenTempPrb-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 963 } -- 1.3.6.1.4.1.9839.1.2.964.0 al-AmbHumPrb-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Humidity-Alarm-Alarm-status" ::= { snmpVariables 964 } -- 1.3.6.1.4.1.9839.1.2.965.0 al-Smoke-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 965 } -- 1.3.6.1.4.1.9839.1.2.966.0 al-OvldComp-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Inverter-Overload-Alarm-status" ::= { snmpVariables 966 } -- 1.3.6.1.4.1.9839.1.2.967.0 al-HiP-Sw-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 967 } -- 1.3.6.1.4.1.9839.1.2.968.0 al-HiP-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 968 } -- 1.3.6.1.4.1.9839.1.2.969.0 al-PwrFail-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-DC-Failover-Active-Alarm-status" ::= { snmpVariables 969 } -- 1.3.6.1.4.1.9839.1.2.970.0 al-OvldSupplyFan-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 970 } -- 1.3.6.1.4.1.9839.1.2.971.0 aL-LP-Lock-Comp-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 971 } -- 1.3.6.1.4.1.9839.1.2.972.0 al-LowP-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 972 } -- 1.3.6.1.4.1.9839.1.2.973.0 al-LowP-Lim-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 973 } -- 1.3.6.1.4.1.9839.1.2.974.0 al-Filt-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 974 } -- 1.3.6.1.4.1.9839.1.2.975.0 al-Dust-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-AFPD-Triggered-Alarm-status" ::= { snmpVariables 975 } -- 1.3.6.1.4.1.9839.1.2.976.0 al-MechanicalCoolDefect-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 976 } -- 1.3.6.1.4.1.9839.1.2.977.0 al-Damper-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Damper-Alarm-Alarm-status" ::= { snmpVariables 977 } -- 1.3.6.1.4.1.9839.1.2.978.0 al-LowSupplyTemp-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 978 } -- 1.3.6.1.4.1.9839.1.2.979.0 al-HiRoomTemp-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 979 } -- 1.3.6.1.4.1.9839.1.2.980.0 al-LoRoomTemp-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 980 } -- 1.3.6.1.4.1.9839.1.2.981.0 al-LowSH-1-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 981 } -- 1.3.6.1.4.1.9839.1.2.982.0 al-LOP-1-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 982 } -- 1.3.6.1.4.1.9839.1.2.983.0 al-MOP-1-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 983 } -- 1.3.6.1.4.1.9839.1.2.984.0 al-LowSuct-1-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 984 } -- 1.3.6.1.4.1.9839.1.2.985.0 al-EEV-1-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-EEV-Alarm-Alarm-status" ::= { snmpVariables 985 } -- 1.3.6.1.4.1.9839.1.2.986.0 al-EmergClos-1-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 986 } -- 1.3.6.1.4.1.9839.1.2.987.0 al-ExpansionOffline-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 987 } -- 1.3.6.1.4.1.9839.1.2.988.0 al-InvOffline-PWRP-1-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Inverter-Offline-Alarm-status" ::= { snmpVariables 988 } -- 1.3.6.1.4.1.9839.1.2.989.0 al-FilterAirPressPrb-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 989 } -- 1.3.6.1.4.1.9839.1.2.990.0 al-PWRP-1-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-BLDC-Alarm-Alarm-status" ::= { snmpVariables 990 } -- 1.3.6.1.4.1.9839.1.2.991.0 al-Condenser-dirty-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Dirty-Condenser-Alarm-status" ::= { snmpVariables 991 } -- 1.3.6.1.4.1.9839.1.2.992.0 al-HighDscgT-BLDC1-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 992 } -- 1.3.6.1.4.1.9839.1.2.993.0 al-retain-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 993 } -- 1.3.6.1.4.1.9839.1.2.994.0 al-Err-retain-write-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 994 } -- 1.3.6.1.4.1.9839.1.2.995.0 al-SupplyTempPrb-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 995 } -- 1.3.6.1.4.1.9839.1.2.996.0 al-RoomTempPrb-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 996 } -- 1.3.6.1.4.1.9839.1.2.997.0 al-AmbTempPrb-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 997 } -- 1.3.6.1.4.1.9839.1.2.998.0 al-CompHiP-Prb-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 998 } -- 1.3.6.1.4.1.9839.1.2.999.0 al-DscgTempPrb-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 999 } -- 1.3.6.1.4.1.9839.1.2.1000.0 al-SuctP-Prb-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1000 } -- 1.3.6.1.4.1.9839.1.2.1001.0 al-SuctTemp-Prb-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1001 } -- 1.3.6.1.4.1.9839.1.2.1002.0 al-CondenTempPrb-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1002 } -- 1.3.6.1.4.1.9839.1.2.1003.0 al-AmbHumPrb-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1003 } -- 1.3.6.1.4.1.9839.1.2.1004.0 al-Smoke-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1004 } -- 1.3.6.1.4.1.9839.1.2.1005.0 al-OvldComp-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Inverter-Overload-Alarm-status" ::= { snmpVariables 1005 } -- 1.3.6.1.4.1.9839.1.2.1006.0 al-HiP-Sw-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1006 } -- 1.3.6.1.4.1.9839.1.2.1007.0 al-HiP-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1007 } -- 1.3.6.1.4.1.9839.1.2.1008.0 al-PwrFail-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1008 } -- 1.3.6.1.4.1.9839.1.2.1009.0 al-OvldSupplyFan-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1009 } -- 1.3.6.1.4.1.9839.1.2.1010.0 aL-LP-Lock-Comp-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1010 } -- 1.3.6.1.4.1.9839.1.2.1011.0 al-LowP-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1011 } -- 1.3.6.1.4.1.9839.1.2.1012.0 al-LowP-Lim-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1012 } -- 1.3.6.1.4.1.9839.1.2.1013.0 al-Filt-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1013 } -- 1.3.6.1.4.1.9839.1.2.1014.0 al-Dust-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1014 } -- 1.3.6.1.4.1.9839.1.2.1015.0 al-MechanicalCoolDefect-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1015 } -- 1.3.6.1.4.1.9839.1.2.1016.0 al-Damper-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Damper-Alarm-Alarm-status" ::= { snmpVariables 1016 } -- 1.3.6.1.4.1.9839.1.2.1017.0 al-LowSupplyTemp-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1017 } -- 1.3.6.1.4.1.9839.1.2.1018.0 al-HiRoomTemp-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1018 } -- 1.3.6.1.4.1.9839.1.2.1019.0 al-LoRoomTemp-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1019 } -- 1.3.6.1.4.1.9839.1.2.1020.0 al-LowSH-1-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1020 } -- 1.3.6.1.4.1.9839.1.2.1021.0 al-LOP-1-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1021 } -- 1.3.6.1.4.1.9839.1.2.1022.0 al-MOP-1-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1022 } -- 1.3.6.1.4.1.9839.1.2.1023.0 al-LowSuct-1-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1023 } -- 1.3.6.1.4.1.9839.1.2.1024.0 al-EEV-1-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-EEV-Alarm-Alarm-status" ::= { snmpVariables 1024 } -- 1.3.6.1.4.1.9839.1.2.1025.0 al-EmergClos-1-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1025 } -- 1.3.6.1.4.1.9839.1.2.1026.0 al-ExpansionOffline-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1026 } -- 1.3.6.1.4.1.9839.1.2.1027.0 al-InvOffline-PWRP-1-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Inverter-Offline-Alarm-status" ::= { snmpVariables 1027 } -- 1.3.6.1.4.1.9839.1.2.1028.0 al-FilterAirPressPrb-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1028 } -- 1.3.6.1.4.1.9839.1.2.1029.0 al-PWRP-1-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1029 } -- 1.3.6.1.4.1.9839.1.2.1030.0 al-Condenser-dirty-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1030 } -- 1.3.6.1.4.1.9839.1.2.1031.0 al-HighDscgT-BLDC1-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1031 } -- 1.3.6.1.4.1.9839.1.2.1032.0 al-retain-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 1032 } -- 1.3.6.1.4.1.9839.1.2.1033.0 al-Err-retain-write-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 1033 } -- 1.3.6.1.4.1.9839.1.2.1034.0 al-SupplyTempPrb-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1034 } -- 1.3.6.1.4.1.9839.1.2.1035.0 al-RoomTempPrb-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1035 } -- 1.3.6.1.4.1.9839.1.2.1036.0 al-AmbTempPrb-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1036 } -- 1.3.6.1.4.1.9839.1.2.1037.0 al-CompHiP-Prb-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1037 } -- 1.3.6.1.4.1.9839.1.2.1038.0 al-DscgTempPrb-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1038 } -- 1.3.6.1.4.1.9839.1.2.1039.0 al-SuctP-Prb-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1039 } -- 1.3.6.1.4.1.9839.1.2.1040.0 al-SuctTemp-Prb-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1040 } -- 1.3.6.1.4.1.9839.1.2.1041.0 al-CondenTempPrb-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1041 } -- 1.3.6.1.4.1.9839.1.2.1042.0 al-AmbHumPrb-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1042 } -- 1.3.6.1.4.1.9839.1.2.1043.0 al-Smoke-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1043 } -- 1.3.6.1.4.1.9839.1.2.1044.0 al-OvldComp-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Inverter-Overload-Alarm-status" ::= { snmpVariables 1044 } -- 1.3.6.1.4.1.9839.1.2.1045.0 al-HiP-Sw-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1045 } -- 1.3.6.1.4.1.9839.1.2.1046.0 al-HiP-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1046 } -- 1.3.6.1.4.1.9839.1.2.1047.0 al-PwrFail-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1047 } -- 1.3.6.1.4.1.9839.1.2.1048.0 al-OvldSupplyFan-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1048 } -- 1.3.6.1.4.1.9839.1.2.1049.0 aL-LP-Lock-Comp-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1049 } -- 1.3.6.1.4.1.9839.1.2.1050.0 al-LowP-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1050 } -- 1.3.6.1.4.1.9839.1.2.1051.0 al-LowP-Lim-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1051 } -- 1.3.6.1.4.1.9839.1.2.1052.0 al-Filt-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1052 } -- 1.3.6.1.4.1.9839.1.2.1053.0 al-Dust-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1053 } -- 1.3.6.1.4.1.9839.1.2.1054.0 al-MechanicalCoolDefect-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1054 } -- 1.3.6.1.4.1.9839.1.2.1055.0 al-Damper-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Damper-Alarm-Alarm-status" ::= { snmpVariables 1055 } -- 1.3.6.1.4.1.9839.1.2.1056.0 al-LowSupplyTemp-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1056 } -- 1.3.6.1.4.1.9839.1.2.1057.0 al-HiRoomTemp-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1057 } -- 1.3.6.1.4.1.9839.1.2.1058.0 al-LoRoomTemp-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1058 } -- 1.3.6.1.4.1.9839.1.2.1059.0 al-LowSH-1-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1059 } -- 1.3.6.1.4.1.9839.1.2.1060.0 al-LOP-1-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1060 } -- 1.3.6.1.4.1.9839.1.2.1061.0 al-MOP-1-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1061 } -- 1.3.6.1.4.1.9839.1.2.1062.0 al-LowSuct-1-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1062 } -- 1.3.6.1.4.1.9839.1.2.1063.0 al-EEV-1-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-EEV-Alarm-Alarm-status" ::= { snmpVariables 1063 } -- 1.3.6.1.4.1.9839.1.2.1064.0 al-EmergClos-1-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1064 } -- 1.3.6.1.4.1.9839.1.2.1065.0 al-ExpansionOffline-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1065 } -- 1.3.6.1.4.1.9839.1.2.1066.0 al-InvOffline-PWRP-1-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Inverter-Offline-Alarm-status" ::= { snmpVariables 1066 } -- 1.3.6.1.4.1.9839.1.2.1067.0 al-FilterAirPressPrb-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1067 } -- 1.3.6.1.4.1.9839.1.2.1068.0 al-PWRP-1-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1068 } -- 1.3.6.1.4.1.9839.1.2.1069.0 al-Condenser-dirty-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1069 } -- 1.3.6.1.4.1.9839.1.2.1070.0 al-HighDscgT-BLDC1-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1070 } -- 1.3.6.1.4.1.9839.1.2.1071.0 al-retain-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 1071 } -- 1.3.6.1.4.1.9839.1.2.1072.0 al-Err-retain-write-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 1072 } -- 1.3.6.1.4.1.9839.1.2.1073.0 al-SupplyTempPrb-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1073 } -- 1.3.6.1.4.1.9839.1.2.1074.0 al-RoomTempPrb-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1074 } -- 1.3.6.1.4.1.9839.1.2.1075.0 al-AmbTempPrb-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1075 } -- 1.3.6.1.4.1.9839.1.2.1076.0 al-CompHiP-Prb-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1076 } -- 1.3.6.1.4.1.9839.1.2.1077.0 al-DscgTempPrb-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1077 } -- 1.3.6.1.4.1.9839.1.2.1078.0 al-SuctP-Prb-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1078 } -- 1.3.6.1.4.1.9839.1.2.1079.0 al-SuctTemp-Prb-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1079 } -- 1.3.6.1.4.1.9839.1.2.1080.0 al-CondenTempPrb-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1080 } -- 1.3.6.1.4.1.9839.1.2.1081.0 al-AmbHumPrb-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1081 } -- 1.3.6.1.4.1.9839.1.2.1082.0 al-Smoke-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1082 } -- 1.3.6.1.4.1.9839.1.2.1083.0 al-OvldComp-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Inverter-Overload-Alarm-status" ::= { snmpVariables 1083 } -- 1.3.6.1.4.1.9839.1.2.1084.0 al-HiP-Sw-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1084 } -- 1.3.6.1.4.1.9839.1.2.1085.0 al-HiP-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1085 } -- 1.3.6.1.4.1.9839.1.2.1086.0 al-PwrFail-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1086 } -- 1.3.6.1.4.1.9839.1.2.1087.0 al-OvldSupplyFan-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1087 } -- 1.3.6.1.4.1.9839.1.2.1088.0 aL-LP-Lock-Comp-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1088 } -- 1.3.6.1.4.1.9839.1.2.1089.0 al-LowP-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1089 } -- 1.3.6.1.4.1.9839.1.2.1090.0 al-LowP-Lim-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1090 } -- 1.3.6.1.4.1.9839.1.2.1091.0 al-Filt-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1091 } -- 1.3.6.1.4.1.9839.1.2.1092.0 al-Dust-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1092 } -- 1.3.6.1.4.1.9839.1.2.1093.0 al-MechanicalCoolDefect-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1093 } -- 1.3.6.1.4.1.9839.1.2.1094.0 al-Damper-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Damper-Alarm-Alarm-status" ::= { snmpVariables 1094 } -- 1.3.6.1.4.1.9839.1.2.1095.0 al-LowSupplyTemp-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1095 } -- 1.3.6.1.4.1.9839.1.2.1096.0 al-HiRoomTemp-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1096 } -- 1.3.6.1.4.1.9839.1.2.1097.0 al-LoRoomTemp-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1097 } -- 1.3.6.1.4.1.9839.1.2.1098.0 al-LowSH-1-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1098 } -- 1.3.6.1.4.1.9839.1.2.1099.0 al-LOP-1-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1099 } -- 1.3.6.1.4.1.9839.1.2.1100.0 al-MOP-1-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1100 } -- 1.3.6.1.4.1.9839.1.2.1101.0 al-LowSuct-1-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1101 } -- 1.3.6.1.4.1.9839.1.2.1102.0 al-EEV-1-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-EEV-Alarm-Alarm-status" ::= { snmpVariables 1102 } -- 1.3.6.1.4.1.9839.1.2.1103.0 al-EmergClos-1-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1103 } -- 1.3.6.1.4.1.9839.1.2.1104.0 al-ExpansionOffline-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1104 } -- 1.3.6.1.4.1.9839.1.2.1105.0 al-InvOffline-PWRP-1-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Inverter-Offline-Alarm-status" ::= { snmpVariables 1105 } -- 1.3.6.1.4.1.9839.1.2.1106.0 al-FilterAirPressPrb-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1106 } -- 1.3.6.1.4.1.9839.1.2.1107.0 al-PWRP-1-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1107 } -- 1.3.6.1.4.1.9839.1.2.1108.0 al-Condenser-dirty-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1108 } -- 1.3.6.1.4.1.9839.1.2.1109.0 al-HighDscgT-BLDC1-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1109 } -- 1.3.6.1.4.1.9839.1.2.1110.0 al-retain-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 1110 } -- 1.3.6.1.4.1.9839.1.2.1111.0 al-Err-retain-write-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 1111 } -- 1.3.6.1.4.1.9839.1.2.1112.0 al-SupplyTempPrb-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1112 } -- 1.3.6.1.4.1.9839.1.2.1113.0 al-RoomTempPrb-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1113 } -- 1.3.6.1.4.1.9839.1.2.1114.0 al-AmbTempPrb-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1114 } -- 1.3.6.1.4.1.9839.1.2.1115.0 al-CompHiP-Prb-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1115 } -- 1.3.6.1.4.1.9839.1.2.1116.0 al-DscgTempPrb-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1116 } -- 1.3.6.1.4.1.9839.1.2.1117.0 al-SuctP-Prb-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1117 } -- 1.3.6.1.4.1.9839.1.2.1118.0 al-SuctTemp-Prb-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1118 } -- 1.3.6.1.4.1.9839.1.2.1119.0 al-CondenTempPrb-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1119 } -- 1.3.6.1.4.1.9839.1.2.1120.0 al-AmbHumPrb-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1120 } -- 1.3.6.1.4.1.9839.1.2.1121.0 al-Smoke-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1121 } -- 1.3.6.1.4.1.9839.1.2.1122.0 al-OvldComp-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Inverter-Overload-Alarm-status" ::= { snmpVariables 1122 } -- 1.3.6.1.4.1.9839.1.2.1123.0 al-HiP-Sw-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1123 } -- 1.3.6.1.4.1.9839.1.2.1124.0 al-HiP-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1124 } -- 1.3.6.1.4.1.9839.1.2.1125.0 al-PwrFail-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1125 } -- 1.3.6.1.4.1.9839.1.2.1126.0 al-OvldSupplyFan-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1126 } -- 1.3.6.1.4.1.9839.1.2.1127.0 aL-LP-Lock-Comp-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1127 } -- 1.3.6.1.4.1.9839.1.2.1128.0 al-LowP-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1128 } -- 1.3.6.1.4.1.9839.1.2.1129.0 al-LowP-Lim-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1129 } -- 1.3.6.1.4.1.9839.1.2.1130.0 al-Filt-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1130 } -- 1.3.6.1.4.1.9839.1.2.1131.0 al-Dust-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1131 } -- 1.3.6.1.4.1.9839.1.2.1132.0 al-MechanicalCoolDefect-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1132 } -- 1.3.6.1.4.1.9839.1.2.1133.0 al-Damper-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Damper-Alarm-Alarm-status" ::= { snmpVariables 1133 } -- 1.3.6.1.4.1.9839.1.2.1134.0 al-LowSupplyTemp-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1134 } -- 1.3.6.1.4.1.9839.1.2.1135.0 al-HiRoomTemp-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1135 } -- 1.3.6.1.4.1.9839.1.2.1136.0 al-LoRoomTemp-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1136 } -- 1.3.6.1.4.1.9839.1.2.1137.0 al-LowSH-1-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1137 } -- 1.3.6.1.4.1.9839.1.2.1138.0 al-LOP-1-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1138 } -- 1.3.6.1.4.1.9839.1.2.1139.0 al-MOP-1-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1139 } -- 1.3.6.1.4.1.9839.1.2.1140.0 al-LowSuct-1-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1140 } -- 1.3.6.1.4.1.9839.1.2.1141.0 al-EEV-1-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-EEV-Alarm-Alarm-status" ::= { snmpVariables 1141 } -- 1.3.6.1.4.1.9839.1.2.1142.0 al-EmergClos-1-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1142 } -- 1.3.6.1.4.1.9839.1.2.1143.0 al-ExpansionOffline-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1143 } -- 1.3.6.1.4.1.9839.1.2.1144.0 al-InvOffline-PWRP-1-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Inverter-Offline-Alarm-status" ::= { snmpVariables 1144 } -- 1.3.6.1.4.1.9839.1.2.1145.0 al-FilterAirPressPrb-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1145 } -- 1.3.6.1.4.1.9839.1.2.1146.0 al-PWRP-1-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1146 } -- 1.3.6.1.4.1.9839.1.2.1147.0 al-Condenser-dirty-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1147 } -- 1.3.6.1.4.1.9839.1.2.1148.0 al-HighDscgT-BLDC1-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1148 } -- 1.3.6.1.4.1.9839.1.2.1149.0 al-retain-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 1149 } -- 1.3.6.1.4.1.9839.1.2.1150.0 al-Err-retain-write-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 1150 } -- 1.3.6.1.4.1.9839.1.2.1151.0 al-SupplyTempPrb-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1151 } -- 1.3.6.1.4.1.9839.1.2.1152.0 al-RoomTempPrb-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1152 } -- 1.3.6.1.4.1.9839.1.2.1153.0 al-AmbTempPrb-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1153 } -- 1.3.6.1.4.1.9839.1.2.1154.0 al-CompHiP-Prb-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1154 } -- 1.3.6.1.4.1.9839.1.2.1155.0 al-DscgTempPrb-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1155 } -- 1.3.6.1.4.1.9839.1.2.1156.0 al-SuctP-Prb-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1156 } -- 1.3.6.1.4.1.9839.1.2.1157.0 al-SuctTemp-Prb-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1157 } -- 1.3.6.1.4.1.9839.1.2.1158.0 al-CondenTempPrb-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1158 } -- 1.3.6.1.4.1.9839.1.2.1159.0 al-AmbHumPrb-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1159 } -- 1.3.6.1.4.1.9839.1.2.1160.0 al-Smoke-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1160 } -- 1.3.6.1.4.1.9839.1.2.1161.0 al-OvldComp-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Inverter-Overload-Alarm-status" ::= { snmpVariables 1161 } -- 1.3.6.1.4.1.9839.1.2.1162.0 al-HiP-Sw-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1162 } -- 1.3.6.1.4.1.9839.1.2.1163.0 al-HiP-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1163 } -- 1.3.6.1.4.1.9839.1.2.1164.0 al-PwrFail-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1164 } -- 1.3.6.1.4.1.9839.1.2.1165.0 al-OvldSupplyFan-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1165 } -- 1.3.6.1.4.1.9839.1.2.1166.0 aL-LP-Lock-Comp-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1166 } -- 1.3.6.1.4.1.9839.1.2.1167.0 al-LowP-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1167 } -- 1.3.6.1.4.1.9839.1.2.1168.0 al-LowP-Lim-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1168 } -- 1.3.6.1.4.1.9839.1.2.1169.0 al-Filt-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1169 } -- 1.3.6.1.4.1.9839.1.2.1170.0 al-Dust-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1170 } -- 1.3.6.1.4.1.9839.1.2.1171.0 al-MechanicalCoolDefect-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1171 } -- 1.3.6.1.4.1.9839.1.2.1172.0 al-Damper-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Damper-Alarm-Alarm-status" ::= { snmpVariables 1172 } -- 1.3.6.1.4.1.9839.1.2.1173.0 al-LowSupplyTemp-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1173 } -- 1.3.6.1.4.1.9839.1.2.1174.0 al-HiRoomTemp-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1174 } -- 1.3.6.1.4.1.9839.1.2.1175.0 al-LoRoomTemp-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1175 } -- 1.3.6.1.4.1.9839.1.2.1176.0 al-LowSH-1-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1176 } -- 1.3.6.1.4.1.9839.1.2.1177.0 al-LOP-1-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1177 } -- 1.3.6.1.4.1.9839.1.2.1178.0 al-MOP-1-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1178 } -- 1.3.6.1.4.1.9839.1.2.1179.0 al-LowSuct-1-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1179 } -- 1.3.6.1.4.1.9839.1.2.1180.0 al-EEV-1-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-EEV-Alarm-Alarm-status" ::= { snmpVariables 1180 } -- 1.3.6.1.4.1.9839.1.2.1181.0 al-EmergClos-1-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1181 } -- 1.3.6.1.4.1.9839.1.2.1182.0 al-ExpansionOffline-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1182 } -- 1.3.6.1.4.1.9839.1.2.1183.0 al-InvOffline-PWRP-1-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Inverter-Offline-Alarm-status" ::= { snmpVariables 1183 } -- 1.3.6.1.4.1.9839.1.2.1184.0 al-FilterAirPressPrb-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1184 } -- 1.3.6.1.4.1.9839.1.2.1185.0 al-PWRP-1-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1185 } -- 1.3.6.1.4.1.9839.1.2.1186.0 al-Condenser-dirty-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1186 } -- 1.3.6.1.4.1.9839.1.2.1187.0 al-HighDscgT-BLDC1-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1187 } -- 1.3.6.1.4.1.9839.1.2.1188.0 al-retain-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 1188 } -- 1.3.6.1.4.1.9839.1.2.1189.0 al-Err-retain-write-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 1189 } -- 1.3.6.1.4.1.9839.1.2.1190.0 al-SupplyTempPrb-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1190 } -- 1.3.6.1.4.1.9839.1.2.1191.0 al-RoomTempPrb-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1191 } -- 1.3.6.1.4.1.9839.1.2.1192.0 al-AmbTempPrb-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1192 } -- 1.3.6.1.4.1.9839.1.2.1193.0 al-CompHiP-Prb-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1193 } -- 1.3.6.1.4.1.9839.1.2.1194.0 al-DscgTempPrb-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1194 } -- 1.3.6.1.4.1.9839.1.2.1195.0 al-SuctP-Prb-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1195 } -- 1.3.6.1.4.1.9839.1.2.1196.0 al-SuctTemp-Prb-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1196 } -- 1.3.6.1.4.1.9839.1.2.1197.0 al-CondenTempPrb-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1197 } -- 1.3.6.1.4.1.9839.1.2.1198.0 al-AmbHumPrb-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1198 } -- 1.3.6.1.4.1.9839.1.2.1199.0 al-Smoke-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1199 } -- 1.3.6.1.4.1.9839.1.2.1200.0 al-OvldComp-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Inverter-Overload-Alarm-status" ::= { snmpVariables 1200 } -- 1.3.6.1.4.1.9839.1.2.1201.0 al-HiP-Sw-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1201 } -- 1.3.6.1.4.1.9839.1.2.1202.0 al-HiP-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1202 } -- 1.3.6.1.4.1.9839.1.2.1203.0 al-PwrFail-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1203 } -- 1.3.6.1.4.1.9839.1.2.1204.0 al-OvldSupplyFan-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1204 } -- 1.3.6.1.4.1.9839.1.2.1205.0 aL-LP-Lock-Comp-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1205 } -- 1.3.6.1.4.1.9839.1.2.1206.0 al-LowP-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1206 } -- 1.3.6.1.4.1.9839.1.2.1207.0 al-LowP-Lim-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1207 } -- 1.3.6.1.4.1.9839.1.2.1208.0 al-Filt-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1208 } -- 1.3.6.1.4.1.9839.1.2.1209.0 al-Dust-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1209 } -- 1.3.6.1.4.1.9839.1.2.1210.0 al-MechanicalCoolDefect-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1210 } -- 1.3.6.1.4.1.9839.1.2.1211.0 al-Damper-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Damper-Alarm-Alarm-status" ::= { snmpVariables 1211 } -- 1.3.6.1.4.1.9839.1.2.1212.0 al-LowSupplyTemp-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1212 } -- 1.3.6.1.4.1.9839.1.2.1213.0 al-HiRoomTemp-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1213 } -- 1.3.6.1.4.1.9839.1.2.1214.0 al-LoRoomTemp-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1214 } -- 1.3.6.1.4.1.9839.1.2.1215.0 al-LowSH-1-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1215 } -- 1.3.6.1.4.1.9839.1.2.1216.0 al-LOP-1-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1216 } -- 1.3.6.1.4.1.9839.1.2.1217.0 al-MOP-1-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1217 } -- 1.3.6.1.4.1.9839.1.2.1218.0 al-LowSuct-1-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1218 } -- 1.3.6.1.4.1.9839.1.2.1219.0 al-EEV-1-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-EEV-Alarm-Alarm-status" ::= { snmpVariables 1219 } -- 1.3.6.1.4.1.9839.1.2.1220.0 al-EmergClos-1-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1220 } -- 1.3.6.1.4.1.9839.1.2.1221.0 al-ExpansionOffline-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1221 } -- 1.3.6.1.4.1.9839.1.2.1222.0 al-InvOffline-PWRP-1-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Inverter-Offline-Alarm-status" ::= { snmpVariables 1222 } -- 1.3.6.1.4.1.9839.1.2.1223.0 al-FilterAirPressPrb-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1223 } -- 1.3.6.1.4.1.9839.1.2.1224.0 al-PWRP-1-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1224 } -- 1.3.6.1.4.1.9839.1.2.1225.0 al-Condenser-dirty-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1225 } -- 1.3.6.1.4.1.9839.1.2.1226.0 al-HighDscgT-BLDC1-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1226 } -- 1.3.6.1.4.1.9839.1.2.1227.0 al-retain-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 1227 } -- 1.3.6.1.4.1.9839.1.2.1228.0 al-Err-retain-write-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 1228 } -- 1.3.6.1.4.1.9839.1.2.1229.0 al-SupplyTempPrb-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1229 } -- 1.3.6.1.4.1.9839.1.2.1230.0 al-RoomTempPrb-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1230 } -- 1.3.6.1.4.1.9839.1.2.1231.0 al-AmbTempPrb-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1231 } -- 1.3.6.1.4.1.9839.1.2.1232.0 al-CompHiP-Prb-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1232 } -- 1.3.6.1.4.1.9839.1.2.1233.0 al-DscgTempPrb-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1233 } -- 1.3.6.1.4.1.9839.1.2.1234.0 al-SuctP-Prb-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1234 } -- 1.3.6.1.4.1.9839.1.2.1235.0 al-SuctTemp-Prb-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1235 } -- 1.3.6.1.4.1.9839.1.2.1236.0 al-CondenTempPrb-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1236 } -- 1.3.6.1.4.1.9839.1.2.1237.0 al-AmbHumPrb-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1237 } -- 1.3.6.1.4.1.9839.1.2.1238.0 al-Smoke-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1238 } -- 1.3.6.1.4.1.9839.1.2.1239.0 al-OvldComp-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Inverter-Overload-Alarm-status" ::= { snmpVariables 1239 } -- 1.3.6.1.4.1.9839.1.2.1240.0 al-HiP-Sw-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1240 } -- 1.3.6.1.4.1.9839.1.2.1241.0 al-HiP-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1241 } -- 1.3.6.1.4.1.9839.1.2.1242.0 al-PwrFail-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1242 } -- 1.3.6.1.4.1.9839.1.2.1243.0 al-OvldSupplyFan-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1243 } -- 1.3.6.1.4.1.9839.1.2.1244.0 aL-LP-Lock-Comp-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1244 } -- 1.3.6.1.4.1.9839.1.2.1245.0 al-LowP-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1245 } -- 1.3.6.1.4.1.9839.1.2.1246.0 al-LowP-Lim-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1246 } -- 1.3.6.1.4.1.9839.1.2.1247.0 al-Filt-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1247 } -- 1.3.6.1.4.1.9839.1.2.1248.0 al-Dust-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1248 } -- 1.3.6.1.4.1.9839.1.2.1249.0 al-MechanicalCoolDefect-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1249 } -- 1.3.6.1.4.1.9839.1.2.1250.0 al-Damper-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Damper-Alarm-Alarm-status" ::= { snmpVariables 1250 } -- 1.3.6.1.4.1.9839.1.2.1251.0 al-LowSupplyTemp-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1251 } -- 1.3.6.1.4.1.9839.1.2.1252.0 al-HiRoomTemp-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1252 } -- 1.3.6.1.4.1.9839.1.2.1253.0 al-LoRoomTemp-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1253 } -- 1.3.6.1.4.1.9839.1.2.1254.0 al-LowSH-1-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1254 } -- 1.3.6.1.4.1.9839.1.2.1255.0 al-LOP-1-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1255 } -- 1.3.6.1.4.1.9839.1.2.1256.0 al-MOP-1-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1256 } -- 1.3.6.1.4.1.9839.1.2.1257.0 al-LowSuct-1-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1257 } -- 1.3.6.1.4.1.9839.1.2.1258.0 al-EEV-1-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-EEV-Alarm-Alarm-status" ::= { snmpVariables 1258 } -- 1.3.6.1.4.1.9839.1.2.1259.0 al-EmergClos-1-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1259 } -- 1.3.6.1.4.1.9839.1.2.1260.0 al-ExpansionOffline-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1260 } -- 1.3.6.1.4.1.9839.1.2.1261.0 al-InvOffline-PWRP-1-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Inverter-Offline-Alarm-status" ::= { snmpVariables 1261 } -- 1.3.6.1.4.1.9839.1.2.1262.0 al-FilterAirPressPrb-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1262 } -- 1.3.6.1.4.1.9839.1.2.1263.0 al-PWRP-1-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1263 } -- 1.3.6.1.4.1.9839.1.2.1264.0 al-Condenser-dirty-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1264 } -- 1.3.6.1.4.1.9839.1.2.1265.0 al-HighDscgT-BLDC1-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1265 } -- 1.3.6.1.4.1.9839.1.2.1266.0 al-retain-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 1266 } -- 1.3.6.1.4.1.9839.1.2.1267.0 al-Err-retain-write-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 1267 } -- 1.3.6.1.4.1.9839.1.2.1268.0 al-SupplyTempPrb-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1268 } -- 1.3.6.1.4.1.9839.1.2.1269.0 al-RoomTempPrb-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1269 } -- 1.3.6.1.4.1.9839.1.2.1270.0 al-AmbTempPrb-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1270 } -- 1.3.6.1.4.1.9839.1.2.1271.0 al-CompHiP-Prb-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1271 } -- 1.3.6.1.4.1.9839.1.2.1272.0 al-DscgTempPrb-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1272 } -- 1.3.6.1.4.1.9839.1.2.1273.0 al-SuctP-Prb-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1273 } -- 1.3.6.1.4.1.9839.1.2.1274.0 al-SuctTemp-Prb-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1274 } -- 1.3.6.1.4.1.9839.1.2.1275.0 al-CondenTempPrb-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1275 } -- 1.3.6.1.4.1.9839.1.2.1276.0 al-AmbHumPrb-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1276 } -- 1.3.6.1.4.1.9839.1.2.1277.0 al-Smoke-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1277 } -- 1.3.6.1.4.1.9839.1.2.1278.0 al-OvldComp-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Inverter-Overload-Alarm-status" ::= { snmpVariables 1278 } -- 1.3.6.1.4.1.9839.1.2.1279.0 al-HiP-Sw-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1279 } -- 1.3.6.1.4.1.9839.1.2.1280.0 al-HiP-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1280 } -- 1.3.6.1.4.1.9839.1.2.1281.0 al-PwrFail-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1281 } -- 1.3.6.1.4.1.9839.1.2.1282.0 al-OvldSupplyFan-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1282 } -- 1.3.6.1.4.1.9839.1.2.1283.0 aL-LP-Lock-Comp-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1283 } -- 1.3.6.1.4.1.9839.1.2.1284.0 al-LowP-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1284 } -- 1.3.6.1.4.1.9839.1.2.1285.0 al-LowP-Lim-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1285 } -- 1.3.6.1.4.1.9839.1.2.1286.0 al-Filt-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1286 } -- 1.3.6.1.4.1.9839.1.2.1287.0 al-Dust-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1287 } -- 1.3.6.1.4.1.9839.1.2.1288.0 al-MechanicalCoolDefect-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1288 } -- 1.3.6.1.4.1.9839.1.2.1289.0 al-Damper-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Damper-Alarm-Alarm-status" ::= { snmpVariables 1289 } -- 1.3.6.1.4.1.9839.1.2.1290.0 al-LowSupplyTemp-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1290 } -- 1.3.6.1.4.1.9839.1.2.1291.0 al-HiRoomTemp-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1291 } -- 1.3.6.1.4.1.9839.1.2.1292.0 al-LoRoomTemp-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1292 } -- 1.3.6.1.4.1.9839.1.2.1293.0 al-LowSH-1-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1293 } -- 1.3.6.1.4.1.9839.1.2.1294.0 al-LOP-1-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1294 } -- 1.3.6.1.4.1.9839.1.2.1295.0 al-MOP-1-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1295 } -- 1.3.6.1.4.1.9839.1.2.1296.0 al-LowSuct-1-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1296 } -- 1.3.6.1.4.1.9839.1.2.1297.0 al-EEV-1-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-EEV-Alarm-Alarm-status" ::= { snmpVariables 1297 } -- 1.3.6.1.4.1.9839.1.2.1298.0 al-EmergClos-1-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1298 } -- 1.3.6.1.4.1.9839.1.2.1299.0 al-ExpansionOffline-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1299 } -- 1.3.6.1.4.1.9839.1.2.1300.0 al-InvOffline-PWRP-1-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Inverter-Offline-Alarm-status" ::= { snmpVariables 1300 } -- 1.3.6.1.4.1.9839.1.2.1301.0 al-FilterAirPressPrb-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1301 } -- 1.3.6.1.4.1.9839.1.2.1302.0 al-PWRP-1-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1302 } -- 1.3.6.1.4.1.9839.1.2.1303.0 al-Condenser-dirty-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1303 } -- 1.3.6.1.4.1.9839.1.2.1304.0 al-HighDscgT-BLDC1-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1304 } -- 1.3.6.1.4.1.9839.1.2.1305.0 al-retain-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 1305 } -- 1.3.6.1.4.1.9839.1.2.1306.0 al-Err-retain-write-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 1306 } -- 1.3.6.1.4.1.9839.1.2.1307.0 al-SupplyTempPrb-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1307 } -- 1.3.6.1.4.1.9839.1.2.1308.0 al-RoomTempPrb-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1308 } -- 1.3.6.1.4.1.9839.1.2.1309.0 al-AmbTempPrb-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1309 } -- 1.3.6.1.4.1.9839.1.2.1310.0 al-CompHiP-Prb-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1310 } -- 1.3.6.1.4.1.9839.1.2.1311.0 al-DscgTempPrb-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1311 } -- 1.3.6.1.4.1.9839.1.2.1312.0 al-SuctP-Prb-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1312 } -- 1.3.6.1.4.1.9839.1.2.1313.0 al-SuctTemp-Prb-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1313 } -- 1.3.6.1.4.1.9839.1.2.1314.0 al-CondenTempPrb-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1314 } -- 1.3.6.1.4.1.9839.1.2.1315.0 al-AmbHumPrb-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1315 } -- 1.3.6.1.4.1.9839.1.2.1316.0 al-Smoke-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1316 } -- 1.3.6.1.4.1.9839.1.2.1317.0 al-OvldComp-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Inverter-Overload-Alarm-status" ::= { snmpVariables 1317 } -- 1.3.6.1.4.1.9839.1.2.1318.0 al-HiP-Sw-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1318 } -- 1.3.6.1.4.1.9839.1.2.1319.0 al-HiP-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1319 } -- 1.3.6.1.4.1.9839.1.2.1320.0 al-PwrFail-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1320 } -- 1.3.6.1.4.1.9839.1.2.1321.0 al-OvldSupplyFan-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1321 } -- 1.3.6.1.4.1.9839.1.2.1322.0 aL-LP-Lock-Comp-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1322 } -- 1.3.6.1.4.1.9839.1.2.1323.0 al-LowP-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1323 } -- 1.3.6.1.4.1.9839.1.2.1324.0 al-LowP-Lim-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1324 } -- 1.3.6.1.4.1.9839.1.2.1325.0 al-Filt-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1325 } -- 1.3.6.1.4.1.9839.1.2.1326.0 al-Dust-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1326 } -- 1.3.6.1.4.1.9839.1.2.1327.0 al-MechanicalCoolDefect-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1327 } -- 1.3.6.1.4.1.9839.1.2.1328.0 al-Damper-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Damper-Alarm-Alarm-status" ::= { snmpVariables 1328 } -- 1.3.6.1.4.1.9839.1.2.1329.0 al-LowSupplyTemp-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1329 } -- 1.3.6.1.4.1.9839.1.2.1330.0 al-HiRoomTemp-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1330 } -- 1.3.6.1.4.1.9839.1.2.1331.0 al-LoRoomTemp-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1331 } -- 1.3.6.1.4.1.9839.1.2.1332.0 al-LowSH-1-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1332 } -- 1.3.6.1.4.1.9839.1.2.1333.0 al-LOP-1-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1333 } -- 1.3.6.1.4.1.9839.1.2.1334.0 al-MOP-1-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1334 } -- 1.3.6.1.4.1.9839.1.2.1335.0 al-LowSuct-1-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1335 } -- 1.3.6.1.4.1.9839.1.2.1336.0 al-EEV-1-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-EEV-Alarm-Alarm-status" ::= { snmpVariables 1336 } -- 1.3.6.1.4.1.9839.1.2.1337.0 al-EmergClos-1-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1337 } -- 1.3.6.1.4.1.9839.1.2.1338.0 al-ExpansionOffline-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1338 } -- 1.3.6.1.4.1.9839.1.2.1339.0 al-InvOffline-PWRP-1-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Inverter-Offline-Alarm-status" ::= { snmpVariables 1339 } -- 1.3.6.1.4.1.9839.1.2.1340.0 al-FilterAirPressPrb-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1340 } -- 1.3.6.1.4.1.9839.1.2.1341.0 al-PWRP-1-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1341 } -- 1.3.6.1.4.1.9839.1.2.1342.0 al-Condenser-dirty-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1342 } -- 1.3.6.1.4.1.9839.1.2.1343.0 al-HighDscgT-BLDC1-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1343 } -- 1.3.6.1.4.1.9839.1.2.1344.0 al-retain-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 1344 } -- 1.3.6.1.4.1.9839.1.2.1345.0 al-Err-retain-write-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 1345 } -- 1.3.6.1.4.1.9839.1.2.1346.0 al-SupplyTempPrb-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1346 } -- 1.3.6.1.4.1.9839.1.2.1347.0 al-RoomTempPrb-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1347 } -- 1.3.6.1.4.1.9839.1.2.1348.0 al-AmbTempPrb-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1348 } -- 1.3.6.1.4.1.9839.1.2.1349.0 al-CompHiP-Prb-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1349 } -- 1.3.6.1.4.1.9839.1.2.1350.0 al-DscgTempPrb-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1350 } -- 1.3.6.1.4.1.9839.1.2.1351.0 al-SuctP-Prb-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1351 } -- 1.3.6.1.4.1.9839.1.2.1352.0 al-SuctTemp-Prb-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1352 } -- 1.3.6.1.4.1.9839.1.2.1353.0 al-CondenTempPrb-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1353 } -- 1.3.6.1.4.1.9839.1.2.1354.0 al-AmbHumPrb-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1354 } -- 1.3.6.1.4.1.9839.1.2.1355.0 al-Smoke-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1355 } -- 1.3.6.1.4.1.9839.1.2.1356.0 al-OvldComp-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Inverter-Overload-Alarm-status" ::= { snmpVariables 1356 } -- 1.3.6.1.4.1.9839.1.2.1357.0 al-HiP-Sw-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1357 } -- 1.3.6.1.4.1.9839.1.2.1358.0 al-HiP-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1358 } -- 1.3.6.1.4.1.9839.1.2.1359.0 al-PwrFail-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1359 } -- 1.3.6.1.4.1.9839.1.2.1360.0 al-OvldSupplyFan-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1360 } -- 1.3.6.1.4.1.9839.1.2.1361.0 aL-LP-Lock-Comp-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1361 } -- 1.3.6.1.4.1.9839.1.2.1362.0 al-LowP-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1362 } -- 1.3.6.1.4.1.9839.1.2.1363.0 al-LowP-Lim-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1363 } -- 1.3.6.1.4.1.9839.1.2.1364.0 al-Filt-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1364 } -- 1.3.6.1.4.1.9839.1.2.1365.0 al-Dust-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1365 } -- 1.3.6.1.4.1.9839.1.2.1366.0 al-MechanicalCoolDefect-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1366 } -- 1.3.6.1.4.1.9839.1.2.1367.0 al-Damper-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Damper-Alarm-Alarm-status" ::= { snmpVariables 1367 } -- 1.3.6.1.4.1.9839.1.2.1368.0 al-LowSupplyTemp-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1368 } -- 1.3.6.1.4.1.9839.1.2.1369.0 al-HiRoomTemp-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1369 } -- 1.3.6.1.4.1.9839.1.2.1370.0 al-LoRoomTemp-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1370 } -- 1.3.6.1.4.1.9839.1.2.1371.0 al-LowSH-1-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1371 } -- 1.3.6.1.4.1.9839.1.2.1372.0 al-LOP-1-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1372 } -- 1.3.6.1.4.1.9839.1.2.1373.0 al-MOP-1-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1373 } -- 1.3.6.1.4.1.9839.1.2.1374.0 al-LowSuct-1-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1374 } -- 1.3.6.1.4.1.9839.1.2.1375.0 al-EEV-1-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-EEV-Alarm-Alarm-status" ::= { snmpVariables 1375 } -- 1.3.6.1.4.1.9839.1.2.1376.0 al-EmergClos-1-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1376 } -- 1.3.6.1.4.1.9839.1.2.1377.0 al-ExpansionOffline-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1377 } -- 1.3.6.1.4.1.9839.1.2.1378.0 al-InvOffline-PWRP-1-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Inverter-Offline-Alarm-status" ::= { snmpVariables 1378 } -- 1.3.6.1.4.1.9839.1.2.1379.0 al-FilterAirPressPrb-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1379 } -- 1.3.6.1.4.1.9839.1.2.1380.0 al-PWRP-1-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1380 } -- 1.3.6.1.4.1.9839.1.2.1381.0 al-Condenser-dirty-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1381 } -- 1.3.6.1.4.1.9839.1.2.1382.0 al-HighDscgT-BLDC1-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1382 } -- 1.3.6.1.4.1.9839.1.2.1383.0 al-retain-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 1383 } -- 1.3.6.1.4.1.9839.1.2.1384.0 al-Err-retain-write-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 1384 } -- 1.3.6.1.4.1.9839.1.2.1385.0 al-SupplyTempPrb-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1385 } -- 1.3.6.1.4.1.9839.1.2.1386.0 al-RoomTempPrb-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1386 } -- 1.3.6.1.4.1.9839.1.2.1387.0 al-AmbTempPrb-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1387 } -- 1.3.6.1.4.1.9839.1.2.1388.0 al-CompHiP-Prb-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1388 } -- 1.3.6.1.4.1.9839.1.2.1389.0 al-DscgTempPrb-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1389 } -- 1.3.6.1.4.1.9839.1.2.1390.0 al-SuctP-Prb-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1390 } -- 1.3.6.1.4.1.9839.1.2.1391.0 al-SuctTemp-Prb-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1391 } -- 1.3.6.1.4.1.9839.1.2.1392.0 al-CondenTempPrb-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1392 } -- 1.3.6.1.4.1.9839.1.2.1393.0 al-AmbHumPrb-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1393 } -- 1.3.6.1.4.1.9839.1.2.1394.0 al-Smoke-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1394 } -- 1.3.6.1.4.1.9839.1.2.1395.0 al-OvldComp-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Inverter-Overload-Alarm-status" ::= { snmpVariables 1395 } -- 1.3.6.1.4.1.9839.1.2.1396.0 al-HiP-Sw-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1396 } -- 1.3.6.1.4.1.9839.1.2.1397.0 al-HiP-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1397 } -- 1.3.6.1.4.1.9839.1.2.1398.0 al-PwrFail-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1398 } -- 1.3.6.1.4.1.9839.1.2.1399.0 al-OvldSupplyFan-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1399 } -- 1.3.6.1.4.1.9839.1.2.1400.0 aL-LP-Lock-Comp-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1400 } -- 1.3.6.1.4.1.9839.1.2.1401.0 al-LowP-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1401 } -- 1.3.6.1.4.1.9839.1.2.1402.0 al-LowP-Lim-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1402 } -- 1.3.6.1.4.1.9839.1.2.1403.0 al-Filt-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1403 } -- 1.3.6.1.4.1.9839.1.2.1404.0 al-Dust-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1404 } -- 1.3.6.1.4.1.9839.1.2.1405.0 al-MechanicalCoolDefect-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1405 } -- 1.3.6.1.4.1.9839.1.2.1406.0 al-Damper-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Damper-Alarm-Alarm-status" ::= { snmpVariables 1406 } -- 1.3.6.1.4.1.9839.1.2.1407.0 al-LowSupplyTemp-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1407 } -- 1.3.6.1.4.1.9839.1.2.1408.0 al-HiRoomTemp-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1408 } -- 1.3.6.1.4.1.9839.1.2.1409.0 al-LoRoomTemp-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1409 } -- 1.3.6.1.4.1.9839.1.2.1410.0 al-LowSH-1-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1410 } -- 1.3.6.1.4.1.9839.1.2.1411.0 al-LOP-1-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1411 } -- 1.3.6.1.4.1.9839.1.2.1412.0 al-MOP-1-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1412 } -- 1.3.6.1.4.1.9839.1.2.1413.0 al-LowSuct-1-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1413 } -- 1.3.6.1.4.1.9839.1.2.1414.0 al-EEV-1-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-EEV-Alarm-Alarm-status" ::= { snmpVariables 1414 } -- 1.3.6.1.4.1.9839.1.2.1415.0 al-EmergClos-1-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1415 } -- 1.3.6.1.4.1.9839.1.2.1416.0 al-ExpansionOffline-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1416 } -- 1.3.6.1.4.1.9839.1.2.1417.0 al-InvOffline-PWRP-1-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Inverter-Offline-Alarm-status" ::= { snmpVariables 1417 } -- 1.3.6.1.4.1.9839.1.2.1418.0 al-FilterAirPressPrb-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1418 } -- 1.3.6.1.4.1.9839.1.2.1419.0 al-PWRP-1-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1419 } -- 1.3.6.1.4.1.9839.1.2.1420.0 al-Condenser-dirty-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1420 } -- 1.3.6.1.4.1.9839.1.2.1421.0 al-HighDscgT-BLDC1-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1421 } -- 1.3.6.1.4.1.9839.1.2.1422.0 al-retain-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 1422 } -- 1.3.6.1.4.1.9839.1.2.1423.0 al-Err-retain-write-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 1423 } -- 1.3.6.1.4.1.9839.1.2.1424.0 al-SupplyTempPrb-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1424 } -- 1.3.6.1.4.1.9839.1.2.1425.0 al-RoomTempPrb-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1425 } -- 1.3.6.1.4.1.9839.1.2.1426.0 al-AmbTempPrb-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1426 } -- 1.3.6.1.4.1.9839.1.2.1427.0 al-CompHiP-Prb-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1427 } -- 1.3.6.1.4.1.9839.1.2.1428.0 al-DscgTempPrb-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1428 } -- 1.3.6.1.4.1.9839.1.2.1429.0 al-SuctP-Prb-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1429 } -- 1.3.6.1.4.1.9839.1.2.1430.0 al-SuctTemp-Prb-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1430 } -- 1.3.6.1.4.1.9839.1.2.1431.0 al-CondenTempPrb-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1431 } -- 1.3.6.1.4.1.9839.1.2.1432.0 al-AmbHumPrb-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1432 } -- 1.3.6.1.4.1.9839.1.2.1433.0 al-Smoke-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1433 } -- 1.3.6.1.4.1.9839.1.2.1434.0 al-OvldComp-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Inverter-Overload-Alarm-status" ::= { snmpVariables 1434 } -- 1.3.6.1.4.1.9839.1.2.1435.0 al-HiP-Sw-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1435 } -- 1.3.6.1.4.1.9839.1.2.1436.0 al-HiP-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1436 } -- 1.3.6.1.4.1.9839.1.2.1437.0 al-PwrFail-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1437 } -- 1.3.6.1.4.1.9839.1.2.1438.0 al-OvldSupplyFan-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1438 } -- 1.3.6.1.4.1.9839.1.2.1439.0 aL-LP-Lock-Comp-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1439 } -- 1.3.6.1.4.1.9839.1.2.1440.0 al-LowP-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1440 } -- 1.3.6.1.4.1.9839.1.2.1441.0 al-LowP-Lim-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1441 } -- 1.3.6.1.4.1.9839.1.2.1442.0 al-Filt-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1442 } -- 1.3.6.1.4.1.9839.1.2.1443.0 al-Dust-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1443 } -- 1.3.6.1.4.1.9839.1.2.1444.0 al-MechanicalCoolDefect-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1444 } -- 1.3.6.1.4.1.9839.1.2.1445.0 al-Damper-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Damper-Alarm-Alarm-status" ::= { snmpVariables 1445 } -- 1.3.6.1.4.1.9839.1.2.1446.0 al-LowSupplyTemp-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1446 } -- 1.3.6.1.4.1.9839.1.2.1447.0 al-HiRoomTemp-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1447 } -- 1.3.6.1.4.1.9839.1.2.1448.0 al-LoRoomTemp-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1448 } -- 1.3.6.1.4.1.9839.1.2.1449.0 al-LowSH-1-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1449 } -- 1.3.6.1.4.1.9839.1.2.1450.0 al-LOP-1-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1450 } -- 1.3.6.1.4.1.9839.1.2.1451.0 al-MOP-1-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1451 } -- 1.3.6.1.4.1.9839.1.2.1452.0 al-LowSuct-1-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1452 } -- 1.3.6.1.4.1.9839.1.2.1453.0 al-EEV-1-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-EEV-Alarm-Alarm-status" ::= { snmpVariables 1453 } -- 1.3.6.1.4.1.9839.1.2.1454.0 al-EmergClos-1-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1454 } -- 1.3.6.1.4.1.9839.1.2.1455.0 al-ExpansionOffline-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1455 } -- 1.3.6.1.4.1.9839.1.2.1456.0 al-InvOffline-PWRP-1-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Inverter-Offline-Alarm-status" ::= { snmpVariables 1456 } -- 1.3.6.1.4.1.9839.1.2.1457.0 al-FilterAirPressPrb-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1457 } -- 1.3.6.1.4.1.9839.1.2.1458.0 al-PWRP-1-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1458 } -- 1.3.6.1.4.1.9839.1.2.1459.0 al-Condenser-dirty-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1459 } -- 1.3.6.1.4.1.9839.1.2.1460.0 al-HighDscgT-BLDC1-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1460 } -- 1.3.6.1.4.1.9839.1.2.1461.0 al-retain-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 1461 } -- 1.3.6.1.4.1.9839.1.2.1462.0 al-Err-retain-write-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 1462 } -- 1.3.6.1.4.1.9839.1.2.1463.0 al-SupplyTempPrb-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1463 } -- 1.3.6.1.4.1.9839.1.2.1464.0 al-RoomTempPrb-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1464 } -- 1.3.6.1.4.1.9839.1.2.1465.0 al-AmbTempPrb-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1465 } -- 1.3.6.1.4.1.9839.1.2.1466.0 al-CompHiP-Prb-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1466 } -- 1.3.6.1.4.1.9839.1.2.1467.0 al-DscgTempPrb-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1467 } -- 1.3.6.1.4.1.9839.1.2.1468.0 al-SuctP-Prb-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1468 } -- 1.3.6.1.4.1.9839.1.2.1469.0 al-SuctTemp-Prb-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1469 } -- 1.3.6.1.4.1.9839.1.2.1470.0 al-CondenTempPrb-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1470 } -- 1.3.6.1.4.1.9839.1.2.1471.0 al-AmbHumPrb-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1471 } -- 1.3.6.1.4.1.9839.1.2.1472.0 al-Smoke-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1472 } -- 1.3.6.1.4.1.9839.1.2.1473.0 al-OvldComp-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Inverter-Overload-Alarm-status" ::= { snmpVariables 1473 } -- 1.3.6.1.4.1.9839.1.2.1474.0 al-HiP-Sw-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1474 } -- 1.3.6.1.4.1.9839.1.2.1475.0 al-HiP-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1475 } -- 1.3.6.1.4.1.9839.1.2.1476.0 al-PwrFail-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1476 } -- 1.3.6.1.4.1.9839.1.2.1477.0 al-OvldSupplyFan-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1477 } -- 1.3.6.1.4.1.9839.1.2.1478.0 aL-LP-Lock-Comp-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1478 } -- 1.3.6.1.4.1.9839.1.2.1479.0 al-LowP-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1479 } -- 1.3.6.1.4.1.9839.1.2.1480.0 al-LowP-Lim-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1480 } -- 1.3.6.1.4.1.9839.1.2.1481.0 al-Filt-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1481 } -- 1.3.6.1.4.1.9839.1.2.1482.0 al-Dust-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1482 } -- 1.3.6.1.4.1.9839.1.2.1483.0 al-MechanicalCoolDefect-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1483 } -- 1.3.6.1.4.1.9839.1.2.1484.0 al-Damper-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Damper-Alarm-Alarm-status" ::= { snmpVariables 1484 } -- 1.3.6.1.4.1.9839.1.2.1485.0 al-LowSupplyTemp-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1485 } -- 1.3.6.1.4.1.9839.1.2.1486.0 al-HiRoomTemp-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1486 } -- 1.3.6.1.4.1.9839.1.2.1487.0 al-LoRoomTemp-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1487 } -- 1.3.6.1.4.1.9839.1.2.1488.0 al-LowSH-1-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1488 } -- 1.3.6.1.4.1.9839.1.2.1489.0 al-LOP-1-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1489 } -- 1.3.6.1.4.1.9839.1.2.1490.0 al-MOP-1-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1490 } -- 1.3.6.1.4.1.9839.1.2.1491.0 al-LowSuct-1-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1491 } -- 1.3.6.1.4.1.9839.1.2.1492.0 al-EEV-1-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-EEV-Alarm-Alarm-status" ::= { snmpVariables 1492 } -- 1.3.6.1.4.1.9839.1.2.1493.0 al-EmergClos-1-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1493 } -- 1.3.6.1.4.1.9839.1.2.1494.0 al-ExpansionOffline-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1494 } -- 1.3.6.1.4.1.9839.1.2.1495.0 al-InvOffline-PWRP-1-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Inverter-Offline-Alarm-status" ::= { snmpVariables 1495 } -- 1.3.6.1.4.1.9839.1.2.1496.0 al-FilterAirPressPrb-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1496 } -- 1.3.6.1.4.1.9839.1.2.1497.0 al-PWRP-1-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1497 } -- 1.3.6.1.4.1.9839.1.2.1498.0 al-Condenser-dirty-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1498 } -- 1.3.6.1.4.1.9839.1.2.1499.0 al-HighDscgT-BLDC1-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1499 } -- 1.3.6.1.4.1.9839.1.2.1500.0 al-retain-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 1500 } -- 1.3.6.1.4.1.9839.1.2.1501.0 al-Err-retain-write-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 1501 } -- 1.3.6.1.4.1.9839.1.2.1502.0 al-SupplyTempPrb-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1502 } -- 1.3.6.1.4.1.9839.1.2.1503.0 al-RoomTempPrb-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1503 } -- 1.3.6.1.4.1.9839.1.2.1504.0 al-AmbTempPrb-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1504 } -- 1.3.6.1.4.1.9839.1.2.1505.0 al-CompHiP-Prb-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1505 } -- 1.3.6.1.4.1.9839.1.2.1506.0 al-DscgTempPrb-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1506 } -- 1.3.6.1.4.1.9839.1.2.1507.0 al-SuctP-Prb-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1507 } -- 1.3.6.1.4.1.9839.1.2.1508.0 al-SuctTemp-Prb-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1508 } -- 1.3.6.1.4.1.9839.1.2.1509.0 al-CondenTempPrb-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1509 } -- 1.3.6.1.4.1.9839.1.2.1510.0 al-AmbHumPrb-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1510 } -- 1.3.6.1.4.1.9839.1.2.1511.0 al-Smoke-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1511 } -- 1.3.6.1.4.1.9839.1.2.1512.0 al-OvldComp-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Inverter-Overload-Alarm-status" ::= { snmpVariables 1512 } -- 1.3.6.1.4.1.9839.1.2.1513.0 al-HiP-Sw-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1513 } -- 1.3.6.1.4.1.9839.1.2.1514.0 al-HiP-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1514 } -- 1.3.6.1.4.1.9839.1.2.1515.0 al-PwrFail-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1515 } -- 1.3.6.1.4.1.9839.1.2.1516.0 al-OvldSupplyFan-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1516 } -- 1.3.6.1.4.1.9839.1.2.1517.0 aL-LP-Lock-Comp-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1517 } -- 1.3.6.1.4.1.9839.1.2.1518.0 al-LowP-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1518 } -- 1.3.6.1.4.1.9839.1.2.1519.0 al-LowP-Lim-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1519 } -- 1.3.6.1.4.1.9839.1.2.1520.0 al-Filt-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1520 } -- 1.3.6.1.4.1.9839.1.2.1521.0 al-Dust-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1521 } -- 1.3.6.1.4.1.9839.1.2.1522.0 al-MechanicalCoolDefect-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1522 } -- 1.3.6.1.4.1.9839.1.2.1523.0 al-Damper-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Damper-Alarm-Alarm-status" ::= { snmpVariables 1523 } -- 1.3.6.1.4.1.9839.1.2.1524.0 al-LowSupplyTemp-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1524 } -- 1.3.6.1.4.1.9839.1.2.1525.0 al-HiRoomTemp-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1525 } -- 1.3.6.1.4.1.9839.1.2.1526.0 al-LoRoomTemp-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1526 } -- 1.3.6.1.4.1.9839.1.2.1527.0 al-LowSH-1-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1527 } -- 1.3.6.1.4.1.9839.1.2.1528.0 al-LOP-1-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1528 } -- 1.3.6.1.4.1.9839.1.2.1529.0 al-MOP-1-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1529 } -- 1.3.6.1.4.1.9839.1.2.1530.0 al-LowSuct-1-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1530 } -- 1.3.6.1.4.1.9839.1.2.1531.0 al-EEV-1-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-EEV-Alarm-Alarm-status" ::= { snmpVariables 1531 } -- 1.3.6.1.4.1.9839.1.2.1532.0 al-EmergClos-1-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1532 } -- 1.3.6.1.4.1.9839.1.2.1533.0 al-ExpansionOffline-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1533 } -- 1.3.6.1.4.1.9839.1.2.1534.0 al-InvOffline-PWRP-1-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Inverter-Offline-Alarm-status" ::= { snmpVariables 1534 } -- 1.3.6.1.4.1.9839.1.2.1535.0 al-FilterAirPressPrb-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1535 } -- 1.3.6.1.4.1.9839.1.2.1536.0 al-PWRP-1-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1536 } -- 1.3.6.1.4.1.9839.1.2.1537.0 al-Condenser-dirty-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1537 } -- 1.3.6.1.4.1.9839.1.2.1538.0 al-HighDscgT-BLDC1-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1538 } -- 1.3.6.1.4.1.9839.1.2.1539.0 al-retain-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpVariables 1539 } -- 1.3.6.1.4.1.9839.1.2.1540.0 al-Err-retain-write-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpVariables 1540 } -- 1.3.6.1.4.1.9839.1.2.1541.0 al-SupplyTempPrb-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1541 } -- 1.3.6.1.4.1.9839.1.2.1542.0 al-RoomTempPrb-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1542 } -- 1.3.6.1.4.1.9839.1.2.1543.0 al-AmbTempPrb-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1543 } -- 1.3.6.1.4.1.9839.1.2.1544.0 al-CompHiP-Prb-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1544 } -- 1.3.6.1.4.1.9839.1.2.1545.0 al-DscgTempPrb-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1545 } -- 1.3.6.1.4.1.9839.1.2.1546.0 al-SuctP-Prb-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpVariables 1546 } -- 1.3.6.1.4.1.9839.1.2.1547.0 al-SuctTemp-Prb-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1547 } -- 1.3.6.1.4.1.9839.1.2.1548.0 al-CondenTempPrb-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpVariables 1548 } -- 1.3.6.1.4.1.9839.1.2.1549.0 al-AmbHumPrb-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Humidity-Alarm-Alarm-status" ::= { snmpVariables 1549 } -- 1.3.6.1.4.1.9839.1.2.1550.0 al-Smoke-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Smoke-Fire-alarm-Alarm-status" ::= { snmpVariables 1550 } -- 1.3.6.1.4.1.9839.1.2.1551.0 al-OvldComp-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Inverter-Overload-Alarm-status" ::= { snmpVariables 1551 } -- 1.3.6.1.4.1.9839.1.2.1552.0 al-HiP-Sw-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-High-Pressure-Switch-Error-Alarm-status" ::= { snmpVariables 1552 } -- 1.3.6.1.4.1.9839.1.2.1553.0 al-HiP-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-High-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1553 } -- 1.3.6.1.4.1.9839.1.2.1554.0 al-PwrFail-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-DC-Failover-Active-Alarm-status" ::= { snmpVariables 1554 } -- 1.3.6.1.4.1.9839.1.2.1555.0 al-OvldSupplyFan-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Supply-Fan-Overload-Alarm-status" ::= { snmpVariables 1555 } -- 1.3.6.1.4.1.9839.1.2.1556.0 aL-LP-Lock-Comp-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Low-Press-Lockout-Alarm-status" ::= { snmpVariables 1556 } -- 1.3.6.1.4.1.9839.1.2.1557.0 al-LowP-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Low-Pressure-Alarm-Alarm-status" ::= { snmpVariables 1557 } -- 1.3.6.1.4.1.9839.1.2.1558.0 al-LowP-Lim-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpVariables 1558 } -- 1.3.6.1.4.1.9839.1.2.1559.0 al-Filt-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Dirty-Filter-Alarm-Alarm-status" ::= { snmpVariables 1559 } -- 1.3.6.1.4.1.9839.1.2.1560.0 al-Dust-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-AFPD-Triggered-Alarm-status" ::= { snmpVariables 1560 } -- 1.3.6.1.4.1.9839.1.2.1561.0 al-MechanicalCoolDefect-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1561 } -- 1.3.6.1.4.1.9839.1.2.1562.0 al-Damper-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Damper-Alarm-Alarm-status" ::= { snmpVariables 1562 } -- 1.3.6.1.4.1.9839.1.2.1563.0 al-LowSupplyTemp-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1563 } -- 1.3.6.1.4.1.9839.1.2.1564.0 al-HiRoomTemp-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-High-Temp-Alarm-Alarm-status" ::= { snmpVariables 1564 } -- 1.3.6.1.4.1.9839.1.2.1565.0 al-LoRoomTemp-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Low-Temp-Alarm-Alarm-status" ::= { snmpVariables 1565 } -- 1.3.6.1.4.1.9839.1.2.1566.0 al-LowSH-1-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Low-Superheat-Alarm-Alarm-status" ::= { snmpVariables 1566 } -- 1.3.6.1.4.1.9839.1.2.1567.0 al-LOP-1-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1567 } -- 1.3.6.1.4.1.9839.1.2.1568.0 al-MOP-1-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1568 } -- 1.3.6.1.4.1.9839.1.2.1569.0 al-LowSuct-1-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpVariables 1569 } -- 1.3.6.1.4.1.9839.1.2.1570.0 al-EEV-1-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-EEV-Alarm-Alarm-status" ::= { snmpVariables 1570 } -- 1.3.6.1.4.1.9839.1.2.1571.0 al-EmergClos-1-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Emergency-Ventilation-Active-Alarm-status" ::= { snmpVariables 1571 } -- 1.3.6.1.4.1.9839.1.2.1572.0 al-ExpansionOffline-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Expansion-Board-Offline-Alarm-status" ::= { snmpVariables 1572 } -- 1.3.6.1.4.1.9839.1.2.1573.0 al-InvOffline-PWRP-1-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Inverter-Offline-Alarm-status" ::= { snmpVariables 1573 } -- 1.3.6.1.4.1.9839.1.2.1574.0 al-FilterAirPressPrb-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpVariables 1574 } -- 1.3.6.1.4.1.9839.1.2.1575.0 al-PWRP-1-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-BLDC-Alarm-Alarm-status" ::= { snmpVariables 1575 } -- 1.3.6.1.4.1.9839.1.2.1576.0 al-Condenser-dirty-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Dirty-Condenser-Alarm-status" ::= { snmpVariables 1576 } -- 1.3.6.1.4.1.9839.1.2.1577.0 al-HighDscgT-BLDC1-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpVariables 1577 } -- 1.3.6.1.4.1.9839.1.2.1578.0 unit-Model-List-0- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Unit-Model" DEFVAL {2} ::= { snmpVariables 1578 } -- 1.3.6.1.4.1.9839.1.2.1579.0 unit-Model-List-1- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Unit-Model" DEFVAL {2} ::= { snmpVariables 1579 } -- 1.3.6.1.4.1.9839.1.2.1580.0 unit-Model-List-2- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Unit-Model" DEFVAL {2} ::= { snmpVariables 1580 } -- 1.3.6.1.4.1.9839.1.2.1581.0 unit-Model-List-3- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Unit-Model" DEFVAL {2} ::= { snmpVariables 1581 } -- 1.3.6.1.4.1.9839.1.2.1582.0 unit-Model-List-4- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Unit-Model" DEFVAL {2} ::= { snmpVariables 1582 } -- 1.3.6.1.4.1.9839.1.2.1583.0 unit-Model-List-5- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Unit-Model" DEFVAL {2} ::= { snmpVariables 1583 } -- 1.3.6.1.4.1.9839.1.2.1584.0 unit-Model-List-6- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Unit-Model" DEFVAL {2} ::= { snmpVariables 1584 } -- 1.3.6.1.4.1.9839.1.2.1585.0 unit-Model-List-7- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Unit-Model" DEFVAL {2} ::= { snmpVariables 1585 } -- 1.3.6.1.4.1.9839.1.2.1586.0 unit-Model-List-8- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Unit-Model" DEFVAL {2} ::= { snmpVariables 1586 } -- 1.3.6.1.4.1.9839.1.2.1587.0 unit-Model-List-9- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Unit-Model" DEFVAL {2} ::= { snmpVariables 1587 } -- 1.3.6.1.4.1.9839.1.2.1588.0 unit-Model-List-10- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Unit-Model" DEFVAL {2} ::= { snmpVariables 1588 } -- 1.3.6.1.4.1.9839.1.2.1589.0 unit-Model-List-11- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Unit-Model" DEFVAL {2} ::= { snmpVariables 1589 } -- 1.3.6.1.4.1.9839.1.2.1590.0 unit-Model-List-12- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Unit-Model" DEFVAL {2} ::= { snmpVariables 1590 } -- 1.3.6.1.4.1.9839.1.2.1591.0 unit-Model-List-13- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Unit-Model" DEFVAL {2} ::= { snmpVariables 1591 } -- 1.3.6.1.4.1.9839.1.2.1592.0 unit-Model-List-14- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Unit-Model" DEFVAL {2} ::= { snmpVariables 1592 } -- 1.3.6.1.4.1.9839.1.2.1593.0 unit-Model-List-15- OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Unit-Model" DEFVAL {2} ::= { snmpVariables 1593 } -- 1.3.6.1.4.1.9839.1.2.1594.0 generalMng-SoftwareVersion OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Software-Version-This-will-be-read-as-integer32-for-example-1500800-The-actual-version-would-be-1-5-008-00" ::= { snmpVariables 1594 } -- 1.3.6.1.4.1.9839.1.2.1595.0 cT-Value-List-0- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-CT-Value" ::= { snmpVariables 1595 } -- 1.3.6.1.4.1.9839.1.2.1596.0 cT-Value-List-1- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-CT-Value" ::= { snmpVariables 1596 } -- 1.3.6.1.4.1.9839.1.2.1597.0 cT-Value-List-2- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-CT-Value" ::= { snmpVariables 1597 } -- 1.3.6.1.4.1.9839.1.2.1598.0 cT-Value-List-3- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-CT-Value" ::= { snmpVariables 1598 } -- 1.3.6.1.4.1.9839.1.2.1599.0 cT-Value-List-4- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-CT-Value" ::= { snmpVariables 1599 } -- 1.3.6.1.4.1.9839.1.2.1600.0 cT-Value-List-5- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-CT-Value" ::= { snmpVariables 1600 } -- 1.3.6.1.4.1.9839.1.2.1601.0 cT-Value-List-6- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-CT-Value" ::= { snmpVariables 1601 } -- 1.3.6.1.4.1.9839.1.2.1602.0 cT-Value-List-7- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-CT-Value" ::= { snmpVariables 1602 } -- 1.3.6.1.4.1.9839.1.2.1603.0 cT-Value-List-8- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-CT-Value" ::= { snmpVariables 1603 } -- 1.3.6.1.4.1.9839.1.2.1604.0 cT-Value-List-9- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-CT-Value" ::= { snmpVariables 1604 } -- 1.3.6.1.4.1.9839.1.2.1605.0 cT-Value-List-10- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-CT-Value" ::= { snmpVariables 1605 } -- 1.3.6.1.4.1.9839.1.2.1606.0 cT-Value-List-11- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-CT-Value" ::= { snmpVariables 1606 } -- 1.3.6.1.4.1.9839.1.2.1607.0 cT-Value-List-12- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-CT-Value" ::= { snmpVariables 1607 } -- 1.3.6.1.4.1.9839.1.2.1608.0 cT-Value-List-13- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-CT-Value" ::= { snmpVariables 1608 } -- 1.3.6.1.4.1.9839.1.2.1609.0 cT-Value-List-14- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-CT-Value" ::= { snmpVariables 1609 } -- 1.3.6.1.4.1.9839.1.2.1610.0 cT-Value-List-15- OBJECT-TYPE SYNTAX Integer32 (-32768..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-CT-Value" ::= { snmpVariables 1610 } -- 1.3.6.1.4.1.9839.1.2.1611.0 al-CT-Transducer-Fail-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "Reversed" ::= { snmpVariables 1611 } -- 1.3.6.1.4.1.9839.1.2.1612.0 al-CT-Transducer-Fail-M01-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1612 } -- 1.3.6.1.4.1.9839.1.2.1613.0 al-CT-Transducer-Fail-M02-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1613 } -- 1.3.6.1.4.1.9839.1.2.1614.0 al-CT-Transducer-Fail-M03-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1614 } -- 1.3.6.1.4.1.9839.1.2.1615.0 al-CT-Transducer-Fail-M04-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1615 } -- 1.3.6.1.4.1.9839.1.2.1616.0 al-CT-Transducer-Fail-M05-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1616 } -- 1.3.6.1.4.1.9839.1.2.1617.0 al-CT-Transducer-Fail-M06-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1617 } -- 1.3.6.1.4.1.9839.1.2.1618.0 al-CT-Transducer-Fail-M07-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1618 } -- 1.3.6.1.4.1.9839.1.2.1619.0 al-CT-Transducer-Fail-M08-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1619 } -- 1.3.6.1.4.1.9839.1.2.1620.0 al-CT-Transducer-Fail-M09-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1620 } -- 1.3.6.1.4.1.9839.1.2.1621.0 al-CT-Transducer-Fail-M10-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1621 } -- 1.3.6.1.4.1.9839.1.2.1622.0 al-CT-Transducer-Fail-M11-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1622 } -- 1.3.6.1.4.1.9839.1.2.1623.0 al-CT-Transducer-Fail-M12-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1623 } -- 1.3.6.1.4.1.9839.1.2.1624.0 al-CT-Transducer-Fail-M13-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1624 } -- 1.3.6.1.4.1.9839.1.2.1625.0 al-CT-Transducer-Fail-M14-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1625 } -- 1.3.6.1.4.1.9839.1.2.1626.0 al-CT-Transducer-Fail-M15-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1626 } -- 1.3.6.1.4.1.9839.1.2.1627.0 al-CT-Transducer-Fail-M16-Active OBJECT-TYPE SYNTAX BITS MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Current-Transducer-Alarm-Alarm-status" ::= { snmpVariables 1627 } -- 1.3.6.1.4.1.9839.1.2.1628.0 unit-SN-List-0- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-1-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1628 } -- 1.3.6.1.4.1.9839.1.2.1629.0 unit-SN-List-1- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-2-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1629 } -- 1.3.6.1.4.1.9839.1.2.1630.0 unit-SN-List-2- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-3-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1630 } -- 1.3.6.1.4.1.9839.1.2.1631.0 unit-SN-List-3- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-4-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1631 } -- 1.3.6.1.4.1.9839.1.2.1632.0 unit-SN-List-4- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-5-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1632 } -- 1.3.6.1.4.1.9839.1.2.1633.0 unit-SN-List-5- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-6-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1633 } -- 1.3.6.1.4.1.9839.1.2.1634.0 unit-SN-List-6- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-7-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1634 } -- 1.3.6.1.4.1.9839.1.2.1635.0 unit-SN-List-7- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-8-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1635 } -- 1.3.6.1.4.1.9839.1.2.1636.0 unit-SN-List-8- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-9-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1636 } -- 1.3.6.1.4.1.9839.1.2.1637.0 unit-SN-List-9- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-10-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1637 } -- 1.3.6.1.4.1.9839.1.2.1638.0 unit-SN-List-10- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-11-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1638 } -- 1.3.6.1.4.1.9839.1.2.1639.0 unit-SN-List-11- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-12-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1639 } -- 1.3.6.1.4.1.9839.1.2.1640.0 unit-SN-List-12- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-13-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1640 } -- 1.3.6.1.4.1.9839.1.2.1641.0 unit-SN-List-13- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-14-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1641 } -- 1.3.6.1.4.1.9839.1.2.1642.0 unit-SN-List-14- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-15-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1642 } -- 1.3.6.1.4.1.9839.1.2.1643.0 unit-SN-List-15- OBJECT-TYPE SYNTAX Integer32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "HVAC-16-Serial-Number-This-will-be-available-if-SN-has-been-entered-after-install-" ::= { snmpVariables 1643 } -- 1.3.6.1.4.1.9839.1.2.1644.0 roomTemp-SNMP-Value OBJECT-TYPE SYNTAX Float MAX-ACCESS read-write STATUS current DESCRIPTION "Standalone-HVAC-Room-Temp-Sensor-Overwrite-for-direct-HVAC-control-Unit-0-1F" DEFVAL {-35} ::= { snmpVariables 1644 } -- 1.3.6.1.4.1.9839.1.2.1645.0 roomTemp-SNMP-Req OBJECT-TYPE SYNTAX Integer32 (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Standalone-HVAC-Room-Temp-Overwrite-Confirmation-Write-1-for-3-sec-at-least-once-every-15min-to-maintain-room-temp-sensor-overwrite" DEFVAL {0} ::= { snmpVariables 1645 } -- 1.3.6.1.4.1.9839.1.2.1856.0 roomHumASMUC OBJECT-TYPE SYNTAX Integer32 (-1000..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Room-Humidity-When-Reading-From-ASMUC" ::= { snmpVariables 1856 } -- 1.3.6.1.4.1.9839.1000 snmpTraps OBJECT IDENTIFIER ::= { sNMP 1000 } -- 1.3.6.1.4.1.9839.1000.1 trapV1-1 NOTIFICATION-TYPE OBJECTS { al-retain-Active } STATUS current DESCRIPTION "Too-Many-Internal-Memory-Writes-Controller-Alarm-Status" ::= { snmpTraps 1 } -- 1.3.6.1.4.1.9839.1000.2 trapV1-2 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-Active } STATUS current DESCRIPTION "Internal-Memory-Read-Write-Error-Controller-Alarm-Status" ::= { snmpTraps 2 } -- 1.3.6.1.4.1.9839.1000.3 trapV1-3 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-Active } STATUS current DESCRIPTION "Outdoor-Temperature-Sensor-Error-Controller-Alarm-Status" ::= { snmpTraps 3 } -- 1.3.6.1.4.1.9839.1000.4 trapV1-4 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 4 } -- 1.3.6.1.4.1.9839.1000.5 trapV1-5 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb1-Active } STATUS current DESCRIPTION "Indoor-Temperature-Sensor1-Error-Controller-Alarm-Status" ::= { snmpTraps 5 } -- 1.3.6.1.4.1.9839.1000.6 trapV1-6 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb2-Active } STATUS current DESCRIPTION "Indoor-Temperature-Sensor2-Error-Controller-Alarm-Status" ::= { snmpTraps 6 } -- 1.3.6.1.4.1.9839.1000.7 trapV1-7 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb3-Active } STATUS current DESCRIPTION "Indoor-Temperature-Sensor3-Error-Controller-Alarm-Status" ::= { snmpTraps 7 } -- 1.3.6.1.4.1.9839.1000.8 trapV1-8 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb4-Active } STATUS current DESCRIPTION "Indoor-Temperature-Sensor4-Error-Controller-Alarm-Status" ::= { snmpTraps 8 } -- 1.3.6.1.4.1.9839.1000.9 trapV1-9 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-Active } STATUS current DESCRIPTION "Humidity-Sensor-Alarm-Controller-Alarm-Status" ::= { snmpTraps 9 } -- 1.3.6.1.4.1.9839.1000.10 trapV1-10 NOTIFICATION-TYPE OBJECTS { al-Smoke-Active } STATUS current DESCRIPTION "Smoke-Fire-alarm-Controller-Alarm-Status" ::= { snmpTraps 10 } -- 1.3.6.1.4.1.9839.1000.11 trapV1-11 NOTIFICATION-TYPE OBJECTS { al-DG-Run-Active } STATUS current DESCRIPTION "Generator-Run-Controller-Alarm-Status" ::= { snmpTraps 11 } -- 1.3.6.1.4.1.9839.1000.12 trapV1-12 NOTIFICATION-TYPE OBJECTS { al-PwrFail-Active } STATUS current DESCRIPTION "DC-Failover-Active-Controller-Alarm-Status" ::= { snmpTraps 12 } -- 1.3.6.1.4.1.9839.1000.13 trapV1-13 NOTIFICATION-TYPE OBJECTS { al-AC-Fail-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 13 } -- 1.3.6.1.4.1.9839.1000.14 trapV1-14 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 14 } -- 1.3.6.1.4.1.9839.1000.15 trapV1-15 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-Active } STATUS current DESCRIPTION "High-Temp-Alarm-Controller-Alarm-Status" ::= { snmpTraps 15 } -- 1.3.6.1.4.1.9839.1000.16 trapV1-16 NOTIFICATION-TYPE OBJECTS { al-Hydric-Active } STATUS current DESCRIPTION "Hydrogen-Alarm-Controller-Alarm-Status" ::= { snmpTraps 16 } -- 1.3.6.1.4.1.9839.1000.17 trapV1-17 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-Active } STATUS current DESCRIPTION "Low-Temp-Alarm-Controller-Alarm-Status" ::= { snmpTraps 17 } -- 1.3.6.1.4.1.9839.1000.18 trapV1-18 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 18 } -- 1.3.6.1.4.1.9839.1000.19 trapV1-19 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave1-Active } STATUS current DESCRIPTION "HVAC-1-Offline-Alarm-Alarm-status" ::= { snmpTraps 19 } -- 1.3.6.1.4.1.9839.1000.20 trapV1-20 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave2-Active } STATUS current DESCRIPTION "HVAC-2-Offline-Alarm-Alarm-status" ::= { snmpTraps 20 } -- 1.3.6.1.4.1.9839.1000.21 trapV1-21 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave3-Active } STATUS current DESCRIPTION "HVAC-3-Offline-Alarm-Alarm-status" ::= { snmpTraps 21 } -- 1.3.6.1.4.1.9839.1000.22 trapV1-22 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave4-Active } STATUS current DESCRIPTION "HVAC-4-Offline-Alarm-Alarm-status" ::= { snmpTraps 22 } -- 1.3.6.1.4.1.9839.1000.23 trapV1-23 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave5-Active } STATUS current DESCRIPTION "HVAC-5-Offline-Alarm-Alarm-status" ::= { snmpTraps 23 } -- 1.3.6.1.4.1.9839.1000.24 trapV1-24 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave6-Active } STATUS current DESCRIPTION "HVAC-6-Offline-Alarm-Alarm-status" ::= { snmpTraps 24 } -- 1.3.6.1.4.1.9839.1000.25 trapV1-25 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave7-Active } STATUS current DESCRIPTION "HVAC-7-Offline-Alarm-Alarm-status" ::= { snmpTraps 25 } -- 1.3.6.1.4.1.9839.1000.26 trapV1-26 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave8-Active } STATUS current DESCRIPTION "HVAC-8-Offline-Alarm-Alarm-status" ::= { snmpTraps 26 } -- 1.3.6.1.4.1.9839.1000.27 trapV1-27 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave9-Active } STATUS current DESCRIPTION "HVAC-9-Offline-Alarm-Alarm-status" ::= { snmpTraps 27 } -- 1.3.6.1.4.1.9839.1000.28 trapV1-28 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave10-Active } STATUS current DESCRIPTION "HVAC-10-Offline-Alarm-Alarm-status" ::= { snmpTraps 28 } -- 1.3.6.1.4.1.9839.1000.29 trapV1-29 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave11-Active } STATUS current DESCRIPTION "HVAC-11-Offline-Alarm-Alarm-status" ::= { snmpTraps 29 } -- 1.3.6.1.4.1.9839.1000.30 trapV1-30 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave12-Active } STATUS current DESCRIPTION "HVAC-12-Offline-Alarm-Alarm-status" ::= { snmpTraps 30 } -- 1.3.6.1.4.1.9839.1000.31 trapV1-31 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave13-Active } STATUS current DESCRIPTION "HVAC-13-Offline-Alarm-Alarm-status" ::= { snmpTraps 31 } -- 1.3.6.1.4.1.9839.1000.32 trapV1-32 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave14-Active } STATUS current DESCRIPTION "HVAC-14-Offline-Alarm-Alarm-status" ::= { snmpTraps 32 } -- 1.3.6.1.4.1.9839.1000.33 trapV1-33 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave15-Active } STATUS current DESCRIPTION "HVAC-15-Offline-Alarm-Alarm-status" ::= { snmpTraps 33 } -- 1.3.6.1.4.1.9839.1000.34 trapV1-34 NOTIFICATION-TYPE OBJECTS { al-OfflineSlave16-Active } STATUS current DESCRIPTION "HVAC-16-Offline-Alarm-Alarm-status" ::= { snmpTraps 34 } -- 1.3.6.1.4.1.9839.1000.35 trapV1-35 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 35 } -- 1.3.6.1.4.1.9839.1000.36 trapV1-36 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave2-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 36 } -- 1.3.6.1.4.1.9839.1000.37 trapV1-37 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave3-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 37 } -- 1.3.6.1.4.1.9839.1000.38 trapV1-38 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave4-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 38 } -- 1.3.6.1.4.1.9839.1000.39 trapV1-39 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave5-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 39 } -- 1.3.6.1.4.1.9839.1000.40 trapV1-40 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave6-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 40 } -- 1.3.6.1.4.1.9839.1000.41 trapV1-41 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave7-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 41 } -- 1.3.6.1.4.1.9839.1000.42 trapV1-42 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave8-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 42 } -- 1.3.6.1.4.1.9839.1000.43 trapV1-43 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave9-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 43 } -- 1.3.6.1.4.1.9839.1000.44 trapV1-44 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave10-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 44 } -- 1.3.6.1.4.1.9839.1000.45 trapV1-45 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave11-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 45 } -- 1.3.6.1.4.1.9839.1000.46 trapV1-46 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave12-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 46 } -- 1.3.6.1.4.1.9839.1000.47 trapV1-47 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave13-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 47 } -- 1.3.6.1.4.1.9839.1000.48 trapV1-48 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave14-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 48 } -- 1.3.6.1.4.1.9839.1000.49 trapV1-49 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave15-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 49 } -- 1.3.6.1.4.1.9839.1000.50 trapV1-50 NOTIFICATION-TYPE OBJECTS { al-GenAlrmSlave16-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 50 } -- 1.3.6.1.4.1.9839.1000.51 trapV1-51 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 51 } -- 1.3.6.1.4.1.9839.1000.52 trapV1-52 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 52 } -- 1.3.6.1.4.1.9839.1000.53 trapV1-53 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 53 } -- 1.3.6.1.4.1.9839.1000.54 trapV1-54 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 54 } -- 1.3.6.1.4.1.9839.1000.55 trapV1-55 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 55 } -- 1.3.6.1.4.1.9839.1000.56 trapV1-56 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 56 } -- 1.3.6.1.4.1.9839.1000.57 trapV1-57 NOTIFICATION-TYPE OBJECTS { al-OvldComp-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 57 } -- 1.3.6.1.4.1.9839.1000.58 trapV1-58 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 58 } -- 1.3.6.1.4.1.9839.1000.59 trapV1-59 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 59 } -- 1.3.6.1.4.1.9839.1000.60 trapV1-60 NOTIFICATION-TYPE OBJECTS { al-HiP-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 60 } -- 1.3.6.1.4.1.9839.1000.61 trapV1-61 NOTIFICATION-TYPE OBJECTS { al-LowP-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 61 } -- 1.3.6.1.4.1.9839.1000.62 trapV1-62 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 62 } -- 1.3.6.1.4.1.9839.1000.63 trapV1-63 NOTIFICATION-TYPE OBJECTS { al-Filt-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 63 } -- 1.3.6.1.4.1.9839.1000.64 trapV1-64 NOTIFICATION-TYPE OBJECTS { al-Dust-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 64 } -- 1.3.6.1.4.1.9839.1000.65 trapV1-65 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 65 } -- 1.3.6.1.4.1.9839.1000.66 trapV1-66 NOTIFICATION-TYPE OBJECTS { al-Damper-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 66 } -- 1.3.6.1.4.1.9839.1000.67 trapV1-67 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 67 } -- 1.3.6.1.4.1.9839.1000.68 trapV1-68 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 68 } -- 1.3.6.1.4.1.9839.1000.69 trapV1-69 NOTIFICATION-TYPE OBJECTS { al-MasterOffline-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 69 } -- 1.3.6.1.4.1.9839.1000.70 trapV1-70 NOTIFICATION-TYPE OBJECTS { al-StartFailRetry-BLDC1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 70 } -- 1.3.6.1.4.1.9839.1000.71 trapV1-71 NOTIFICATION-TYPE OBJECTS { al-StartFailLock-BLDC1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 71 } -- 1.3.6.1.4.1.9839.1000.72 trapV1-72 NOTIFICATION-TYPE OBJECTS { al-LowDeltaP-BLDC1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 72 } -- 1.3.6.1.4.1.9839.1000.73 trapV1-73 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 73 } -- 1.3.6.1.4.1.9839.1000.74 trapV1-74 NOTIFICATION-TYPE OBJECTS { alEnv02-HighRatio-BLDC-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 74 } -- 1.3.6.1.4.1.9839.1000.75 trapV1-75 NOTIFICATION-TYPE OBJECTS { alEnv03-HighDscg-BLDC-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 75 } -- 1.3.6.1.4.1.9839.1000.76 trapV1-76 NOTIFICATION-TYPE OBJECTS { alEnv04-HighCurr-BLDC-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 76 } -- 1.3.6.1.4.1.9839.1000.77 trapV1-77 NOTIFICATION-TYPE OBJECTS { alEnv05-HighSuct-BLDC-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 77 } -- 1.3.6.1.4.1.9839.1000.78 trapV1-78 NOTIFICATION-TYPE OBJECTS { alEnv06-LowRatio-BLDC-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 78 } -- 1.3.6.1.4.1.9839.1000.79 trapV1-79 NOTIFICATION-TYPE OBJECTS { aLEnv07-LowDP-BLDC-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 79 } -- 1.3.6.1.4.1.9839.1000.80 trapV1-80 NOTIFICATION-TYPE OBJECTS { alEnv08-LowDscg-BLDC-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 80 } -- 1.3.6.1.4.1.9839.1000.81 trapV1-81 NOTIFICATION-TYPE OBJECTS { alEnv09-LowSuct-BLDC-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 81 } -- 1.3.6.1.4.1.9839.1000.82 trapV1-82 NOTIFICATION-TYPE OBJECTS { alEnv10-HDT-BLDC-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 82 } -- 1.3.6.1.4.1.9839.1000.83 trapV1-83 NOTIFICATION-TYPE OBJECTS { al01-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 83 } -- 1.3.6.1.4.1.9839.1000.84 trapV1-84 NOTIFICATION-TYPE OBJECTS { al02-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 84 } -- 1.3.6.1.4.1.9839.1000.85 trapV1-85 NOTIFICATION-TYPE OBJECTS { al03-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 85 } -- 1.3.6.1.4.1.9839.1000.86 trapV1-86 NOTIFICATION-TYPE OBJECTS { al04-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 86 } -- 1.3.6.1.4.1.9839.1000.87 trapV1-87 NOTIFICATION-TYPE OBJECTS { al05-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 87 } -- 1.3.6.1.4.1.9839.1000.88 trapV1-88 NOTIFICATION-TYPE OBJECTS { al06-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 88 } -- 1.3.6.1.4.1.9839.1000.89 trapV1-89 NOTIFICATION-TYPE OBJECTS { al07-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 89 } -- 1.3.6.1.4.1.9839.1000.90 trapV1-90 NOTIFICATION-TYPE OBJECTS { al08-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 90 } -- 1.3.6.1.4.1.9839.1000.91 trapV1-91 NOTIFICATION-TYPE OBJECTS { al09-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 91 } -- 1.3.6.1.4.1.9839.1000.92 trapV1-92 NOTIFICATION-TYPE OBJECTS { al10-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 92 } -- 1.3.6.1.4.1.9839.1000.93 trapV1-93 NOTIFICATION-TYPE OBJECTS { al11-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 93 } -- 1.3.6.1.4.1.9839.1000.94 trapV1-94 NOTIFICATION-TYPE OBJECTS { al12-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 94 } -- 1.3.6.1.4.1.9839.1000.95 trapV1-95 NOTIFICATION-TYPE OBJECTS { al13-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 95 } -- 1.3.6.1.4.1.9839.1000.96 trapV1-96 NOTIFICATION-TYPE OBJECTS { al14-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 96 } -- 1.3.6.1.4.1.9839.1000.97 trapV1-97 NOTIFICATION-TYPE OBJECTS { al15-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 97 } -- 1.3.6.1.4.1.9839.1000.98 trapV1-98 NOTIFICATION-TYPE OBJECTS { al16-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 98 } -- 1.3.6.1.4.1.9839.1000.99 trapV1-99 NOTIFICATION-TYPE OBJECTS { al17-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 99 } -- 1.3.6.1.4.1.9839.1000.100 trapV1-100 NOTIFICATION-TYPE OBJECTS { al18-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 100 } -- 1.3.6.1.4.1.9839.1000.101 trapV1-101 NOTIFICATION-TYPE OBJECTS { al19-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 101 } -- 1.3.6.1.4.1.9839.1000.102 trapV1-102 NOTIFICATION-TYPE OBJECTS { al20-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 102 } -- 1.3.6.1.4.1.9839.1000.103 trapV1-103 NOTIFICATION-TYPE OBJECTS { al21-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 103 } -- 1.3.6.1.4.1.9839.1000.104 trapV1-104 NOTIFICATION-TYPE OBJECTS { al22-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 104 } -- 1.3.6.1.4.1.9839.1000.105 trapV1-105 NOTIFICATION-TYPE OBJECTS { al23-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 105 } -- 1.3.6.1.4.1.9839.1000.106 trapV1-106 NOTIFICATION-TYPE OBJECTS { al24-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 106 } -- 1.3.6.1.4.1.9839.1000.107 trapV1-107 NOTIFICATION-TYPE OBJECTS { al25-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 107 } -- 1.3.6.1.4.1.9839.1000.108 trapV1-108 NOTIFICATION-TYPE OBJECTS { al26-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 108 } -- 1.3.6.1.4.1.9839.1000.109 trapV1-109 NOTIFICATION-TYPE OBJECTS { al27-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 109 } -- 1.3.6.1.4.1.9839.1000.110 trapV1-110 NOTIFICATION-TYPE OBJECTS { al28-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 110 } -- 1.3.6.1.4.1.9839.1000.111 trapV1-111 NOTIFICATION-TYPE OBJECTS { al29-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 111 } -- 1.3.6.1.4.1.9839.1000.112 trapV1-112 NOTIFICATION-TYPE OBJECTS { al98-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 112 } -- 1.3.6.1.4.1.9839.1000.113 trapV1-113 NOTIFICATION-TYPE OBJECTS { al99-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 113 } -- 1.3.6.1.4.1.9839.1000.114 trapV1-114 NOTIFICATION-TYPE OBJECTS { alSafe101-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 114 } -- 1.3.6.1.4.1.9839.1000.115 trapV1-115 NOTIFICATION-TYPE OBJECTS { alSafe102-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 115 } -- 1.3.6.1.4.1.9839.1000.116 trapV1-116 NOTIFICATION-TYPE OBJECTS { alSafe103-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 116 } -- 1.3.6.1.4.1.9839.1000.117 trapV1-117 NOTIFICATION-TYPE OBJECTS { alSafe104-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 117 } -- 1.3.6.1.4.1.9839.1000.118 trapV1-118 NOTIFICATION-TYPE OBJECTS { alSafe105-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 118 } -- 1.3.6.1.4.1.9839.1000.119 trapV1-119 NOTIFICATION-TYPE OBJECTS { alSafe106-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 119 } -- 1.3.6.1.4.1.9839.1000.120 trapV1-120 NOTIFICATION-TYPE OBJECTS { alSafe107-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 120 } -- 1.3.6.1.4.1.9839.1000.121 trapV1-121 NOTIFICATION-TYPE OBJECTS { alSafe108-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 121 } -- 1.3.6.1.4.1.9839.1000.122 trapV1-122 NOTIFICATION-TYPE OBJECTS { alSafe109-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 122 } -- 1.3.6.1.4.1.9839.1000.123 trapV1-123 NOTIFICATION-TYPE OBJECTS { alSafe110-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 123 } -- 1.3.6.1.4.1.9839.1000.124 trapV1-124 NOTIFICATION-TYPE OBJECTS { alSafe111-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 124 } -- 1.3.6.1.4.1.9839.1000.125 trapV1-125 NOTIFICATION-TYPE OBJECTS { alSafe112-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 125 } -- 1.3.6.1.4.1.9839.1000.126 trapV1-126 NOTIFICATION-TYPE OBJECTS { alSafe113-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 126 } -- 1.3.6.1.4.1.9839.1000.127 trapV1-127 NOTIFICATION-TYPE OBJECTS { alSafe114-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 127 } -- 1.3.6.1.4.1.9839.1000.128 trapV1-128 NOTIFICATION-TYPE OBJECTS { alSafe115-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 128 } -- 1.3.6.1.4.1.9839.1000.129 trapV1-129 NOTIFICATION-TYPE OBJECTS { alSafe116-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 129 } -- 1.3.6.1.4.1.9839.1000.130 trapV1-130 NOTIFICATION-TYPE OBJECTS { alSafe201-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 130 } -- 1.3.6.1.4.1.9839.1000.131 trapV1-131 NOTIFICATION-TYPE OBJECTS { alSafe202-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 131 } -- 1.3.6.1.4.1.9839.1000.132 trapV1-132 NOTIFICATION-TYPE OBJECTS { alSafe203-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 132 } -- 1.3.6.1.4.1.9839.1000.133 trapV1-133 NOTIFICATION-TYPE OBJECTS { alSafe204-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 133 } -- 1.3.6.1.4.1.9839.1000.134 trapV1-134 NOTIFICATION-TYPE OBJECTS { alSafe205-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 134 } -- 1.3.6.1.4.1.9839.1000.135 trapV1-135 NOTIFICATION-TYPE OBJECTS { alSafe206-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 135 } -- 1.3.6.1.4.1.9839.1000.136 trapV1-136 NOTIFICATION-TYPE OBJECTS { alSafe207-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 136 } -- 1.3.6.1.4.1.9839.1000.137 trapV1-137 NOTIFICATION-TYPE OBJECTS { alSafe208-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 137 } -- 1.3.6.1.4.1.9839.1000.138 trapV1-138 NOTIFICATION-TYPE OBJECTS { alSafe209-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 138 } -- 1.3.6.1.4.1.9839.1000.139 trapV1-139 NOTIFICATION-TYPE OBJECTS { alSafe210-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 139 } -- 1.3.6.1.4.1.9839.1000.140 trapV1-140 NOTIFICATION-TYPE OBJECTS { alSafe211-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 140 } -- 1.3.6.1.4.1.9839.1000.141 trapV1-141 NOTIFICATION-TYPE OBJECTS { alSafe212-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 141 } -- 1.3.6.1.4.1.9839.1000.142 trapV1-142 NOTIFICATION-TYPE OBJECTS { alSafe213-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 142 } -- 1.3.6.1.4.1.9839.1000.143 trapV1-143 NOTIFICATION-TYPE OBJECTS { alSafe214-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 143 } -- 1.3.6.1.4.1.9839.1000.144 trapV1-144 NOTIFICATION-TYPE OBJECTS { alSafe215-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 144 } -- 1.3.6.1.4.1.9839.1000.145 trapV1-145 NOTIFICATION-TYPE OBJECTS { alSafe216-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 145 } -- 1.3.6.1.4.1.9839.1000.146 trapV1-146 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 146 } -- 1.3.6.1.4.1.9839.1000.147 trapV1-147 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 147 } -- 1.3.6.1.4.1.9839.1000.148 trapV1-148 NOTIFICATION-TYPE OBJECTS { al-LOP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 148 } -- 1.3.6.1.4.1.9839.1000.149 trapV1-149 NOTIFICATION-TYPE OBJECTS { al-MOP-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 149 } -- 1.3.6.1.4.1.9839.1000.150 trapV1-150 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 150 } -- 1.3.6.1.4.1.9839.1000.151 trapV1-151 NOTIFICATION-TYPE OBJECTS { al-EEV-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 151 } -- 1.3.6.1.4.1.9839.1000.152 trapV1-152 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 152 } -- 1.3.6.1.4.1.9839.1000.153 trapV1-153 NOTIFICATION-TYPE OBJECTS { al-OutEnv-BLDC1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 153 } -- 1.3.6.1.4.1.9839.1000.154 trapV1-154 NOTIFICATION-TYPE OBJECTS { al-ComprOff-BLDC1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 154 } -- 1.3.6.1.4.1.9839.1000.155 trapV1-155 NOTIFICATION-TYPE OBJECTS { aL-DisStartDpState-BLDC1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 155 } -- 1.3.6.1.4.1.9839.1000.156 trapV1-156 NOTIFICATION-TYPE OBJECTS { al-HiTempCond-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 156 } -- 1.3.6.1.4.1.9839.1000.157 trapV1-157 NOTIFICATION-TYPE OBJECTS { al-SelfTuning-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 157 } -- 1.3.6.1.4.1.9839.1000.158 trapV1-158 NOTIFICATION-TYPE OBJECTS { al-TempDelta-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 158 } -- 1.3.6.1.4.1.9839.1000.159 trapV1-159 NOTIFICATION-TYPE OBJECTS { al-P-Delta-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 159 } -- 1.3.6.1.4.1.9839.1000.160 trapV1-160 NOTIFICATION-TYPE OBJECTS { al-RangeError-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 160 } -- 1.3.6.1.4.1.9839.1000.161 trapV1-161 NOTIFICATION-TYPE OBJECTS { al-ServicePosit-perc-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 161 } -- 1.3.6.1.4.1.9839.1000.162 trapV1-162 NOTIFICATION-TYPE OBJECTS { al-ValveID-1-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 162 } -- 1.3.6.1.4.1.9839.1000.163 trapV1-163 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-Active } STATUS current DESCRIPTION "Reserved" ::= { snmpTraps 163 } -- 1.3.6.1.4.1.9839.1000.164 trapV1-164 NOTIFICATION-TYPE OBJECTS { al-retain-M01-Active } STATUS current DESCRIPTION "HVAC-1-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 164 } -- 1.3.6.1.4.1.9839.1000.165 trapV1-165 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M01-Active } STATUS current DESCRIPTION "HVAC-1-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 165 } -- 1.3.6.1.4.1.9839.1000.166 trapV1-166 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M01-Active } STATUS current DESCRIPTION "HVAC-1-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 166 } -- 1.3.6.1.4.1.9839.1000.167 trapV1-167 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M01-Active } STATUS current DESCRIPTION "HVAC-1-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 167 } -- 1.3.6.1.4.1.9839.1000.168 trapV1-168 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M01-Active } STATUS current DESCRIPTION "HVAC-1-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 168 } -- 1.3.6.1.4.1.9839.1000.169 trapV1-169 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M01-Active } STATUS current DESCRIPTION "HVAC-1-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 169 } -- 1.3.6.1.4.1.9839.1000.170 trapV1-170 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M01-Active } STATUS current DESCRIPTION "HVAC-1-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 170 } -- 1.3.6.1.4.1.9839.1000.171 trapV1-171 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M01-Active } STATUS current DESCRIPTION "HVAC-1-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 171 } -- 1.3.6.1.4.1.9839.1000.172 trapV1-172 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M01-Active } STATUS current DESCRIPTION "HVAC-1-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 172 } -- 1.3.6.1.4.1.9839.1000.173 trapV1-173 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M01-Active } STATUS current DESCRIPTION "HVAC-1-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 173 } -- 1.3.6.1.4.1.9839.1000.174 trapV1-174 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M01-Active } STATUS current DESCRIPTION "HVAC-1-Humidity-Alarm-Alarm-status" ::= { snmpTraps 174 } -- 1.3.6.1.4.1.9839.1000.175 trapV1-175 NOTIFICATION-TYPE OBJECTS { al-Smoke-M01-Active } STATUS current DESCRIPTION "HVAC-1-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 175 } -- 1.3.6.1.4.1.9839.1000.176 trapV1-176 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M01-Active } STATUS current DESCRIPTION "HVAC-1-Inverter-Overload-Alarm-status" ::= { snmpTraps 176 } -- 1.3.6.1.4.1.9839.1000.177 trapV1-177 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M01-Active } STATUS current DESCRIPTION "HVAC-1-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 177 } -- 1.3.6.1.4.1.9839.1000.178 trapV1-178 NOTIFICATION-TYPE OBJECTS { al-HiP-M01-Active } STATUS current DESCRIPTION "HVAC-1-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 178 } -- 1.3.6.1.4.1.9839.1000.179 trapV1-179 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M01-Active } STATUS current DESCRIPTION "HVAC-1-DC-Failover-Active-Alarm-status" ::= { snmpTraps 179 } -- 1.3.6.1.4.1.9839.1000.180 trapV1-180 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M01-Active } STATUS current DESCRIPTION "HVAC-1-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 180 } -- 1.3.6.1.4.1.9839.1000.181 trapV1-181 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M01-Active } STATUS current DESCRIPTION "HVAC-1-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 181 } -- 1.3.6.1.4.1.9839.1000.182 trapV1-182 NOTIFICATION-TYPE OBJECTS { al-LowP-M01-Active } STATUS current DESCRIPTION "HVAC-1-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 182 } -- 1.3.6.1.4.1.9839.1000.183 trapV1-183 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M01-Active } STATUS current DESCRIPTION "HVAC-1-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 183 } -- 1.3.6.1.4.1.9839.1000.184 trapV1-184 NOTIFICATION-TYPE OBJECTS { al-Filt-M01-Active } STATUS current DESCRIPTION "HVAC-1-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 184 } -- 1.3.6.1.4.1.9839.1000.185 trapV1-185 NOTIFICATION-TYPE OBJECTS { al-Dust-M01-Active } STATUS current DESCRIPTION "HVAC-1-AFPD-Triggered-Alarm-status" ::= { snmpTraps 185 } -- 1.3.6.1.4.1.9839.1000.186 trapV1-186 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M01-Active } STATUS current DESCRIPTION "HVAC-1-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 186 } -- 1.3.6.1.4.1.9839.1000.187 trapV1-187 NOTIFICATION-TYPE OBJECTS { al-Damper-M01-Active } STATUS current DESCRIPTION "HVAC-1-Damper-Alarm-Alarm-status" ::= { snmpTraps 187 } -- 1.3.6.1.4.1.9839.1000.188 trapV1-188 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M01-Active } STATUS current DESCRIPTION "HVAC-1-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 188 } -- 1.3.6.1.4.1.9839.1000.189 trapV1-189 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M01-Active } STATUS current DESCRIPTION "HVAC-1-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 189 } -- 1.3.6.1.4.1.9839.1000.190 trapV1-190 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M01-Active } STATUS current DESCRIPTION "HVAC-1-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 190 } -- 1.3.6.1.4.1.9839.1000.191 trapV1-191 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M01-Active } STATUS current DESCRIPTION "HVAC-1-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 191 } -- 1.3.6.1.4.1.9839.1000.192 trapV1-192 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M01-Active } STATUS current DESCRIPTION "HVAC-1-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 192 } -- 1.3.6.1.4.1.9839.1000.193 trapV1-193 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M01-Active } STATUS current DESCRIPTION "HVAC-1-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 193 } -- 1.3.6.1.4.1.9839.1000.194 trapV1-194 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M01-Active } STATUS current DESCRIPTION "HVAC-1-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 194 } -- 1.3.6.1.4.1.9839.1000.195 trapV1-195 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M01-Active } STATUS current DESCRIPTION "HVAC-1-EEV-Alarm-Alarm-status" ::= { snmpTraps 195 } -- 1.3.6.1.4.1.9839.1000.196 trapV1-196 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M01-Active } STATUS current DESCRIPTION "HVAC-1-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 196 } -- 1.3.6.1.4.1.9839.1000.197 trapV1-197 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M01-Active } STATUS current DESCRIPTION "HVAC-1-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 197 } -- 1.3.6.1.4.1.9839.1000.198 trapV1-198 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M01-Active } STATUS current DESCRIPTION "HVAC-1-Inverter-Offline-Alarm-status" ::= { snmpTraps 198 } -- 1.3.6.1.4.1.9839.1000.199 trapV1-199 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M01-Active } STATUS current DESCRIPTION "HVAC-1-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 199 } -- 1.3.6.1.4.1.9839.1000.200 trapV1-200 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M01-Active } STATUS current DESCRIPTION "HVAC-1-BLDC-Alarm-Alarm-status" ::= { snmpTraps 200 } -- 1.3.6.1.4.1.9839.1000.201 trapV1-201 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M01-Active } STATUS current DESCRIPTION "HVAC-1-Dirty-Condenser-Alarm-status" ::= { snmpTraps 201 } -- 1.3.6.1.4.1.9839.1000.202 trapV1-202 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M01-Active } STATUS current DESCRIPTION "HVAC-1-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 202 } -- 1.3.6.1.4.1.9839.1000.203 trapV1-203 NOTIFICATION-TYPE OBJECTS { al-retain-M02-Active } STATUS current DESCRIPTION "HVAC-2-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 203 } -- 1.3.6.1.4.1.9839.1000.204 trapV1-204 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M02-Active } STATUS current DESCRIPTION "HVAC-2-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 204 } -- 1.3.6.1.4.1.9839.1000.205 trapV1-205 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M02-Active } STATUS current DESCRIPTION "HVAC-2-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 205 } -- 1.3.6.1.4.1.9839.1000.206 trapV1-206 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M02-Active } STATUS current DESCRIPTION "HVAC-2-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 206 } -- 1.3.6.1.4.1.9839.1000.207 trapV1-207 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M02-Active } STATUS current DESCRIPTION "HVAC-2-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 207 } -- 1.3.6.1.4.1.9839.1000.208 trapV1-208 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M02-Active } STATUS current DESCRIPTION "HVAC-2-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 208 } -- 1.3.6.1.4.1.9839.1000.209 trapV1-209 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M02-Active } STATUS current DESCRIPTION "HVAC-2-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 209 } -- 1.3.6.1.4.1.9839.1000.210 trapV1-210 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M02-Active } STATUS current DESCRIPTION "HVAC-2-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 210 } -- 1.3.6.1.4.1.9839.1000.211 trapV1-211 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M02-Active } STATUS current DESCRIPTION "HVAC-2-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 211 } -- 1.3.6.1.4.1.9839.1000.212 trapV1-212 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M02-Active } STATUS current DESCRIPTION "HVAC-2-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 212 } -- 1.3.6.1.4.1.9839.1000.213 trapV1-213 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M02-Active } STATUS current DESCRIPTION "HVAC-2-Humidity-Alarm-Alarm-status" ::= { snmpTraps 213 } -- 1.3.6.1.4.1.9839.1000.214 trapV1-214 NOTIFICATION-TYPE OBJECTS { al-Smoke-M02-Active } STATUS current DESCRIPTION "HVAC-2-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 214 } -- 1.3.6.1.4.1.9839.1000.215 trapV1-215 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M02-Active } STATUS current DESCRIPTION "HVAC-2-Inverter-Overload-Alarm-status" ::= { snmpTraps 215 } -- 1.3.6.1.4.1.9839.1000.216 trapV1-216 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M02-Active } STATUS current DESCRIPTION "HVAC-2-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 216 } -- 1.3.6.1.4.1.9839.1000.217 trapV1-217 NOTIFICATION-TYPE OBJECTS { al-HiP-M02-Active } STATUS current DESCRIPTION "HVAC-2-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 217 } -- 1.3.6.1.4.1.9839.1000.218 trapV1-218 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M02-Active } STATUS current DESCRIPTION "HVAC-2-DC-Failover-Active-Alarm-status" ::= { snmpTraps 218 } -- 1.3.6.1.4.1.9839.1000.219 trapV1-219 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M02-Active } STATUS current DESCRIPTION "HVAC-2-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 219 } -- 1.3.6.1.4.1.9839.1000.220 trapV1-220 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M02-Active } STATUS current DESCRIPTION "HVAC-2-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 220 } -- 1.3.6.1.4.1.9839.1000.221 trapV1-221 NOTIFICATION-TYPE OBJECTS { al-LowP-M02-Active } STATUS current DESCRIPTION "HVAC-2-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 221 } -- 1.3.6.1.4.1.9839.1000.222 trapV1-222 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M02-Active } STATUS current DESCRIPTION "HVAC-2-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 222 } -- 1.3.6.1.4.1.9839.1000.223 trapV1-223 NOTIFICATION-TYPE OBJECTS { al-Filt-M02-Active } STATUS current DESCRIPTION "HVAC-2-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 223 } -- 1.3.6.1.4.1.9839.1000.224 trapV1-224 NOTIFICATION-TYPE OBJECTS { al-Dust-M02-Active } STATUS current DESCRIPTION "HVAC-2-AFPD-Triggered-Alarm-status" ::= { snmpTraps 224 } -- 1.3.6.1.4.1.9839.1000.225 trapV1-225 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M02-Active } STATUS current DESCRIPTION "HVAC-2-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 225 } -- 1.3.6.1.4.1.9839.1000.226 trapV1-226 NOTIFICATION-TYPE OBJECTS { al-Damper-M02-Active } STATUS current DESCRIPTION "HVAC-2-Damper-Alarm-Alarm-status" ::= { snmpTraps 226 } -- 1.3.6.1.4.1.9839.1000.227 trapV1-227 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M02-Active } STATUS current DESCRIPTION "HVAC-2-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 227 } -- 1.3.6.1.4.1.9839.1000.228 trapV1-228 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M02-Active } STATUS current DESCRIPTION "HVAC-2-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 228 } -- 1.3.6.1.4.1.9839.1000.229 trapV1-229 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M02-Active } STATUS current DESCRIPTION "HVAC-2-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 229 } -- 1.3.6.1.4.1.9839.1000.230 trapV1-230 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M02-Active } STATUS current DESCRIPTION "HVAC-2-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 230 } -- 1.3.6.1.4.1.9839.1000.231 trapV1-231 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M02-Active } STATUS current DESCRIPTION "HVAC-2-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 231 } -- 1.3.6.1.4.1.9839.1000.232 trapV1-232 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M02-Active } STATUS current DESCRIPTION "HVAC-2-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 232 } -- 1.3.6.1.4.1.9839.1000.233 trapV1-233 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M02-Active } STATUS current DESCRIPTION "HVAC-2-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 233 } -- 1.3.6.1.4.1.9839.1000.234 trapV1-234 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M02-Active } STATUS current DESCRIPTION "HVAC-2-EEV-Alarm-Alarm-status" ::= { snmpTraps 234 } -- 1.3.6.1.4.1.9839.1000.235 trapV1-235 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M02-Active } STATUS current DESCRIPTION "HVAC-2-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 235 } -- 1.3.6.1.4.1.9839.1000.236 trapV1-236 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M02-Active } STATUS current DESCRIPTION "HVAC-2-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 236 } -- 1.3.6.1.4.1.9839.1000.237 trapV1-237 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M02-Active } STATUS current DESCRIPTION "HVAC-2-Inverter-Offline-Alarm-status" ::= { snmpTraps 237 } -- 1.3.6.1.4.1.9839.1000.238 trapV1-238 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M02-Active } STATUS current DESCRIPTION "HVAC-2-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 238 } -- 1.3.6.1.4.1.9839.1000.239 trapV1-239 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M02-Active } STATUS current DESCRIPTION "HVAC-2-BLDC-Alarm-Alarm-status" ::= { snmpTraps 239 } -- 1.3.6.1.4.1.9839.1000.240 trapV1-240 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M02-Active } STATUS current DESCRIPTION "HVAC-2-Dirty-Condenser-Alarm-status" ::= { snmpTraps 240 } -- 1.3.6.1.4.1.9839.1000.241 trapV1-241 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M02-Active } STATUS current DESCRIPTION "HVAC-2-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 241 } -- 1.3.6.1.4.1.9839.1000.242 trapV1-242 NOTIFICATION-TYPE OBJECTS { al-retain-M03-Active } STATUS current DESCRIPTION "HVAC-3-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 242 } -- 1.3.6.1.4.1.9839.1000.243 trapV1-243 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M03-Active } STATUS current DESCRIPTION "HVAC-3-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 243 } -- 1.3.6.1.4.1.9839.1000.244 trapV1-244 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M03-Active } STATUS current DESCRIPTION "HVAC-3-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 244 } -- 1.3.6.1.4.1.9839.1000.245 trapV1-245 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M03-Active } STATUS current DESCRIPTION "HVAC-3-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 245 } -- 1.3.6.1.4.1.9839.1000.246 trapV1-246 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M03-Active } STATUS current DESCRIPTION "HVAC-3-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 246 } -- 1.3.6.1.4.1.9839.1000.247 trapV1-247 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M03-Active } STATUS current DESCRIPTION "HVAC-3-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 247 } -- 1.3.6.1.4.1.9839.1000.248 trapV1-248 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M03-Active } STATUS current DESCRIPTION "HVAC-3-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 248 } -- 1.3.6.1.4.1.9839.1000.249 trapV1-249 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M03-Active } STATUS current DESCRIPTION "HVAC-3-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 249 } -- 1.3.6.1.4.1.9839.1000.250 trapV1-250 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M03-Active } STATUS current DESCRIPTION "HVAC-3-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 250 } -- 1.3.6.1.4.1.9839.1000.251 trapV1-251 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M03-Active } STATUS current DESCRIPTION "HVAC-3-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 251 } -- 1.3.6.1.4.1.9839.1000.252 trapV1-252 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M03-Active } STATUS current DESCRIPTION "HVAC-3-Humidity-Alarm-Alarm-status" ::= { snmpTraps 252 } -- 1.3.6.1.4.1.9839.1000.253 trapV1-253 NOTIFICATION-TYPE OBJECTS { al-Smoke-M03-Active } STATUS current DESCRIPTION "HVAC-3-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 253 } -- 1.3.6.1.4.1.9839.1000.254 trapV1-254 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M03-Active } STATUS current DESCRIPTION "HVAC-3-Inverter-Overload-Alarm-status" ::= { snmpTraps 254 } -- 1.3.6.1.4.1.9839.1000.255 trapV1-255 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M03-Active } STATUS current DESCRIPTION "HVAC-3-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 255 } -- 1.3.6.1.4.1.9839.1000.256 trapV1-256 NOTIFICATION-TYPE OBJECTS { al-HiP-M03-Active } STATUS current DESCRIPTION "HVAC-3-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 256 } -- 1.3.6.1.4.1.9839.1000.257 trapV1-257 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M03-Active } STATUS current DESCRIPTION "HVAC-3-DC-Failover-Active-Alarm-status" ::= { snmpTraps 257 } -- 1.3.6.1.4.1.9839.1000.258 trapV1-258 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M03-Active } STATUS current DESCRIPTION "HVAC-3-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 258 } -- 1.3.6.1.4.1.9839.1000.259 trapV1-259 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M03-Active } STATUS current DESCRIPTION "HVAC-3-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 259 } -- 1.3.6.1.4.1.9839.1000.260 trapV1-260 NOTIFICATION-TYPE OBJECTS { al-LowP-M03-Active } STATUS current DESCRIPTION "HVAC-3-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 260 } -- 1.3.6.1.4.1.9839.1000.261 trapV1-261 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M03-Active } STATUS current DESCRIPTION "HVAC-3-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 261 } -- 1.3.6.1.4.1.9839.1000.262 trapV1-262 NOTIFICATION-TYPE OBJECTS { al-Filt-M03-Active } STATUS current DESCRIPTION "HVAC-3-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 262 } -- 1.3.6.1.4.1.9839.1000.263 trapV1-263 NOTIFICATION-TYPE OBJECTS { al-Dust-M03-Active } STATUS current DESCRIPTION "HVAC-3-AFPD-Triggered-Alarm-status" ::= { snmpTraps 263 } -- 1.3.6.1.4.1.9839.1000.264 trapV1-264 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M03-Active } STATUS current DESCRIPTION "HVAC-3-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 264 } -- 1.3.6.1.4.1.9839.1000.265 trapV1-265 NOTIFICATION-TYPE OBJECTS { al-Damper-M03-Active } STATUS current DESCRIPTION "HVAC-3-Damper-Alarm-Alarm-status" ::= { snmpTraps 265 } -- 1.3.6.1.4.1.9839.1000.266 trapV1-266 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M03-Active } STATUS current DESCRIPTION "HVAC-3-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 266 } -- 1.3.6.1.4.1.9839.1000.267 trapV1-267 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M03-Active } STATUS current DESCRIPTION "HVAC-3-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 267 } -- 1.3.6.1.4.1.9839.1000.268 trapV1-268 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M03-Active } STATUS current DESCRIPTION "HVAC-3-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 268 } -- 1.3.6.1.4.1.9839.1000.269 trapV1-269 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M03-Active } STATUS current DESCRIPTION "HVAC-3-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 269 } -- 1.3.6.1.4.1.9839.1000.270 trapV1-270 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M03-Active } STATUS current DESCRIPTION "HVAC-3-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 270 } -- 1.3.6.1.4.1.9839.1000.271 trapV1-271 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M03-Active } STATUS current DESCRIPTION "HVAC-3-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 271 } -- 1.3.6.1.4.1.9839.1000.272 trapV1-272 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M03-Active } STATUS current DESCRIPTION "HVAC-3-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 272 } -- 1.3.6.1.4.1.9839.1000.273 trapV1-273 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M03-Active } STATUS current DESCRIPTION "HVAC-3-EEV-Alarm-Alarm-status" ::= { snmpTraps 273 } -- 1.3.6.1.4.1.9839.1000.274 trapV1-274 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M03-Active } STATUS current DESCRIPTION "HVAC-3-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 274 } -- 1.3.6.1.4.1.9839.1000.275 trapV1-275 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M03-Active } STATUS current DESCRIPTION "HVAC-3-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 275 } -- 1.3.6.1.4.1.9839.1000.276 trapV1-276 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M03-Active } STATUS current DESCRIPTION "HVAC-3-Inverter-Offline-Alarm-status" ::= { snmpTraps 276 } -- 1.3.6.1.4.1.9839.1000.277 trapV1-277 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M03-Active } STATUS current DESCRIPTION "HVAC-3-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 277 } -- 1.3.6.1.4.1.9839.1000.278 trapV1-278 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M03-Active } STATUS current DESCRIPTION "HVAC-3-BLDC-Alarm-Alarm-status" ::= { snmpTraps 278 } -- 1.3.6.1.4.1.9839.1000.279 trapV1-279 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M03-Active } STATUS current DESCRIPTION "HVAC-3-Dirty-Condenser-Alarm-status" ::= { snmpTraps 279 } -- 1.3.6.1.4.1.9839.1000.280 trapV1-280 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M03-Active } STATUS current DESCRIPTION "HVAC-3-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 280 } -- 1.3.6.1.4.1.9839.1000.281 trapV1-281 NOTIFICATION-TYPE OBJECTS { al-retain-M04-Active } STATUS current DESCRIPTION "HVAC-4-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 281 } -- 1.3.6.1.4.1.9839.1000.282 trapV1-282 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M04-Active } STATUS current DESCRIPTION "HVAC-4-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 282 } -- 1.3.6.1.4.1.9839.1000.283 trapV1-283 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M04-Active } STATUS current DESCRIPTION "HVAC-4-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 283 } -- 1.3.6.1.4.1.9839.1000.284 trapV1-284 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M04-Active } STATUS current DESCRIPTION "HVAC-4-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 284 } -- 1.3.6.1.4.1.9839.1000.285 trapV1-285 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M04-Active } STATUS current DESCRIPTION "HVAC-4-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 285 } -- 1.3.6.1.4.1.9839.1000.286 trapV1-286 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M04-Active } STATUS current DESCRIPTION "HVAC-4-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 286 } -- 1.3.6.1.4.1.9839.1000.287 trapV1-287 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M04-Active } STATUS current DESCRIPTION "HVAC-4-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 287 } -- 1.3.6.1.4.1.9839.1000.288 trapV1-288 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M04-Active } STATUS current DESCRIPTION "HVAC-4-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 288 } -- 1.3.6.1.4.1.9839.1000.289 trapV1-289 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M04-Active } STATUS current DESCRIPTION "HVAC-4-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 289 } -- 1.3.6.1.4.1.9839.1000.290 trapV1-290 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M04-Active } STATUS current DESCRIPTION "HVAC-4-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 290 } -- 1.3.6.1.4.1.9839.1000.291 trapV1-291 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M04-Active } STATUS current DESCRIPTION "HVAC-4-Humidity-Alarm-Alarm-status" ::= { snmpTraps 291 } -- 1.3.6.1.4.1.9839.1000.292 trapV1-292 NOTIFICATION-TYPE OBJECTS { al-Smoke-M04-Active } STATUS current DESCRIPTION "HVAC-4-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 292 } -- 1.3.6.1.4.1.9839.1000.293 trapV1-293 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M04-Active } STATUS current DESCRIPTION "HVAC-4-Inverter-Overload-Alarm-status" ::= { snmpTraps 293 } -- 1.3.6.1.4.1.9839.1000.294 trapV1-294 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M04-Active } STATUS current DESCRIPTION "HVAC-4-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 294 } -- 1.3.6.1.4.1.9839.1000.295 trapV1-295 NOTIFICATION-TYPE OBJECTS { al-HiP-M04-Active } STATUS current DESCRIPTION "HVAC-4-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 295 } -- 1.3.6.1.4.1.9839.1000.296 trapV1-296 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M04-Active } STATUS current DESCRIPTION "HVAC-4-DC-Failover-Active-Alarm-status" ::= { snmpTraps 296 } -- 1.3.6.1.4.1.9839.1000.297 trapV1-297 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M04-Active } STATUS current DESCRIPTION "HVAC-4-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 297 } -- 1.3.6.1.4.1.9839.1000.298 trapV1-298 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M04-Active } STATUS current DESCRIPTION "HVAC-4-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 298 } -- 1.3.6.1.4.1.9839.1000.299 trapV1-299 NOTIFICATION-TYPE OBJECTS { al-LowP-M04-Active } STATUS current DESCRIPTION "HVAC-4-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 299 } -- 1.3.6.1.4.1.9839.1000.300 trapV1-300 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M04-Active } STATUS current DESCRIPTION "HVAC-4-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 300 } -- 1.3.6.1.4.1.9839.1000.301 trapV1-301 NOTIFICATION-TYPE OBJECTS { al-Filt-M04-Active } STATUS current DESCRIPTION "HVAC-4-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 301 } -- 1.3.6.1.4.1.9839.1000.302 trapV1-302 NOTIFICATION-TYPE OBJECTS { al-Dust-M04-Active } STATUS current DESCRIPTION "HVAC-4-AFPD-Triggered-Alarm-status" ::= { snmpTraps 302 } -- 1.3.6.1.4.1.9839.1000.303 trapV1-303 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M04-Active } STATUS current DESCRIPTION "HVAC-4-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 303 } -- 1.3.6.1.4.1.9839.1000.304 trapV1-304 NOTIFICATION-TYPE OBJECTS { al-Damper-M04-Active } STATUS current DESCRIPTION "HVAC-4-Damper-Alarm-Alarm-status" ::= { snmpTraps 304 } -- 1.3.6.1.4.1.9839.1000.305 trapV1-305 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M04-Active } STATUS current DESCRIPTION "HVAC-4-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 305 } -- 1.3.6.1.4.1.9839.1000.306 trapV1-306 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M04-Active } STATUS current DESCRIPTION "HVAC-4-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 306 } -- 1.3.6.1.4.1.9839.1000.307 trapV1-307 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M04-Active } STATUS current DESCRIPTION "HVAC-4-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 307 } -- 1.3.6.1.4.1.9839.1000.308 trapV1-308 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M04-Active } STATUS current DESCRIPTION "HVAC-4-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 308 } -- 1.3.6.1.4.1.9839.1000.309 trapV1-309 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M04-Active } STATUS current DESCRIPTION "HVAC-4-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 309 } -- 1.3.6.1.4.1.9839.1000.310 trapV1-310 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M04-Active } STATUS current DESCRIPTION "HVAC-4-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 310 } -- 1.3.6.1.4.1.9839.1000.311 trapV1-311 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M04-Active } STATUS current DESCRIPTION "HVAC-4-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 311 } -- 1.3.6.1.4.1.9839.1000.312 trapV1-312 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M04-Active } STATUS current DESCRIPTION "HVAC-4-EEV-Alarm-Alarm-status" ::= { snmpTraps 312 } -- 1.3.6.1.4.1.9839.1000.313 trapV1-313 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M04-Active } STATUS current DESCRIPTION "HVAC-4-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 313 } -- 1.3.6.1.4.1.9839.1000.314 trapV1-314 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M04-Active } STATUS current DESCRIPTION "HVAC-4-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 314 } -- 1.3.6.1.4.1.9839.1000.315 trapV1-315 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M04-Active } STATUS current DESCRIPTION "HVAC-4-Inverter-Offline-Alarm-status" ::= { snmpTraps 315 } -- 1.3.6.1.4.1.9839.1000.316 trapV1-316 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M04-Active } STATUS current DESCRIPTION "HVAC-4-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 316 } -- 1.3.6.1.4.1.9839.1000.317 trapV1-317 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M04-Active } STATUS current DESCRIPTION "HVAC-4-BLDC-Alarm-Alarm-status" ::= { snmpTraps 317 } -- 1.3.6.1.4.1.9839.1000.318 trapV1-318 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M04-Active } STATUS current DESCRIPTION "HVAC-4-Dirty-Condenser-Alarm-status" ::= { snmpTraps 318 } -- 1.3.6.1.4.1.9839.1000.319 trapV1-319 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M04-Active } STATUS current DESCRIPTION "HVAC-4-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 319 } -- 1.3.6.1.4.1.9839.1000.320 trapV1-320 NOTIFICATION-TYPE OBJECTS { al-retain-M05-Active } STATUS current DESCRIPTION "HVAC-5-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 320 } -- 1.3.6.1.4.1.9839.1000.321 trapV1-321 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M05-Active } STATUS current DESCRIPTION "HVAC-5-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 321 } -- 1.3.6.1.4.1.9839.1000.322 trapV1-322 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M05-Active } STATUS current DESCRIPTION "HVAC-5-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 322 } -- 1.3.6.1.4.1.9839.1000.323 trapV1-323 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M05-Active } STATUS current DESCRIPTION "HVAC-5-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 323 } -- 1.3.6.1.4.1.9839.1000.324 trapV1-324 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M05-Active } STATUS current DESCRIPTION "HVAC-5-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 324 } -- 1.3.6.1.4.1.9839.1000.325 trapV1-325 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M05-Active } STATUS current DESCRIPTION "HVAC-5-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 325 } -- 1.3.6.1.4.1.9839.1000.326 trapV1-326 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M05-Active } STATUS current DESCRIPTION "HVAC-5-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 326 } -- 1.3.6.1.4.1.9839.1000.327 trapV1-327 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M05-Active } STATUS current DESCRIPTION "HVAC-5-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 327 } -- 1.3.6.1.4.1.9839.1000.328 trapV1-328 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M05-Active } STATUS current DESCRIPTION "HVAC-5-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 328 } -- 1.3.6.1.4.1.9839.1000.329 trapV1-329 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M05-Active } STATUS current DESCRIPTION "HVAC-5-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 329 } -- 1.3.6.1.4.1.9839.1000.330 trapV1-330 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M05-Active } STATUS current DESCRIPTION "HVAC-5-Humidity-Alarm-Alarm-status" ::= { snmpTraps 330 } -- 1.3.6.1.4.1.9839.1000.331 trapV1-331 NOTIFICATION-TYPE OBJECTS { al-Smoke-M05-Active } STATUS current DESCRIPTION "HVAC-5-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 331 } -- 1.3.6.1.4.1.9839.1000.332 trapV1-332 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M05-Active } STATUS current DESCRIPTION "HVAC-5-Inverter-Overload-Alarm-status" ::= { snmpTraps 332 } -- 1.3.6.1.4.1.9839.1000.333 trapV1-333 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M05-Active } STATUS current DESCRIPTION "HVAC-5-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 333 } -- 1.3.6.1.4.1.9839.1000.334 trapV1-334 NOTIFICATION-TYPE OBJECTS { al-HiP-M05-Active } STATUS current DESCRIPTION "HVAC-5-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 334 } -- 1.3.6.1.4.1.9839.1000.335 trapV1-335 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M05-Active } STATUS current DESCRIPTION "HVAC-5-DC-Failover-Active-Alarm-status" ::= { snmpTraps 335 } -- 1.3.6.1.4.1.9839.1000.336 trapV1-336 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M05-Active } STATUS current DESCRIPTION "HVAC-5-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 336 } -- 1.3.6.1.4.1.9839.1000.337 trapV1-337 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M05-Active } STATUS current DESCRIPTION "HVAC-5-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 337 } -- 1.3.6.1.4.1.9839.1000.338 trapV1-338 NOTIFICATION-TYPE OBJECTS { al-LowP-M05-Active } STATUS current DESCRIPTION "HVAC-5-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 338 } -- 1.3.6.1.4.1.9839.1000.339 trapV1-339 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M05-Active } STATUS current DESCRIPTION "HVAC-5-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 339 } -- 1.3.6.1.4.1.9839.1000.340 trapV1-340 NOTIFICATION-TYPE OBJECTS { al-Filt-M05-Active } STATUS current DESCRIPTION "HVAC-5-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 340 } -- 1.3.6.1.4.1.9839.1000.341 trapV1-341 NOTIFICATION-TYPE OBJECTS { al-Dust-M05-Active } STATUS current DESCRIPTION "HVAC-5-AFPD-Triggered-Alarm-status" ::= { snmpTraps 341 } -- 1.3.6.1.4.1.9839.1000.342 trapV1-342 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M05-Active } STATUS current DESCRIPTION "HVAC-5-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 342 } -- 1.3.6.1.4.1.9839.1000.343 trapV1-343 NOTIFICATION-TYPE OBJECTS { al-Damper-M05-Active } STATUS current DESCRIPTION "HVAC-5-Damper-Alarm-Alarm-status" ::= { snmpTraps 343 } -- 1.3.6.1.4.1.9839.1000.344 trapV1-344 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M05-Active } STATUS current DESCRIPTION "HVAC-5-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 344 } -- 1.3.6.1.4.1.9839.1000.345 trapV1-345 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M05-Active } STATUS current DESCRIPTION "HVAC-5-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 345 } -- 1.3.6.1.4.1.9839.1000.346 trapV1-346 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M05-Active } STATUS current DESCRIPTION "HVAC-5-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 346 } -- 1.3.6.1.4.1.9839.1000.347 trapV1-347 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M05-Active } STATUS current DESCRIPTION "HVAC-5-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 347 } -- 1.3.6.1.4.1.9839.1000.348 trapV1-348 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M05-Active } STATUS current DESCRIPTION "HVAC-5-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 348 } -- 1.3.6.1.4.1.9839.1000.349 trapV1-349 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M05-Active } STATUS current DESCRIPTION "HVAC-5-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 349 } -- 1.3.6.1.4.1.9839.1000.350 trapV1-350 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M05-Active } STATUS current DESCRIPTION "HVAC-5-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 350 } -- 1.3.6.1.4.1.9839.1000.351 trapV1-351 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M05-Active } STATUS current DESCRIPTION "HVAC-5-EEV-Alarm-Alarm-status" ::= { snmpTraps 351 } -- 1.3.6.1.4.1.9839.1000.352 trapV1-352 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M05-Active } STATUS current DESCRIPTION "HVAC-5-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 352 } -- 1.3.6.1.4.1.9839.1000.353 trapV1-353 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M05-Active } STATUS current DESCRIPTION "HVAC-5-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 353 } -- 1.3.6.1.4.1.9839.1000.354 trapV1-354 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M05-Active } STATUS current DESCRIPTION "HVAC-5-Inverter-Offline-Alarm-status" ::= { snmpTraps 354 } -- 1.3.6.1.4.1.9839.1000.355 trapV1-355 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M05-Active } STATUS current DESCRIPTION "HVAC-5-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 355 } -- 1.3.6.1.4.1.9839.1000.356 trapV1-356 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M05-Active } STATUS current DESCRIPTION "HVAC-5-BLDC-Alarm-Alarm-status" ::= { snmpTraps 356 } -- 1.3.6.1.4.1.9839.1000.357 trapV1-357 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M05-Active } STATUS current DESCRIPTION "HVAC-5-Dirty-Condenser-Alarm-status" ::= { snmpTraps 357 } -- 1.3.6.1.4.1.9839.1000.358 trapV1-358 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M05-Active } STATUS current DESCRIPTION "HVAC-5-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 358 } -- 1.3.6.1.4.1.9839.1000.359 trapV1-359 NOTIFICATION-TYPE OBJECTS { al-retain-M06-Active } STATUS current DESCRIPTION "HVAC-6-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 359 } -- 1.3.6.1.4.1.9839.1000.360 trapV1-360 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M06-Active } STATUS current DESCRIPTION "HVAC-6-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 360 } -- 1.3.6.1.4.1.9839.1000.361 trapV1-361 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M06-Active } STATUS current DESCRIPTION "HVAC-6-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 361 } -- 1.3.6.1.4.1.9839.1000.362 trapV1-362 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M06-Active } STATUS current DESCRIPTION "HVAC-6-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 362 } -- 1.3.6.1.4.1.9839.1000.363 trapV1-363 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M06-Active } STATUS current DESCRIPTION "HVAC-6-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 363 } -- 1.3.6.1.4.1.9839.1000.364 trapV1-364 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M06-Active } STATUS current DESCRIPTION "HVAC-6-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 364 } -- 1.3.6.1.4.1.9839.1000.365 trapV1-365 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M06-Active } STATUS current DESCRIPTION "HVAC-6-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 365 } -- 1.3.6.1.4.1.9839.1000.366 trapV1-366 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M06-Active } STATUS current DESCRIPTION "HVAC-6-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 366 } -- 1.3.6.1.4.1.9839.1000.367 trapV1-367 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M06-Active } STATUS current DESCRIPTION "HVAC-6-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 367 } -- 1.3.6.1.4.1.9839.1000.368 trapV1-368 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M06-Active } STATUS current DESCRIPTION "HVAC-6-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 368 } -- 1.3.6.1.4.1.9839.1000.369 trapV1-369 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M06-Active } STATUS current DESCRIPTION "HVAC-6-Humidity-Alarm-Alarm-status" ::= { snmpTraps 369 } -- 1.3.6.1.4.1.9839.1000.370 trapV1-370 NOTIFICATION-TYPE OBJECTS { al-Smoke-M06-Active } STATUS current DESCRIPTION "HVAC-6-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 370 } -- 1.3.6.1.4.1.9839.1000.371 trapV1-371 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M06-Active } STATUS current DESCRIPTION "HVAC-6-Inverter-Overload-Alarm-status" ::= { snmpTraps 371 } -- 1.3.6.1.4.1.9839.1000.372 trapV1-372 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M06-Active } STATUS current DESCRIPTION "HVAC-6-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 372 } -- 1.3.6.1.4.1.9839.1000.373 trapV1-373 NOTIFICATION-TYPE OBJECTS { al-HiP-M06-Active } STATUS current DESCRIPTION "HVAC-6-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 373 } -- 1.3.6.1.4.1.9839.1000.374 trapV1-374 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M06-Active } STATUS current DESCRIPTION "HVAC-6-DC-Failover-Active-Alarm-status" ::= { snmpTraps 374 } -- 1.3.6.1.4.1.9839.1000.375 trapV1-375 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M06-Active } STATUS current DESCRIPTION "HVAC-6-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 375 } -- 1.3.6.1.4.1.9839.1000.376 trapV1-376 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M06-Active } STATUS current DESCRIPTION "HVAC-6-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 376 } -- 1.3.6.1.4.1.9839.1000.377 trapV1-377 NOTIFICATION-TYPE OBJECTS { al-LowP-M06-Active } STATUS current DESCRIPTION "HVAC-6-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 377 } -- 1.3.6.1.4.1.9839.1000.378 trapV1-378 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M06-Active } STATUS current DESCRIPTION "HVAC-6-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 378 } -- 1.3.6.1.4.1.9839.1000.379 trapV1-379 NOTIFICATION-TYPE OBJECTS { al-Filt-M06-Active } STATUS current DESCRIPTION "HVAC-6-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 379 } -- 1.3.6.1.4.1.9839.1000.380 trapV1-380 NOTIFICATION-TYPE OBJECTS { al-Dust-M06-Active } STATUS current DESCRIPTION "HVAC-6-AFPD-Triggered-Alarm-status" ::= { snmpTraps 380 } -- 1.3.6.1.4.1.9839.1000.381 trapV1-381 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M06-Active } STATUS current DESCRIPTION "HVAC-6-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 381 } -- 1.3.6.1.4.1.9839.1000.382 trapV1-382 NOTIFICATION-TYPE OBJECTS { al-Damper-M06-Active } STATUS current DESCRIPTION "HVAC-6-Damper-Alarm-Alarm-status" ::= { snmpTraps 382 } -- 1.3.6.1.4.1.9839.1000.383 trapV1-383 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M06-Active } STATUS current DESCRIPTION "HVAC-6-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 383 } -- 1.3.6.1.4.1.9839.1000.384 trapV1-384 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M06-Active } STATUS current DESCRIPTION "HVAC-6-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 384 } -- 1.3.6.1.4.1.9839.1000.385 trapV1-385 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M06-Active } STATUS current DESCRIPTION "HVAC-6-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 385 } -- 1.3.6.1.4.1.9839.1000.386 trapV1-386 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M06-Active } STATUS current DESCRIPTION "HVAC-6-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 386 } -- 1.3.6.1.4.1.9839.1000.387 trapV1-387 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M06-Active } STATUS current DESCRIPTION "HVAC-6-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 387 } -- 1.3.6.1.4.1.9839.1000.388 trapV1-388 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M06-Active } STATUS current DESCRIPTION "HVAC-6-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 388 } -- 1.3.6.1.4.1.9839.1000.389 trapV1-389 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M06-Active } STATUS current DESCRIPTION "HVAC-6-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 389 } -- 1.3.6.1.4.1.9839.1000.390 trapV1-390 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M06-Active } STATUS current DESCRIPTION "HVAC-6-EEV-Alarm-Alarm-status" ::= { snmpTraps 390 } -- 1.3.6.1.4.1.9839.1000.391 trapV1-391 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M06-Active } STATUS current DESCRIPTION "HVAC-6-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 391 } -- 1.3.6.1.4.1.9839.1000.392 trapV1-392 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M06-Active } STATUS current DESCRIPTION "HVAC-6-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 392 } -- 1.3.6.1.4.1.9839.1000.393 trapV1-393 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M06-Active } STATUS current DESCRIPTION "HVAC-6-Inverter-Offline-Alarm-status" ::= { snmpTraps 393 } -- 1.3.6.1.4.1.9839.1000.394 trapV1-394 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M06-Active } STATUS current DESCRIPTION "HVAC-6-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 394 } -- 1.3.6.1.4.1.9839.1000.395 trapV1-395 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M06-Active } STATUS current DESCRIPTION "HVAC-6-BLDC-Alarm-Alarm-status" ::= { snmpTraps 395 } -- 1.3.6.1.4.1.9839.1000.396 trapV1-396 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M06-Active } STATUS current DESCRIPTION "HVAC-6-Dirty-Condenser-Alarm-status" ::= { snmpTraps 396 } -- 1.3.6.1.4.1.9839.1000.397 trapV1-397 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M06-Active } STATUS current DESCRIPTION "HVAC-6-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 397 } -- 1.3.6.1.4.1.9839.1000.398 trapV1-398 NOTIFICATION-TYPE OBJECTS { al-retain-M07-Active } STATUS current DESCRIPTION "HVAC-7-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 398 } -- 1.3.6.1.4.1.9839.1000.399 trapV1-399 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M07-Active } STATUS current DESCRIPTION "HVAC-7-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 399 } -- 1.3.6.1.4.1.9839.1000.400 trapV1-400 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M07-Active } STATUS current DESCRIPTION "HVAC-7-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 400 } -- 1.3.6.1.4.1.9839.1000.401 trapV1-401 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M07-Active } STATUS current DESCRIPTION "HVAC-7-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 401 } -- 1.3.6.1.4.1.9839.1000.402 trapV1-402 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M07-Active } STATUS current DESCRIPTION "HVAC-7-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 402 } -- 1.3.6.1.4.1.9839.1000.403 trapV1-403 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M07-Active } STATUS current DESCRIPTION "HVAC-7-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 403 } -- 1.3.6.1.4.1.9839.1000.404 trapV1-404 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M07-Active } STATUS current DESCRIPTION "HVAC-7-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 404 } -- 1.3.6.1.4.1.9839.1000.405 trapV1-405 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M07-Active } STATUS current DESCRIPTION "HVAC-7-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 405 } -- 1.3.6.1.4.1.9839.1000.406 trapV1-406 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M07-Active } STATUS current DESCRIPTION "HVAC-7-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 406 } -- 1.3.6.1.4.1.9839.1000.407 trapV1-407 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M07-Active } STATUS current DESCRIPTION "HVAC-7-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 407 } -- 1.3.6.1.4.1.9839.1000.408 trapV1-408 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M07-Active } STATUS current DESCRIPTION "HVAC-7-Humidity-Alarm-Alarm-status" ::= { snmpTraps 408 } -- 1.3.6.1.4.1.9839.1000.409 trapV1-409 NOTIFICATION-TYPE OBJECTS { al-Smoke-M07-Active } STATUS current DESCRIPTION "HVAC-7-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 409 } -- 1.3.6.1.4.1.9839.1000.410 trapV1-410 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M07-Active } STATUS current DESCRIPTION "HVAC-7-Inverter-Overload-Alarm-status" ::= { snmpTraps 410 } -- 1.3.6.1.4.1.9839.1000.411 trapV1-411 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M07-Active } STATUS current DESCRIPTION "HVAC-7-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 411 } -- 1.3.6.1.4.1.9839.1000.412 trapV1-412 NOTIFICATION-TYPE OBJECTS { al-HiP-M07-Active } STATUS current DESCRIPTION "HVAC-7-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 412 } -- 1.3.6.1.4.1.9839.1000.413 trapV1-413 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M07-Active } STATUS current DESCRIPTION "HVAC-7-DC-Failover-Active-Alarm-status" ::= { snmpTraps 413 } -- 1.3.6.1.4.1.9839.1000.414 trapV1-414 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M07-Active } STATUS current DESCRIPTION "HVAC-7-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 414 } -- 1.3.6.1.4.1.9839.1000.415 trapV1-415 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M07-Active } STATUS current DESCRIPTION "HVAC-7-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 415 } -- 1.3.6.1.4.1.9839.1000.416 trapV1-416 NOTIFICATION-TYPE OBJECTS { al-LowP-M07-Active } STATUS current DESCRIPTION "HVAC-7-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 416 } -- 1.3.6.1.4.1.9839.1000.417 trapV1-417 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M07-Active } STATUS current DESCRIPTION "HVAC-7-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 417 } -- 1.3.6.1.4.1.9839.1000.418 trapV1-418 NOTIFICATION-TYPE OBJECTS { al-Filt-M07-Active } STATUS current DESCRIPTION "HVAC-7-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 418 } -- 1.3.6.1.4.1.9839.1000.419 trapV1-419 NOTIFICATION-TYPE OBJECTS { al-Dust-M07-Active } STATUS current DESCRIPTION "HVAC-7-AFPD-Triggered-Alarm-status" ::= { snmpTraps 419 } -- 1.3.6.1.4.1.9839.1000.420 trapV1-420 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M07-Active } STATUS current DESCRIPTION "HVAC-7-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 420 } -- 1.3.6.1.4.1.9839.1000.421 trapV1-421 NOTIFICATION-TYPE OBJECTS { al-Damper-M07-Active } STATUS current DESCRIPTION "HVAC-7-Damper-Alarm-Alarm-status" ::= { snmpTraps 421 } -- 1.3.6.1.4.1.9839.1000.422 trapV1-422 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M07-Active } STATUS current DESCRIPTION "HVAC-7-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 422 } -- 1.3.6.1.4.1.9839.1000.423 trapV1-423 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M07-Active } STATUS current DESCRIPTION "HVAC-7-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 423 } -- 1.3.6.1.4.1.9839.1000.424 trapV1-424 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M07-Active } STATUS current DESCRIPTION "HVAC-7-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 424 } -- 1.3.6.1.4.1.9839.1000.425 trapV1-425 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M07-Active } STATUS current DESCRIPTION "HVAC-7-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 425 } -- 1.3.6.1.4.1.9839.1000.426 trapV1-426 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M07-Active } STATUS current DESCRIPTION "HVAC-7-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 426 } -- 1.3.6.1.4.1.9839.1000.427 trapV1-427 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M07-Active } STATUS current DESCRIPTION "HVAC-7-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 427 } -- 1.3.6.1.4.1.9839.1000.428 trapV1-428 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M07-Active } STATUS current DESCRIPTION "HVAC-7-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 428 } -- 1.3.6.1.4.1.9839.1000.429 trapV1-429 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M07-Active } STATUS current DESCRIPTION "HVAC-7-EEV-Alarm-Alarm-status" ::= { snmpTraps 429 } -- 1.3.6.1.4.1.9839.1000.430 trapV1-430 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M07-Active } STATUS current DESCRIPTION "HVAC-7-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 430 } -- 1.3.6.1.4.1.9839.1000.431 trapV1-431 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M07-Active } STATUS current DESCRIPTION "HVAC-7-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 431 } -- 1.3.6.1.4.1.9839.1000.432 trapV1-432 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M07-Active } STATUS current DESCRIPTION "HVAC-7-Inverter-Offline-Alarm-status" ::= { snmpTraps 432 } -- 1.3.6.1.4.1.9839.1000.433 trapV1-433 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M07-Active } STATUS current DESCRIPTION "HVAC-7-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 433 } -- 1.3.6.1.4.1.9839.1000.434 trapV1-434 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M07-Active } STATUS current DESCRIPTION "HVAC-7-BLDC-Alarm-Alarm-status" ::= { snmpTraps 434 } -- 1.3.6.1.4.1.9839.1000.435 trapV1-435 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M07-Active } STATUS current DESCRIPTION "HVAC-7-Dirty-Condenser-Alarm-status" ::= { snmpTraps 435 } -- 1.3.6.1.4.1.9839.1000.436 trapV1-436 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M07-Active } STATUS current DESCRIPTION "HVAC-7-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 436 } -- 1.3.6.1.4.1.9839.1000.437 trapV1-437 NOTIFICATION-TYPE OBJECTS { al-retain-M08-Active } STATUS current DESCRIPTION "HVAC-8-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 437 } -- 1.3.6.1.4.1.9839.1000.438 trapV1-438 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M08-Active } STATUS current DESCRIPTION "HVAC-8-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 438 } -- 1.3.6.1.4.1.9839.1000.439 trapV1-439 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M08-Active } STATUS current DESCRIPTION "HVAC-8-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 439 } -- 1.3.6.1.4.1.9839.1000.440 trapV1-440 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M08-Active } STATUS current DESCRIPTION "HVAC-8-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 440 } -- 1.3.6.1.4.1.9839.1000.441 trapV1-441 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M08-Active } STATUS current DESCRIPTION "HVAC-8-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 441 } -- 1.3.6.1.4.1.9839.1000.442 trapV1-442 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M08-Active } STATUS current DESCRIPTION "HVAC-8-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 442 } -- 1.3.6.1.4.1.9839.1000.443 trapV1-443 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M08-Active } STATUS current DESCRIPTION "HVAC-8-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 443 } -- 1.3.6.1.4.1.9839.1000.444 trapV1-444 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M08-Active } STATUS current DESCRIPTION "HVAC-8-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 444 } -- 1.3.6.1.4.1.9839.1000.445 trapV1-445 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M08-Active } STATUS current DESCRIPTION "HVAC-8-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 445 } -- 1.3.6.1.4.1.9839.1000.446 trapV1-446 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M08-Active } STATUS current DESCRIPTION "HVAC-8-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 446 } -- 1.3.6.1.4.1.9839.1000.447 trapV1-447 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M08-Active } STATUS current DESCRIPTION "HVAC-8-Humidity-Alarm-Alarm-status" ::= { snmpTraps 447 } -- 1.3.6.1.4.1.9839.1000.448 trapV1-448 NOTIFICATION-TYPE OBJECTS { al-Smoke-M08-Active } STATUS current DESCRIPTION "HVAC-8-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 448 } -- 1.3.6.1.4.1.9839.1000.449 trapV1-449 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M08-Active } STATUS current DESCRIPTION "HVAC-8-Inverter-Overload-Alarm-status" ::= { snmpTraps 449 } -- 1.3.6.1.4.1.9839.1000.450 trapV1-450 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M08-Active } STATUS current DESCRIPTION "HVAC-8-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 450 } -- 1.3.6.1.4.1.9839.1000.451 trapV1-451 NOTIFICATION-TYPE OBJECTS { al-HiP-M08-Active } STATUS current DESCRIPTION "HVAC-8-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 451 } -- 1.3.6.1.4.1.9839.1000.452 trapV1-452 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M08-Active } STATUS current DESCRIPTION "HVAC-8-DC-Failover-Active-Alarm-status" ::= { snmpTraps 452 } -- 1.3.6.1.4.1.9839.1000.453 trapV1-453 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M08-Active } STATUS current DESCRIPTION "HVAC-8-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 453 } -- 1.3.6.1.4.1.9839.1000.454 trapV1-454 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M08-Active } STATUS current DESCRIPTION "HVAC-8-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 454 } -- 1.3.6.1.4.1.9839.1000.455 trapV1-455 NOTIFICATION-TYPE OBJECTS { al-LowP-M08-Active } STATUS current DESCRIPTION "HVAC-8-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 455 } -- 1.3.6.1.4.1.9839.1000.456 trapV1-456 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M08-Active } STATUS current DESCRIPTION "HVAC-8-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 456 } -- 1.3.6.1.4.1.9839.1000.457 trapV1-457 NOTIFICATION-TYPE OBJECTS { al-Filt-M08-Active } STATUS current DESCRIPTION "HVAC-8-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 457 } -- 1.3.6.1.4.1.9839.1000.458 trapV1-458 NOTIFICATION-TYPE OBJECTS { al-Dust-M08-Active } STATUS current DESCRIPTION "HVAC-8-AFPD-Triggered-Alarm-status" ::= { snmpTraps 458 } -- 1.3.6.1.4.1.9839.1000.459 trapV1-459 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M08-Active } STATUS current DESCRIPTION "HVAC-8-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 459 } -- 1.3.6.1.4.1.9839.1000.460 trapV1-460 NOTIFICATION-TYPE OBJECTS { al-Damper-M08-Active } STATUS current DESCRIPTION "HVAC-8-Damper-Alarm-Alarm-status" ::= { snmpTraps 460 } -- 1.3.6.1.4.1.9839.1000.461 trapV1-461 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M08-Active } STATUS current DESCRIPTION "HVAC-8-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 461 } -- 1.3.6.1.4.1.9839.1000.462 trapV1-462 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M08-Active } STATUS current DESCRIPTION "HVAC-8-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 462 } -- 1.3.6.1.4.1.9839.1000.463 trapV1-463 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M08-Active } STATUS current DESCRIPTION "HVAC-8-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 463 } -- 1.3.6.1.4.1.9839.1000.464 trapV1-464 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M08-Active } STATUS current DESCRIPTION "HVAC-8-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 464 } -- 1.3.6.1.4.1.9839.1000.465 trapV1-465 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M08-Active } STATUS current DESCRIPTION "HVAC-8-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 465 } -- 1.3.6.1.4.1.9839.1000.466 trapV1-466 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M08-Active } STATUS current DESCRIPTION "HVAC-8-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 466 } -- 1.3.6.1.4.1.9839.1000.467 trapV1-467 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M08-Active } STATUS current DESCRIPTION "HVAC-8-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 467 } -- 1.3.6.1.4.1.9839.1000.468 trapV1-468 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M08-Active } STATUS current DESCRIPTION "HVAC-8-EEV-Alarm-Alarm-status" ::= { snmpTraps 468 } -- 1.3.6.1.4.1.9839.1000.469 trapV1-469 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M08-Active } STATUS current DESCRIPTION "HVAC-8-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 469 } -- 1.3.6.1.4.1.9839.1000.470 trapV1-470 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M08-Active } STATUS current DESCRIPTION "HVAC-8-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 470 } -- 1.3.6.1.4.1.9839.1000.471 trapV1-471 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M08-Active } STATUS current DESCRIPTION "HVAC-8-Inverter-Offline-Alarm-status" ::= { snmpTraps 471 } -- 1.3.6.1.4.1.9839.1000.472 trapV1-472 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M08-Active } STATUS current DESCRIPTION "HVAC-8-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 472 } -- 1.3.6.1.4.1.9839.1000.473 trapV1-473 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M08-Active } STATUS current DESCRIPTION "HVAC-8-BLDC-Alarm-Alarm-status" ::= { snmpTraps 473 } -- 1.3.6.1.4.1.9839.1000.474 trapV1-474 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M08-Active } STATUS current DESCRIPTION "HVAC-8-Dirty-Condenser-Alarm-status" ::= { snmpTraps 474 } -- 1.3.6.1.4.1.9839.1000.475 trapV1-475 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M08-Active } STATUS current DESCRIPTION "HVAC-8-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 475 } -- 1.3.6.1.4.1.9839.1000.476 trapV1-476 NOTIFICATION-TYPE OBJECTS { al-retain-M09-Active } STATUS current DESCRIPTION "HVAC-9-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 476 } -- 1.3.6.1.4.1.9839.1000.477 trapV1-477 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M09-Active } STATUS current DESCRIPTION "HVAC-9-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 477 } -- 1.3.6.1.4.1.9839.1000.478 trapV1-478 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M09-Active } STATUS current DESCRIPTION "HVAC-9-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 478 } -- 1.3.6.1.4.1.9839.1000.479 trapV1-479 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M09-Active } STATUS current DESCRIPTION "HVAC-9-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 479 } -- 1.3.6.1.4.1.9839.1000.480 trapV1-480 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M09-Active } STATUS current DESCRIPTION "HVAC-9-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 480 } -- 1.3.6.1.4.1.9839.1000.481 trapV1-481 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M09-Active } STATUS current DESCRIPTION "HVAC-9-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 481 } -- 1.3.6.1.4.1.9839.1000.482 trapV1-482 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M09-Active } STATUS current DESCRIPTION "HVAC-9-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 482 } -- 1.3.6.1.4.1.9839.1000.483 trapV1-483 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M09-Active } STATUS current DESCRIPTION "HVAC-9-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 483 } -- 1.3.6.1.4.1.9839.1000.484 trapV1-484 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M09-Active } STATUS current DESCRIPTION "HVAC-9-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 484 } -- 1.3.6.1.4.1.9839.1000.485 trapV1-485 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M09-Active } STATUS current DESCRIPTION "HVAC-9-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 485 } -- 1.3.6.1.4.1.9839.1000.486 trapV1-486 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M09-Active } STATUS current DESCRIPTION "HVAC-9-Humidity-Alarm-Alarm-status" ::= { snmpTraps 486 } -- 1.3.6.1.4.1.9839.1000.487 trapV1-487 NOTIFICATION-TYPE OBJECTS { al-Smoke-M09-Active } STATUS current DESCRIPTION "HVAC-9-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 487 } -- 1.3.6.1.4.1.9839.1000.488 trapV1-488 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M09-Active } STATUS current DESCRIPTION "HVAC-9-Inverter-Overload-Alarm-status" ::= { snmpTraps 488 } -- 1.3.6.1.4.1.9839.1000.489 trapV1-489 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M09-Active } STATUS current DESCRIPTION "HVAC-9-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 489 } -- 1.3.6.1.4.1.9839.1000.490 trapV1-490 NOTIFICATION-TYPE OBJECTS { al-HiP-M09-Active } STATUS current DESCRIPTION "HVAC-9-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 490 } -- 1.3.6.1.4.1.9839.1000.491 trapV1-491 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M09-Active } STATUS current DESCRIPTION "HVAC-9-DC-Failover-Active-Alarm-status" ::= { snmpTraps 491 } -- 1.3.6.1.4.1.9839.1000.492 trapV1-492 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M09-Active } STATUS current DESCRIPTION "HVAC-9-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 492 } -- 1.3.6.1.4.1.9839.1000.493 trapV1-493 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M09-Active } STATUS current DESCRIPTION "HVAC-9-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 493 } -- 1.3.6.1.4.1.9839.1000.494 trapV1-494 NOTIFICATION-TYPE OBJECTS { al-LowP-M09-Active } STATUS current DESCRIPTION "HVAC-9-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 494 } -- 1.3.6.1.4.1.9839.1000.495 trapV1-495 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M09-Active } STATUS current DESCRIPTION "HVAC-9-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 495 } -- 1.3.6.1.4.1.9839.1000.496 trapV1-496 NOTIFICATION-TYPE OBJECTS { al-Filt-M09-Active } STATUS current DESCRIPTION "HVAC-9-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 496 } -- 1.3.6.1.4.1.9839.1000.497 trapV1-497 NOTIFICATION-TYPE OBJECTS { al-Dust-M09-Active } STATUS current DESCRIPTION "HVAC-9-AFPD-Triggered-Alarm-status" ::= { snmpTraps 497 } -- 1.3.6.1.4.1.9839.1000.498 trapV1-498 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M09-Active } STATUS current DESCRIPTION "HVAC-9-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 498 } -- 1.3.6.1.4.1.9839.1000.499 trapV1-499 NOTIFICATION-TYPE OBJECTS { al-Damper-M09-Active } STATUS current DESCRIPTION "HVAC-9-Damper-Alarm-Alarm-status" ::= { snmpTraps 499 } -- 1.3.6.1.4.1.9839.1000.500 trapV1-500 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M09-Active } STATUS current DESCRIPTION "HVAC-9-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 500 } -- 1.3.6.1.4.1.9839.1000.501 trapV1-501 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M09-Active } STATUS current DESCRIPTION "HVAC-9-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 501 } -- 1.3.6.1.4.1.9839.1000.502 trapV1-502 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M09-Active } STATUS current DESCRIPTION "HVAC-9-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 502 } -- 1.3.6.1.4.1.9839.1000.503 trapV1-503 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M09-Active } STATUS current DESCRIPTION "HVAC-9-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 503 } -- 1.3.6.1.4.1.9839.1000.504 trapV1-504 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M09-Active } STATUS current DESCRIPTION "HVAC-9-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 504 } -- 1.3.6.1.4.1.9839.1000.505 trapV1-505 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M09-Active } STATUS current DESCRIPTION "HVAC-9-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 505 } -- 1.3.6.1.4.1.9839.1000.506 trapV1-506 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M09-Active } STATUS current DESCRIPTION "HVAC-9-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 506 } -- 1.3.6.1.4.1.9839.1000.507 trapV1-507 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M09-Active } STATUS current DESCRIPTION "HVAC-9-EEV-Alarm-Alarm-status" ::= { snmpTraps 507 } -- 1.3.6.1.4.1.9839.1000.508 trapV1-508 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M09-Active } STATUS current DESCRIPTION "HVAC-9-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 508 } -- 1.3.6.1.4.1.9839.1000.509 trapV1-509 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M09-Active } STATUS current DESCRIPTION "HVAC-9-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 509 } -- 1.3.6.1.4.1.9839.1000.510 trapV1-510 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M09-Active } STATUS current DESCRIPTION "HVAC-9-Inverter-Offline-Alarm-status" ::= { snmpTraps 510 } -- 1.3.6.1.4.1.9839.1000.511 trapV1-511 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M09-Active } STATUS current DESCRIPTION "HVAC-9-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 511 } -- 1.3.6.1.4.1.9839.1000.512 trapV1-512 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M09-Active } STATUS current DESCRIPTION "HVAC-9-BLDC-Alarm-Alarm-status" ::= { snmpTraps 512 } -- 1.3.6.1.4.1.9839.1000.513 trapV1-513 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M09-Active } STATUS current DESCRIPTION "HVAC-9-Dirty-Condenser-Alarm-status" ::= { snmpTraps 513 } -- 1.3.6.1.4.1.9839.1000.514 trapV1-514 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M09-Active } STATUS current DESCRIPTION "HVAC-9-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 514 } -- 1.3.6.1.4.1.9839.1000.515 trapV1-515 NOTIFICATION-TYPE OBJECTS { al-retain-M10-Active } STATUS current DESCRIPTION "HVAC-10-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 515 } -- 1.3.6.1.4.1.9839.1000.516 trapV1-516 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M10-Active } STATUS current DESCRIPTION "HVAC-10-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 516 } -- 1.3.6.1.4.1.9839.1000.517 trapV1-517 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M10-Active } STATUS current DESCRIPTION "HVAC-10-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 517 } -- 1.3.6.1.4.1.9839.1000.518 trapV1-518 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M10-Active } STATUS current DESCRIPTION "HVAC-10-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 518 } -- 1.3.6.1.4.1.9839.1000.519 trapV1-519 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M10-Active } STATUS current DESCRIPTION "HVAC-10-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 519 } -- 1.3.6.1.4.1.9839.1000.520 trapV1-520 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M10-Active } STATUS current DESCRIPTION "HVAC-10-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 520 } -- 1.3.6.1.4.1.9839.1000.521 trapV1-521 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M10-Active } STATUS current DESCRIPTION "HVAC-10-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 521 } -- 1.3.6.1.4.1.9839.1000.522 trapV1-522 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M10-Active } STATUS current DESCRIPTION "HVAC-10-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 522 } -- 1.3.6.1.4.1.9839.1000.523 trapV1-523 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M10-Active } STATUS current DESCRIPTION "HVAC-10-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 523 } -- 1.3.6.1.4.1.9839.1000.524 trapV1-524 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M10-Active } STATUS current DESCRIPTION "HVAC-10-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 524 } -- 1.3.6.1.4.1.9839.1000.525 trapV1-525 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M10-Active } STATUS current DESCRIPTION "HVAC-10-Humidity-Alarm-Alarm-status" ::= { snmpTraps 525 } -- 1.3.6.1.4.1.9839.1000.526 trapV1-526 NOTIFICATION-TYPE OBJECTS { al-Smoke-M10-Active } STATUS current DESCRIPTION "HVAC-10-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 526 } -- 1.3.6.1.4.1.9839.1000.527 trapV1-527 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M10-Active } STATUS current DESCRIPTION "HVAC-10-Inverter-Overload-Alarm-status" ::= { snmpTraps 527 } -- 1.3.6.1.4.1.9839.1000.528 trapV1-528 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M10-Active } STATUS current DESCRIPTION "HVAC-10-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 528 } -- 1.3.6.1.4.1.9839.1000.529 trapV1-529 NOTIFICATION-TYPE OBJECTS { al-HiP-M10-Active } STATUS current DESCRIPTION "HVAC-10-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 529 } -- 1.3.6.1.4.1.9839.1000.530 trapV1-530 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M10-Active } STATUS current DESCRIPTION "HVAC-10-DC-Failover-Active-Alarm-status" ::= { snmpTraps 530 } -- 1.3.6.1.4.1.9839.1000.531 trapV1-531 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M10-Active } STATUS current DESCRIPTION "HVAC-10-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 531 } -- 1.3.6.1.4.1.9839.1000.532 trapV1-532 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M10-Active } STATUS current DESCRIPTION "HVAC-10-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 532 } -- 1.3.6.1.4.1.9839.1000.533 trapV1-533 NOTIFICATION-TYPE OBJECTS { al-LowP-M10-Active } STATUS current DESCRIPTION "HVAC-10-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 533 } -- 1.3.6.1.4.1.9839.1000.534 trapV1-534 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M10-Active } STATUS current DESCRIPTION "HVAC-10-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 534 } -- 1.3.6.1.4.1.9839.1000.535 trapV1-535 NOTIFICATION-TYPE OBJECTS { al-Filt-M10-Active } STATUS current DESCRIPTION "HVAC-10-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 535 } -- 1.3.6.1.4.1.9839.1000.536 trapV1-536 NOTIFICATION-TYPE OBJECTS { al-Dust-M10-Active } STATUS current DESCRIPTION "HVAC-10-AFPD-Triggered-Alarm-status" ::= { snmpTraps 536 } -- 1.3.6.1.4.1.9839.1000.537 trapV1-537 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M10-Active } STATUS current DESCRIPTION "HVAC-10-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 537 } -- 1.3.6.1.4.1.9839.1000.538 trapV1-538 NOTIFICATION-TYPE OBJECTS { al-Damper-M10-Active } STATUS current DESCRIPTION "HVAC-10-Damper-Alarm-Alarm-status" ::= { snmpTraps 538 } -- 1.3.6.1.4.1.9839.1000.539 trapV1-539 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M10-Active } STATUS current DESCRIPTION "HVAC-10-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 539 } -- 1.3.6.1.4.1.9839.1000.540 trapV1-540 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M10-Active } STATUS current DESCRIPTION "HVAC-10-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 540 } -- 1.3.6.1.4.1.9839.1000.541 trapV1-541 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M10-Active } STATUS current DESCRIPTION "HVAC-10-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 541 } -- 1.3.6.1.4.1.9839.1000.542 trapV1-542 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M10-Active } STATUS current DESCRIPTION "HVAC-10-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 542 } -- 1.3.6.1.4.1.9839.1000.543 trapV1-543 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M10-Active } STATUS current DESCRIPTION "HVAC-10-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 543 } -- 1.3.6.1.4.1.9839.1000.544 trapV1-544 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M10-Active } STATUS current DESCRIPTION "HVAC-10-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 544 } -- 1.3.6.1.4.1.9839.1000.545 trapV1-545 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M10-Active } STATUS current DESCRIPTION "HVAC-10-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 545 } -- 1.3.6.1.4.1.9839.1000.546 trapV1-546 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M10-Active } STATUS current DESCRIPTION "HVAC-10-EEV-Alarm-Alarm-status" ::= { snmpTraps 546 } -- 1.3.6.1.4.1.9839.1000.547 trapV1-547 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M10-Active } STATUS current DESCRIPTION "HVAC-10-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 547 } -- 1.3.6.1.4.1.9839.1000.548 trapV1-548 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M10-Active } STATUS current DESCRIPTION "HVAC-10-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 548 } -- 1.3.6.1.4.1.9839.1000.549 trapV1-549 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M10-Active } STATUS current DESCRIPTION "HVAC-10-Inverter-Offline-Alarm-status" ::= { snmpTraps 549 } -- 1.3.6.1.4.1.9839.1000.550 trapV1-550 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M10-Active } STATUS current DESCRIPTION "HVAC-10-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 550 } -- 1.3.6.1.4.1.9839.1000.551 trapV1-551 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M10-Active } STATUS current DESCRIPTION "HVAC-10-BLDC-Alarm-Alarm-status" ::= { snmpTraps 551 } -- 1.3.6.1.4.1.9839.1000.552 trapV1-552 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M10-Active } STATUS current DESCRIPTION "HVAC-10-Dirty-Condenser-Alarm-status" ::= { snmpTraps 552 } -- 1.3.6.1.4.1.9839.1000.553 trapV1-553 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M10-Active } STATUS current DESCRIPTION "HVAC-10-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 553 } -- 1.3.6.1.4.1.9839.1000.554 trapV1-554 NOTIFICATION-TYPE OBJECTS { al-retain-M11-Active } STATUS current DESCRIPTION "HVAC-11-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 554 } -- 1.3.6.1.4.1.9839.1000.555 trapV1-555 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M11-Active } STATUS current DESCRIPTION "HVAC-11-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 555 } -- 1.3.6.1.4.1.9839.1000.556 trapV1-556 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M11-Active } STATUS current DESCRIPTION "HVAC-11-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 556 } -- 1.3.6.1.4.1.9839.1000.557 trapV1-557 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M11-Active } STATUS current DESCRIPTION "HVAC-11-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 557 } -- 1.3.6.1.4.1.9839.1000.558 trapV1-558 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M11-Active } STATUS current DESCRIPTION "HVAC-11-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 558 } -- 1.3.6.1.4.1.9839.1000.559 trapV1-559 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M11-Active } STATUS current DESCRIPTION "HVAC-11-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 559 } -- 1.3.6.1.4.1.9839.1000.560 trapV1-560 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M11-Active } STATUS current DESCRIPTION "HVAC-11-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 560 } -- 1.3.6.1.4.1.9839.1000.561 trapV1-561 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M11-Active } STATUS current DESCRIPTION "HVAC-11-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 561 } -- 1.3.6.1.4.1.9839.1000.562 trapV1-562 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M11-Active } STATUS current DESCRIPTION "HVAC-11-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 562 } -- 1.3.6.1.4.1.9839.1000.563 trapV1-563 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M11-Active } STATUS current DESCRIPTION "HVAC-11-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 563 } -- 1.3.6.1.4.1.9839.1000.564 trapV1-564 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M11-Active } STATUS current DESCRIPTION "HVAC-11-Humidity-Alarm-Alarm-status" ::= { snmpTraps 564 } -- 1.3.6.1.4.1.9839.1000.565 trapV1-565 NOTIFICATION-TYPE OBJECTS { al-Smoke-M11-Active } STATUS current DESCRIPTION "HVAC-11-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 565 } -- 1.3.6.1.4.1.9839.1000.566 trapV1-566 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M11-Active } STATUS current DESCRIPTION "HVAC-11-Inverter-Overload-Alarm-status" ::= { snmpTraps 566 } -- 1.3.6.1.4.1.9839.1000.567 trapV1-567 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M11-Active } STATUS current DESCRIPTION "HVAC-11-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 567 } -- 1.3.6.1.4.1.9839.1000.568 trapV1-568 NOTIFICATION-TYPE OBJECTS { al-HiP-M11-Active } STATUS current DESCRIPTION "HVAC-11-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 568 } -- 1.3.6.1.4.1.9839.1000.569 trapV1-569 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M11-Active } STATUS current DESCRIPTION "HVAC-11-DC-Failover-Active-Alarm-status" ::= { snmpTraps 569 } -- 1.3.6.1.4.1.9839.1000.570 trapV1-570 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M11-Active } STATUS current DESCRIPTION "HVAC-11-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 570 } -- 1.3.6.1.4.1.9839.1000.571 trapV1-571 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M11-Active } STATUS current DESCRIPTION "HVAC-11-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 571 } -- 1.3.6.1.4.1.9839.1000.572 trapV1-572 NOTIFICATION-TYPE OBJECTS { al-LowP-M11-Active } STATUS current DESCRIPTION "HVAC-11-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 572 } -- 1.3.6.1.4.1.9839.1000.573 trapV1-573 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M11-Active } STATUS current DESCRIPTION "HVAC-11-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 573 } -- 1.3.6.1.4.1.9839.1000.574 trapV1-574 NOTIFICATION-TYPE OBJECTS { al-Filt-M11-Active } STATUS current DESCRIPTION "HVAC-11-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 574 } -- 1.3.6.1.4.1.9839.1000.575 trapV1-575 NOTIFICATION-TYPE OBJECTS { al-Dust-M11-Active } STATUS current DESCRIPTION "HVAC-11-AFPD-Triggered-Alarm-status" ::= { snmpTraps 575 } -- 1.3.6.1.4.1.9839.1000.576 trapV1-576 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M11-Active } STATUS current DESCRIPTION "HVAC-11-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 576 } -- 1.3.6.1.4.1.9839.1000.577 trapV1-577 NOTIFICATION-TYPE OBJECTS { al-Damper-M11-Active } STATUS current DESCRIPTION "HVAC-11-Damper-Alarm-Alarm-status" ::= { snmpTraps 577 } -- 1.3.6.1.4.1.9839.1000.578 trapV1-578 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M11-Active } STATUS current DESCRIPTION "HVAC-11-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 578 } -- 1.3.6.1.4.1.9839.1000.579 trapV1-579 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M11-Active } STATUS current DESCRIPTION "HVAC-11-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 579 } -- 1.3.6.1.4.1.9839.1000.580 trapV1-580 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M11-Active } STATUS current DESCRIPTION "HVAC-11-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 580 } -- 1.3.6.1.4.1.9839.1000.581 trapV1-581 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M11-Active } STATUS current DESCRIPTION "HVAC-11-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 581 } -- 1.3.6.1.4.1.9839.1000.582 trapV1-582 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M11-Active } STATUS current DESCRIPTION "HVAC-11-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 582 } -- 1.3.6.1.4.1.9839.1000.583 trapV1-583 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M11-Active } STATUS current DESCRIPTION "HVAC-11-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 583 } -- 1.3.6.1.4.1.9839.1000.584 trapV1-584 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M11-Active } STATUS current DESCRIPTION "HVAC-11-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 584 } -- 1.3.6.1.4.1.9839.1000.585 trapV1-585 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M11-Active } STATUS current DESCRIPTION "HVAC-11-EEV-Alarm-Alarm-status" ::= { snmpTraps 585 } -- 1.3.6.1.4.1.9839.1000.586 trapV1-586 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M11-Active } STATUS current DESCRIPTION "HVAC-11-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 586 } -- 1.3.6.1.4.1.9839.1000.587 trapV1-587 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M11-Active } STATUS current DESCRIPTION "HVAC-11-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 587 } -- 1.3.6.1.4.1.9839.1000.588 trapV1-588 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M11-Active } STATUS current DESCRIPTION "HVAC-11-Inverter-Offline-Alarm-status" ::= { snmpTraps 588 } -- 1.3.6.1.4.1.9839.1000.589 trapV1-589 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M11-Active } STATUS current DESCRIPTION "HVAC-11-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 589 } -- 1.3.6.1.4.1.9839.1000.590 trapV1-590 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M11-Active } STATUS current DESCRIPTION "HVAC-11-BLDC-Alarm-Alarm-status" ::= { snmpTraps 590 } -- 1.3.6.1.4.1.9839.1000.591 trapV1-591 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M11-Active } STATUS current DESCRIPTION "HVAC-11-Dirty-Condenser-Alarm-status" ::= { snmpTraps 591 } -- 1.3.6.1.4.1.9839.1000.592 trapV1-592 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M11-Active } STATUS current DESCRIPTION "HVAC-11-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 592 } -- 1.3.6.1.4.1.9839.1000.593 trapV1-593 NOTIFICATION-TYPE OBJECTS { al-retain-M12-Active } STATUS current DESCRIPTION "HVAC-12-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 593 } -- 1.3.6.1.4.1.9839.1000.594 trapV1-594 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M12-Active } STATUS current DESCRIPTION "HVAC-12-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 594 } -- 1.3.6.1.4.1.9839.1000.595 trapV1-595 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M12-Active } STATUS current DESCRIPTION "HVAC-12-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 595 } -- 1.3.6.1.4.1.9839.1000.596 trapV1-596 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M12-Active } STATUS current DESCRIPTION "HVAC-12-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 596 } -- 1.3.6.1.4.1.9839.1000.597 trapV1-597 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M12-Active } STATUS current DESCRIPTION "HVAC-12-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 597 } -- 1.3.6.1.4.1.9839.1000.598 trapV1-598 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M12-Active } STATUS current DESCRIPTION "HVAC-12-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 598 } -- 1.3.6.1.4.1.9839.1000.599 trapV1-599 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M12-Active } STATUS current DESCRIPTION "HVAC-12-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 599 } -- 1.3.6.1.4.1.9839.1000.600 trapV1-600 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M12-Active } STATUS current DESCRIPTION "HVAC-12-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 600 } -- 1.3.6.1.4.1.9839.1000.601 trapV1-601 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M12-Active } STATUS current DESCRIPTION "HVAC-12-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 601 } -- 1.3.6.1.4.1.9839.1000.602 trapV1-602 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M12-Active } STATUS current DESCRIPTION "HVAC-12-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 602 } -- 1.3.6.1.4.1.9839.1000.603 trapV1-603 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M12-Active } STATUS current DESCRIPTION "HVAC-12-Humidity-Alarm-Alarm-status" ::= { snmpTraps 603 } -- 1.3.6.1.4.1.9839.1000.604 trapV1-604 NOTIFICATION-TYPE OBJECTS { al-Smoke-M12-Active } STATUS current DESCRIPTION "HVAC-12-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 604 } -- 1.3.6.1.4.1.9839.1000.605 trapV1-605 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M12-Active } STATUS current DESCRIPTION "HVAC-12-Inverter-Overload-Alarm-status" ::= { snmpTraps 605 } -- 1.3.6.1.4.1.9839.1000.606 trapV1-606 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M12-Active } STATUS current DESCRIPTION "HVAC-12-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 606 } -- 1.3.6.1.4.1.9839.1000.607 trapV1-607 NOTIFICATION-TYPE OBJECTS { al-HiP-M12-Active } STATUS current DESCRIPTION "HVAC-12-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 607 } -- 1.3.6.1.4.1.9839.1000.608 trapV1-608 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M12-Active } STATUS current DESCRIPTION "HVAC-12-DC-Failover-Active-Alarm-status" ::= { snmpTraps 608 } -- 1.3.6.1.4.1.9839.1000.609 trapV1-609 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M12-Active } STATUS current DESCRIPTION "HVAC-12-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 609 } -- 1.3.6.1.4.1.9839.1000.610 trapV1-610 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M12-Active } STATUS current DESCRIPTION "HVAC-12-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 610 } -- 1.3.6.1.4.1.9839.1000.611 trapV1-611 NOTIFICATION-TYPE OBJECTS { al-LowP-M12-Active } STATUS current DESCRIPTION "HVAC-12-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 611 } -- 1.3.6.1.4.1.9839.1000.612 trapV1-612 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M12-Active } STATUS current DESCRIPTION "HVAC-12-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 612 } -- 1.3.6.1.4.1.9839.1000.613 trapV1-613 NOTIFICATION-TYPE OBJECTS { al-Filt-M12-Active } STATUS current DESCRIPTION "HVAC-12-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 613 } -- 1.3.6.1.4.1.9839.1000.614 trapV1-614 NOTIFICATION-TYPE OBJECTS { al-Dust-M12-Active } STATUS current DESCRIPTION "HVAC-12-AFPD-Triggered-Alarm-status" ::= { snmpTraps 614 } -- 1.3.6.1.4.1.9839.1000.615 trapV1-615 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M12-Active } STATUS current DESCRIPTION "HVAC-12-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 615 } -- 1.3.6.1.4.1.9839.1000.616 trapV1-616 NOTIFICATION-TYPE OBJECTS { al-Damper-M12-Active } STATUS current DESCRIPTION "HVAC-12-Damper-Alarm-Alarm-status" ::= { snmpTraps 616 } -- 1.3.6.1.4.1.9839.1000.617 trapV1-617 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M12-Active } STATUS current DESCRIPTION "HVAC-12-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 617 } -- 1.3.6.1.4.1.9839.1000.618 trapV1-618 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M12-Active } STATUS current DESCRIPTION "HVAC-12-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 618 } -- 1.3.6.1.4.1.9839.1000.619 trapV1-619 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M12-Active } STATUS current DESCRIPTION "HVAC-12-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 619 } -- 1.3.6.1.4.1.9839.1000.620 trapV1-620 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M12-Active } STATUS current DESCRIPTION "HVAC-12-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 620 } -- 1.3.6.1.4.1.9839.1000.621 trapV1-621 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M12-Active } STATUS current DESCRIPTION "HVAC-12-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 621 } -- 1.3.6.1.4.1.9839.1000.622 trapV1-622 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M12-Active } STATUS current DESCRIPTION "HVAC-12-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 622 } -- 1.3.6.1.4.1.9839.1000.623 trapV1-623 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M12-Active } STATUS current DESCRIPTION "HVAC-12-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 623 } -- 1.3.6.1.4.1.9839.1000.624 trapV1-624 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M12-Active } STATUS current DESCRIPTION "HVAC-12-EEV-Alarm-Alarm-status" ::= { snmpTraps 624 } -- 1.3.6.1.4.1.9839.1000.625 trapV1-625 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M12-Active } STATUS current DESCRIPTION "HVAC-12-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 625 } -- 1.3.6.1.4.1.9839.1000.626 trapV1-626 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M12-Active } STATUS current DESCRIPTION "HVAC-12-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 626 } -- 1.3.6.1.4.1.9839.1000.627 trapV1-627 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M12-Active } STATUS current DESCRIPTION "HVAC-12-Inverter-Offline-Alarm-status" ::= { snmpTraps 627 } -- 1.3.6.1.4.1.9839.1000.628 trapV1-628 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M12-Active } STATUS current DESCRIPTION "HVAC-12-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 628 } -- 1.3.6.1.4.1.9839.1000.629 trapV1-629 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M12-Active } STATUS current DESCRIPTION "HVAC-12-BLDC-Alarm-Alarm-status" ::= { snmpTraps 629 } -- 1.3.6.1.4.1.9839.1000.630 trapV1-630 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M12-Active } STATUS current DESCRIPTION "HVAC-12-Dirty-Condenser-Alarm-status" ::= { snmpTraps 630 } -- 1.3.6.1.4.1.9839.1000.631 trapV1-631 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M12-Active } STATUS current DESCRIPTION "HVAC-12-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 631 } -- 1.3.6.1.4.1.9839.1000.632 trapV1-632 NOTIFICATION-TYPE OBJECTS { al-retain-M13-Active } STATUS current DESCRIPTION "HVAC-13-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 632 } -- 1.3.6.1.4.1.9839.1000.633 trapV1-633 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M13-Active } STATUS current DESCRIPTION "HVAC-13-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 633 } -- 1.3.6.1.4.1.9839.1000.634 trapV1-634 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M13-Active } STATUS current DESCRIPTION "HVAC-13-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 634 } -- 1.3.6.1.4.1.9839.1000.635 trapV1-635 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M13-Active } STATUS current DESCRIPTION "HVAC-13-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 635 } -- 1.3.6.1.4.1.9839.1000.636 trapV1-636 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M13-Active } STATUS current DESCRIPTION "HVAC-13-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 636 } -- 1.3.6.1.4.1.9839.1000.637 trapV1-637 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M13-Active } STATUS current DESCRIPTION "HVAC-13-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 637 } -- 1.3.6.1.4.1.9839.1000.638 trapV1-638 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M13-Active } STATUS current DESCRIPTION "HVAC-13-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 638 } -- 1.3.6.1.4.1.9839.1000.639 trapV1-639 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M13-Active } STATUS current DESCRIPTION "HVAC-13-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 639 } -- 1.3.6.1.4.1.9839.1000.640 trapV1-640 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M13-Active } STATUS current DESCRIPTION "HVAC-13-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 640 } -- 1.3.6.1.4.1.9839.1000.641 trapV1-641 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M13-Active } STATUS current DESCRIPTION "HVAC-13-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 641 } -- 1.3.6.1.4.1.9839.1000.642 trapV1-642 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M13-Active } STATUS current DESCRIPTION "HVAC-13-Humidity-Alarm-Alarm-status" ::= { snmpTraps 642 } -- 1.3.6.1.4.1.9839.1000.643 trapV1-643 NOTIFICATION-TYPE OBJECTS { al-Smoke-M13-Active } STATUS current DESCRIPTION "HVAC-13-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 643 } -- 1.3.6.1.4.1.9839.1000.644 trapV1-644 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M13-Active } STATUS current DESCRIPTION "HVAC-13-Inverter-Overload-Alarm-status" ::= { snmpTraps 644 } -- 1.3.6.1.4.1.9839.1000.645 trapV1-645 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M13-Active } STATUS current DESCRIPTION "HVAC-13-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 645 } -- 1.3.6.1.4.1.9839.1000.646 trapV1-646 NOTIFICATION-TYPE OBJECTS { al-HiP-M13-Active } STATUS current DESCRIPTION "HVAC-13-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 646 } -- 1.3.6.1.4.1.9839.1000.647 trapV1-647 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M13-Active } STATUS current DESCRIPTION "HVAC-13-DC-Failover-Active-Alarm-status" ::= { snmpTraps 647 } -- 1.3.6.1.4.1.9839.1000.648 trapV1-648 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M13-Active } STATUS current DESCRIPTION "HVAC-13-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 648 } -- 1.3.6.1.4.1.9839.1000.649 trapV1-649 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M13-Active } STATUS current DESCRIPTION "HVAC-13-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 649 } -- 1.3.6.1.4.1.9839.1000.650 trapV1-650 NOTIFICATION-TYPE OBJECTS { al-LowP-M13-Active } STATUS current DESCRIPTION "HVAC-13-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 650 } -- 1.3.6.1.4.1.9839.1000.651 trapV1-651 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M13-Active } STATUS current DESCRIPTION "HVAC-13-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 651 } -- 1.3.6.1.4.1.9839.1000.652 trapV1-652 NOTIFICATION-TYPE OBJECTS { al-Filt-M13-Active } STATUS current DESCRIPTION "HVAC-13-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 652 } -- 1.3.6.1.4.1.9839.1000.653 trapV1-653 NOTIFICATION-TYPE OBJECTS { al-Dust-M13-Active } STATUS current DESCRIPTION "HVAC-13-AFPD-Triggered-Alarm-status" ::= { snmpTraps 653 } -- 1.3.6.1.4.1.9839.1000.654 trapV1-654 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M13-Active } STATUS current DESCRIPTION "HVAC-13-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 654 } -- 1.3.6.1.4.1.9839.1000.655 trapV1-655 NOTIFICATION-TYPE OBJECTS { al-Damper-M13-Active } STATUS current DESCRIPTION "HVAC-13-Damper-Alarm-Alarm-status" ::= { snmpTraps 655 } -- 1.3.6.1.4.1.9839.1000.656 trapV1-656 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M13-Active } STATUS current DESCRIPTION "HVAC-13-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 656 } -- 1.3.6.1.4.1.9839.1000.657 trapV1-657 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M13-Active } STATUS current DESCRIPTION "HVAC-13-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 657 } -- 1.3.6.1.4.1.9839.1000.658 trapV1-658 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M13-Active } STATUS current DESCRIPTION "HVAC-13-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 658 } -- 1.3.6.1.4.1.9839.1000.659 trapV1-659 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M13-Active } STATUS current DESCRIPTION "HVAC-13-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 659 } -- 1.3.6.1.4.1.9839.1000.660 trapV1-660 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M13-Active } STATUS current DESCRIPTION "HVAC-13-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 660 } -- 1.3.6.1.4.1.9839.1000.661 trapV1-661 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M13-Active } STATUS current DESCRIPTION "HVAC-13-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 661 } -- 1.3.6.1.4.1.9839.1000.662 trapV1-662 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M13-Active } STATUS current DESCRIPTION "HVAC-13-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 662 } -- 1.3.6.1.4.1.9839.1000.663 trapV1-663 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M13-Active } STATUS current DESCRIPTION "HVAC-13-EEV-Alarm-Alarm-status" ::= { snmpTraps 663 } -- 1.3.6.1.4.1.9839.1000.664 trapV1-664 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M13-Active } STATUS current DESCRIPTION "HVAC-13-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 664 } -- 1.3.6.1.4.1.9839.1000.665 trapV1-665 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M13-Active } STATUS current DESCRIPTION "HVAC-13-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 665 } -- 1.3.6.1.4.1.9839.1000.666 trapV1-666 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M13-Active } STATUS current DESCRIPTION "HVAC-13-Inverter-Offline-Alarm-status" ::= { snmpTraps 666 } -- 1.3.6.1.4.1.9839.1000.667 trapV1-667 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M13-Active } STATUS current DESCRIPTION "HVAC-13-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 667 } -- 1.3.6.1.4.1.9839.1000.668 trapV1-668 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M13-Active } STATUS current DESCRIPTION "HVAC-13-BLDC-Alarm-Alarm-status" ::= { snmpTraps 668 } -- 1.3.6.1.4.1.9839.1000.669 trapV1-669 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M13-Active } STATUS current DESCRIPTION "HVAC-13-Dirty-Condenser-Alarm-status" ::= { snmpTraps 669 } -- 1.3.6.1.4.1.9839.1000.670 trapV1-670 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M13-Active } STATUS current DESCRIPTION "HVAC-13-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 670 } -- 1.3.6.1.4.1.9839.1000.671 trapV1-671 NOTIFICATION-TYPE OBJECTS { al-retain-M14-Active } STATUS current DESCRIPTION "HVAC-14-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 671 } -- 1.3.6.1.4.1.9839.1000.672 trapV1-672 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M14-Active } STATUS current DESCRIPTION "HVAC-14-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 672 } -- 1.3.6.1.4.1.9839.1000.673 trapV1-673 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M14-Active } STATUS current DESCRIPTION "HVAC-14-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 673 } -- 1.3.6.1.4.1.9839.1000.674 trapV1-674 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M14-Active } STATUS current DESCRIPTION "HVAC-14-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 674 } -- 1.3.6.1.4.1.9839.1000.675 trapV1-675 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M14-Active } STATUS current DESCRIPTION "HVAC-14-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 675 } -- 1.3.6.1.4.1.9839.1000.676 trapV1-676 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M14-Active } STATUS current DESCRIPTION "HVAC-14-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 676 } -- 1.3.6.1.4.1.9839.1000.677 trapV1-677 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M14-Active } STATUS current DESCRIPTION "HVAC-14-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 677 } -- 1.3.6.1.4.1.9839.1000.678 trapV1-678 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M14-Active } STATUS current DESCRIPTION "HVAC-14-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 678 } -- 1.3.6.1.4.1.9839.1000.679 trapV1-679 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M14-Active } STATUS current DESCRIPTION "HVAC-14-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 679 } -- 1.3.6.1.4.1.9839.1000.680 trapV1-680 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M14-Active } STATUS current DESCRIPTION "HVAC-14-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 680 } -- 1.3.6.1.4.1.9839.1000.681 trapV1-681 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M14-Active } STATUS current DESCRIPTION "HVAC-14-Humidity-Alarm-Alarm-status" ::= { snmpTraps 681 } -- 1.3.6.1.4.1.9839.1000.682 trapV1-682 NOTIFICATION-TYPE OBJECTS { al-Smoke-M14-Active } STATUS current DESCRIPTION "HVAC-14-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 682 } -- 1.3.6.1.4.1.9839.1000.683 trapV1-683 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M14-Active } STATUS current DESCRIPTION "HVAC-14-Inverter-Overload-Alarm-status" ::= { snmpTraps 683 } -- 1.3.6.1.4.1.9839.1000.684 trapV1-684 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M14-Active } STATUS current DESCRIPTION "HVAC-14-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 684 } -- 1.3.6.1.4.1.9839.1000.685 trapV1-685 NOTIFICATION-TYPE OBJECTS { al-HiP-M14-Active } STATUS current DESCRIPTION "HVAC-14-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 685 } -- 1.3.6.1.4.1.9839.1000.686 trapV1-686 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M14-Active } STATUS current DESCRIPTION "HVAC-14-DC-Failover-Active-Alarm-status" ::= { snmpTraps 686 } -- 1.3.6.1.4.1.9839.1000.687 trapV1-687 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M14-Active } STATUS current DESCRIPTION "HVAC-14-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 687 } -- 1.3.6.1.4.1.9839.1000.688 trapV1-688 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M14-Active } STATUS current DESCRIPTION "HVAC-14-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 688 } -- 1.3.6.1.4.1.9839.1000.689 trapV1-689 NOTIFICATION-TYPE OBJECTS { al-LowP-M14-Active } STATUS current DESCRIPTION "HVAC-14-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 689 } -- 1.3.6.1.4.1.9839.1000.690 trapV1-690 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M14-Active } STATUS current DESCRIPTION "HVAC-14-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 690 } -- 1.3.6.1.4.1.9839.1000.691 trapV1-691 NOTIFICATION-TYPE OBJECTS { al-Filt-M14-Active } STATUS current DESCRIPTION "HVAC-14-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 691 } -- 1.3.6.1.4.1.9839.1000.692 trapV1-692 NOTIFICATION-TYPE OBJECTS { al-Dust-M14-Active } STATUS current DESCRIPTION "HVAC-14-AFPD-Triggered-Alarm-status" ::= { snmpTraps 692 } -- 1.3.6.1.4.1.9839.1000.693 trapV1-693 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M14-Active } STATUS current DESCRIPTION "HVAC-14-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 693 } -- 1.3.6.1.4.1.9839.1000.694 trapV1-694 NOTIFICATION-TYPE OBJECTS { al-Damper-M14-Active } STATUS current DESCRIPTION "HVAC-14-Damper-Alarm-Alarm-status" ::= { snmpTraps 694 } -- 1.3.6.1.4.1.9839.1000.695 trapV1-695 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M14-Active } STATUS current DESCRIPTION "HVAC-14-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 695 } -- 1.3.6.1.4.1.9839.1000.696 trapV1-696 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M14-Active } STATUS current DESCRIPTION "HVAC-14-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 696 } -- 1.3.6.1.4.1.9839.1000.697 trapV1-697 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M14-Active } STATUS current DESCRIPTION "HVAC-14-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 697 } -- 1.3.6.1.4.1.9839.1000.698 trapV1-698 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M14-Active } STATUS current DESCRIPTION "HVAC-14-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 698 } -- 1.3.6.1.4.1.9839.1000.699 trapV1-699 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M14-Active } STATUS current DESCRIPTION "HVAC-14-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 699 } -- 1.3.6.1.4.1.9839.1000.700 trapV1-700 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M14-Active } STATUS current DESCRIPTION "HVAC-14-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 700 } -- 1.3.6.1.4.1.9839.1000.701 trapV1-701 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M14-Active } STATUS current DESCRIPTION "HVAC-14-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 701 } -- 1.3.6.1.4.1.9839.1000.702 trapV1-702 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M14-Active } STATUS current DESCRIPTION "HVAC-14-EEV-Alarm-Alarm-status" ::= { snmpTraps 702 } -- 1.3.6.1.4.1.9839.1000.703 trapV1-703 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M14-Active } STATUS current DESCRIPTION "HVAC-14-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 703 } -- 1.3.6.1.4.1.9839.1000.704 trapV1-704 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M14-Active } STATUS current DESCRIPTION "HVAC-14-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 704 } -- 1.3.6.1.4.1.9839.1000.705 trapV1-705 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M14-Active } STATUS current DESCRIPTION "HVAC-14-Inverter-Offline-Alarm-status" ::= { snmpTraps 705 } -- 1.3.6.1.4.1.9839.1000.706 trapV1-706 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M14-Active } STATUS current DESCRIPTION "HVAC-14-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 706 } -- 1.3.6.1.4.1.9839.1000.707 trapV1-707 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M14-Active } STATUS current DESCRIPTION "HVAC-14-BLDC-Alarm-Alarm-status" ::= { snmpTraps 707 } -- 1.3.6.1.4.1.9839.1000.708 trapV1-708 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M14-Active } STATUS current DESCRIPTION "HVAC-14-Dirty-Condenser-Alarm-status" ::= { snmpTraps 708 } -- 1.3.6.1.4.1.9839.1000.709 trapV1-709 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M14-Active } STATUS current DESCRIPTION "HVAC-14-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 709 } -- 1.3.6.1.4.1.9839.1000.710 trapV1-710 NOTIFICATION-TYPE OBJECTS { al-retain-M15-Active } STATUS current DESCRIPTION "HVAC-15-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 710 } -- 1.3.6.1.4.1.9839.1000.711 trapV1-711 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M15-Active } STATUS current DESCRIPTION "HVAC-15-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 711 } -- 1.3.6.1.4.1.9839.1000.712 trapV1-712 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M15-Active } STATUS current DESCRIPTION "HVAC-15-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 712 } -- 1.3.6.1.4.1.9839.1000.713 trapV1-713 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M15-Active } STATUS current DESCRIPTION "HVAC-15-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 713 } -- 1.3.6.1.4.1.9839.1000.714 trapV1-714 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M15-Active } STATUS current DESCRIPTION "HVAC-15-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 714 } -- 1.3.6.1.4.1.9839.1000.715 trapV1-715 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M15-Active } STATUS current DESCRIPTION "HVAC-15-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 715 } -- 1.3.6.1.4.1.9839.1000.716 trapV1-716 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M15-Active } STATUS current DESCRIPTION "HVAC-15-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 716 } -- 1.3.6.1.4.1.9839.1000.717 trapV1-717 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M15-Active } STATUS current DESCRIPTION "HVAC-15-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 717 } -- 1.3.6.1.4.1.9839.1000.718 trapV1-718 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M15-Active } STATUS current DESCRIPTION "HVAC-15-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 718 } -- 1.3.6.1.4.1.9839.1000.719 trapV1-719 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M15-Active } STATUS current DESCRIPTION "HVAC-15-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 719 } -- 1.3.6.1.4.1.9839.1000.720 trapV1-720 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M15-Active } STATUS current DESCRIPTION "HVAC-15-Humidity-Alarm-Alarm-status" ::= { snmpTraps 720 } -- 1.3.6.1.4.1.9839.1000.721 trapV1-721 NOTIFICATION-TYPE OBJECTS { al-Smoke-M15-Active } STATUS current DESCRIPTION "HVAC-15-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 721 } -- 1.3.6.1.4.1.9839.1000.722 trapV1-722 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M15-Active } STATUS current DESCRIPTION "HVAC-15-Inverter-Overload-Alarm-status" ::= { snmpTraps 722 } -- 1.3.6.1.4.1.9839.1000.723 trapV1-723 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M15-Active } STATUS current DESCRIPTION "HVAC-15-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 723 } -- 1.3.6.1.4.1.9839.1000.724 trapV1-724 NOTIFICATION-TYPE OBJECTS { al-HiP-M15-Active } STATUS current DESCRIPTION "HVAC-15-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 724 } -- 1.3.6.1.4.1.9839.1000.725 trapV1-725 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M15-Active } STATUS current DESCRIPTION "HVAC-15-DC-Failover-Active-Alarm-status" ::= { snmpTraps 725 } -- 1.3.6.1.4.1.9839.1000.726 trapV1-726 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M15-Active } STATUS current DESCRIPTION "HVAC-15-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 726 } -- 1.3.6.1.4.1.9839.1000.727 trapV1-727 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M15-Active } STATUS current DESCRIPTION "HVAC-15-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 727 } -- 1.3.6.1.4.1.9839.1000.728 trapV1-728 NOTIFICATION-TYPE OBJECTS { al-LowP-M15-Active } STATUS current DESCRIPTION "HVAC-15-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 728 } -- 1.3.6.1.4.1.9839.1000.729 trapV1-729 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M15-Active } STATUS current DESCRIPTION "HVAC-15-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 729 } -- 1.3.6.1.4.1.9839.1000.730 trapV1-730 NOTIFICATION-TYPE OBJECTS { al-Filt-M15-Active } STATUS current DESCRIPTION "HVAC-15-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 730 } -- 1.3.6.1.4.1.9839.1000.731 trapV1-731 NOTIFICATION-TYPE OBJECTS { al-Dust-M15-Active } STATUS current DESCRIPTION "HVAC-15-AFPD-Triggered-Alarm-status" ::= { snmpTraps 731 } -- 1.3.6.1.4.1.9839.1000.732 trapV1-732 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M15-Active } STATUS current DESCRIPTION "HVAC-15-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 732 } -- 1.3.6.1.4.1.9839.1000.733 trapV1-733 NOTIFICATION-TYPE OBJECTS { al-Damper-M15-Active } STATUS current DESCRIPTION "HVAC-15-Damper-Alarm-Alarm-status" ::= { snmpTraps 733 } -- 1.3.6.1.4.1.9839.1000.734 trapV1-734 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M15-Active } STATUS current DESCRIPTION "HVAC-15-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 734 } -- 1.3.6.1.4.1.9839.1000.735 trapV1-735 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M15-Active } STATUS current DESCRIPTION "HVAC-15-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 735 } -- 1.3.6.1.4.1.9839.1000.736 trapV1-736 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M15-Active } STATUS current DESCRIPTION "HVAC-15-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 736 } -- 1.3.6.1.4.1.9839.1000.737 trapV1-737 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M15-Active } STATUS current DESCRIPTION "HVAC-15-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 737 } -- 1.3.6.1.4.1.9839.1000.738 trapV1-738 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M15-Active } STATUS current DESCRIPTION "HVAC-15-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 738 } -- 1.3.6.1.4.1.9839.1000.739 trapV1-739 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M15-Active } STATUS current DESCRIPTION "HVAC-15-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 739 } -- 1.3.6.1.4.1.9839.1000.740 trapV1-740 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M15-Active } STATUS current DESCRIPTION "HVAC-15-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 740 } -- 1.3.6.1.4.1.9839.1000.741 trapV1-741 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M15-Active } STATUS current DESCRIPTION "HVAC-15-EEV-Alarm-Alarm-status" ::= { snmpTraps 741 } -- 1.3.6.1.4.1.9839.1000.742 trapV1-742 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M15-Active } STATUS current DESCRIPTION "HVAC-15-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 742 } -- 1.3.6.1.4.1.9839.1000.743 trapV1-743 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M15-Active } STATUS current DESCRIPTION "HVAC-15-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 743 } -- 1.3.6.1.4.1.9839.1000.744 trapV1-744 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M15-Active } STATUS current DESCRIPTION "HVAC-15-Inverter-Offline-Alarm-status" ::= { snmpTraps 744 } -- 1.3.6.1.4.1.9839.1000.745 trapV1-745 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M15-Active } STATUS current DESCRIPTION "HVAC-15-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 745 } -- 1.3.6.1.4.1.9839.1000.746 trapV1-746 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M15-Active } STATUS current DESCRIPTION "HVAC-15-BLDC-Alarm-Alarm-status" ::= { snmpTraps 746 } -- 1.3.6.1.4.1.9839.1000.747 trapV1-747 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M15-Active } STATUS current DESCRIPTION "HVAC-15-Dirty-Condenser-Alarm-status" ::= { snmpTraps 747 } -- 1.3.6.1.4.1.9839.1000.748 trapV1-748 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M15-Active } STATUS current DESCRIPTION "HVAC-15-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 748 } -- 1.3.6.1.4.1.9839.1000.749 trapV1-749 NOTIFICATION-TYPE OBJECTS { al-retain-M16-Active } STATUS current DESCRIPTION "HVAC-16-Too-Many-Internal-Memory-Writes-Alarm-status" ::= { snmpTraps 749 } -- 1.3.6.1.4.1.9839.1000.750 trapV1-750 NOTIFICATION-TYPE OBJECTS { al-Err-retain-write-M16-Active } STATUS current DESCRIPTION "HVAC-16-Internal-Memory-Read-Write-Error-Alarm-status" ::= { snmpTraps 750 } -- 1.3.6.1.4.1.9839.1000.751 trapV1-751 NOTIFICATION-TYPE OBJECTS { al-SupplyTempPrb-M16-Active } STATUS current DESCRIPTION "HVAC-16-Supply-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 751 } -- 1.3.6.1.4.1.9839.1000.752 trapV1-752 NOTIFICATION-TYPE OBJECTS { al-RoomTempPrb-M16-Active } STATUS current DESCRIPTION "HVAC-16-Indoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 752 } -- 1.3.6.1.4.1.9839.1000.753 trapV1-753 NOTIFICATION-TYPE OBJECTS { al-AmbTempPrb-M16-Active } STATUS current DESCRIPTION "HVAC-16-Outdoor-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 753 } -- 1.3.6.1.4.1.9839.1000.754 trapV1-754 NOTIFICATION-TYPE OBJECTS { al-CompHiP-Prb-M16-Active } STATUS current DESCRIPTION "HVAC-16-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 754 } -- 1.3.6.1.4.1.9839.1000.755 trapV1-755 NOTIFICATION-TYPE OBJECTS { al-DscgTempPrb-M16-Active } STATUS current DESCRIPTION "HVAC-16-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 755 } -- 1.3.6.1.4.1.9839.1000.756 trapV1-756 NOTIFICATION-TYPE OBJECTS { al-SuctP-Prb-M16-Active } STATUS current DESCRIPTION "HVAC-16-Suction-Pressure-Sensor-Error-Alarm-status" ::= { snmpTraps 756 } -- 1.3.6.1.4.1.9839.1000.757 trapV1-757 NOTIFICATION-TYPE OBJECTS { al-SuctTemp-Prb-M16-Active } STATUS current DESCRIPTION "HVAC-16-Suction-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 757 } -- 1.3.6.1.4.1.9839.1000.758 trapV1-758 NOTIFICATION-TYPE OBJECTS { al-CondenTempPrb-M16-Active } STATUS current DESCRIPTION "HVAC-16-Condenser-Temperature-Probe-Error-Alarm-status" ::= { snmpTraps 758 } -- 1.3.6.1.4.1.9839.1000.759 trapV1-759 NOTIFICATION-TYPE OBJECTS { al-AmbHumPrb-M16-Active } STATUS current DESCRIPTION "HVAC-16-Humidity-Alarm-Alarm-status" ::= { snmpTraps 759 } -- 1.3.6.1.4.1.9839.1000.760 trapV1-760 NOTIFICATION-TYPE OBJECTS { al-Smoke-M16-Active } STATUS current DESCRIPTION "HVAC-16-Smoke-Fire-alarm-Alarm-status" ::= { snmpTraps 760 } -- 1.3.6.1.4.1.9839.1000.761 trapV1-761 NOTIFICATION-TYPE OBJECTS { al-OvldComp-M16-Active } STATUS current DESCRIPTION "HVAC-16-Inverter-Overload-Alarm-status" ::= { snmpTraps 761 } -- 1.3.6.1.4.1.9839.1000.762 trapV1-762 NOTIFICATION-TYPE OBJECTS { al-HiP-Sw-M16-Active } STATUS current DESCRIPTION "HVAC-16-High-Pressure-Switch-Error-Alarm-status" ::= { snmpTraps 762 } -- 1.3.6.1.4.1.9839.1000.763 trapV1-763 NOTIFICATION-TYPE OBJECTS { al-HiP-M16-Active } STATUS current DESCRIPTION "HVAC-16-High-Pressure-Alarm-Alarm-status" ::= { snmpTraps 763 } -- 1.3.6.1.4.1.9839.1000.764 trapV1-764 NOTIFICATION-TYPE OBJECTS { al-PwrFail-M16-Active } STATUS current DESCRIPTION "HVAC-16-DC-Failover-Active-Alarm-status" ::= { snmpTraps 764 } -- 1.3.6.1.4.1.9839.1000.765 trapV1-765 NOTIFICATION-TYPE OBJECTS { al-OvldSupplyFan-M16-Active } STATUS current DESCRIPTION "HVAC-16-Supply-Fan-Overload-Alarm-status" ::= { snmpTraps 765 } -- 1.3.6.1.4.1.9839.1000.766 trapV1-766 NOTIFICATION-TYPE OBJECTS { aL-LP-Lock-Comp-M16-Active } STATUS current DESCRIPTION "HVAC-16-Low-Press-Lockout-Alarm-status" ::= { snmpTraps 766 } -- 1.3.6.1.4.1.9839.1000.767 trapV1-767 NOTIFICATION-TYPE OBJECTS { al-LowP-M16-Active } STATUS current DESCRIPTION "HVAC-16-Low-Pressure-Alarm-Alarm-status" ::= { snmpTraps 767 } -- 1.3.6.1.4.1.9839.1000.768 trapV1-768 NOTIFICATION-TYPE OBJECTS { al-LowP-Lim-M16-Active } STATUS current DESCRIPTION "HVAC-16-Low-Pressure-Limit-Alarm-Alarm-status" ::= { snmpTraps 768 } -- 1.3.6.1.4.1.9839.1000.769 trapV1-769 NOTIFICATION-TYPE OBJECTS { al-Filt-M16-Active } STATUS current DESCRIPTION "HVAC-16-Dirty-Filter-Alarm-Alarm-status" ::= { snmpTraps 769 } -- 1.3.6.1.4.1.9839.1000.770 trapV1-770 NOTIFICATION-TYPE OBJECTS { al-Dust-M16-Active } STATUS current DESCRIPTION "HVAC-16-AFPD-Triggered-Alarm-status" ::= { snmpTraps 770 } -- 1.3.6.1.4.1.9839.1000.771 trapV1-771 NOTIFICATION-TYPE OBJECTS { al-MechanicalCoolDefect-M16-Active } STATUS current DESCRIPTION "HVAC-16-High-Supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 771 } -- 1.3.6.1.4.1.9839.1000.772 trapV1-772 NOTIFICATION-TYPE OBJECTS { al-Damper-M16-Active } STATUS current DESCRIPTION "HVAC-16-Damper-Alarm-Alarm-status" ::= { snmpTraps 772 } -- 1.3.6.1.4.1.9839.1000.773 trapV1-773 NOTIFICATION-TYPE OBJECTS { al-LowSupplyTemp-M16-Active } STATUS current DESCRIPTION "HVAC-16-Low-supply-Temperature-Alarm-Alarm-status" ::= { snmpTraps 773 } -- 1.3.6.1.4.1.9839.1000.774 trapV1-774 NOTIFICATION-TYPE OBJECTS { al-HiRoomTemp-M16-Active } STATUS current DESCRIPTION "HVAC-16-High-Temp-Alarm-Alarm-status" ::= { snmpTraps 774 } -- 1.3.6.1.4.1.9839.1000.775 trapV1-775 NOTIFICATION-TYPE OBJECTS { al-LoRoomTemp-M16-Active } STATUS current DESCRIPTION "HVAC-16-Low-Temp-Alarm-Alarm-status" ::= { snmpTraps 775 } -- 1.3.6.1.4.1.9839.1000.776 trapV1-776 NOTIFICATION-TYPE OBJECTS { al-LowSH-1-M16-Active } STATUS current DESCRIPTION "HVAC-16-Low-Superheat-Alarm-Alarm-status" ::= { snmpTraps 776 } -- 1.3.6.1.4.1.9839.1000.777 trapV1-777 NOTIFICATION-TYPE OBJECTS { al-LOP-1-M16-Active } STATUS current DESCRIPTION "HVAC-16-Low-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 777 } -- 1.3.6.1.4.1.9839.1000.778 trapV1-778 NOTIFICATION-TYPE OBJECTS { al-MOP-1-M16-Active } STATUS current DESCRIPTION "HVAC-16-High-Evaporator-Temperature-Alarm-Alarm-status" ::= { snmpTraps 778 } -- 1.3.6.1.4.1.9839.1000.779 trapV1-779 NOTIFICATION-TYPE OBJECTS { al-LowSuct-1-M16-Active } STATUS current DESCRIPTION "HVAC-16-Low-Suction-Temperature-Alarm-Alarm-status" ::= { snmpTraps 779 } -- 1.3.6.1.4.1.9839.1000.780 trapV1-780 NOTIFICATION-TYPE OBJECTS { al-EEV-1-M16-Active } STATUS current DESCRIPTION "HVAC-16-EEV-Alarm-Alarm-status" ::= { snmpTraps 780 } -- 1.3.6.1.4.1.9839.1000.781 trapV1-781 NOTIFICATION-TYPE OBJECTS { al-EmergClos-1-M16-Active } STATUS current DESCRIPTION "HVAC-16-Emergency-Ventilation-Active-Alarm-status" ::= { snmpTraps 781 } -- 1.3.6.1.4.1.9839.1000.782 trapV1-782 NOTIFICATION-TYPE OBJECTS { al-ExpansionOffline-M16-Active } STATUS current DESCRIPTION "HVAC-16-Expansion-Board-Offline-Alarm-status" ::= { snmpTraps 782 } -- 1.3.6.1.4.1.9839.1000.783 trapV1-783 NOTIFICATION-TYPE OBJECTS { al-InvOffline-PWRP-1-M16-Active } STATUS current DESCRIPTION "HVAC-16-Inverter-Offline-Alarm-status" ::= { snmpTraps 783 } -- 1.3.6.1.4.1.9839.1000.784 trapV1-784 NOTIFICATION-TYPE OBJECTS { al-FilterAirPressPrb-M16-Active } STATUS current DESCRIPTION "HVAC-16-Air-Filter-Pressure-Differential-Switch-Error-Alarm-status" ::= { snmpTraps 784 } -- 1.3.6.1.4.1.9839.1000.785 trapV1-785 NOTIFICATION-TYPE OBJECTS { al-PWRP-1-M16-Active } STATUS current DESCRIPTION "HVAC-16-BLDC-Alarm-Alarm-status" ::= { snmpTraps 785 } -- 1.3.6.1.4.1.9839.1000.786 trapV1-786 NOTIFICATION-TYPE OBJECTS { al-Condenser-dirty-M16-Active } STATUS current DESCRIPTION "HVAC-16-Dirty-Condenser-Alarm-status" ::= { snmpTraps 786 } -- 1.3.6.1.4.1.9839.1000.787 trapV1-787 NOTIFICATION-TYPE OBJECTS { al-HighDscgT-BLDC1-M16-Active } STATUS current DESCRIPTION "HVAC-16-Discharge-Temperature-Sensor-Error-Alarm-status" ::= { snmpTraps 787 } -- 1.3.6.1.4.1.9839.1000.788 trapV1-788 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-Active } STATUS current DESCRIPTION "Reversed" ::= { snmpTraps 788 } -- 1.3.6.1.4.1.9839.1000.789 trapV1-789 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M01-Active } STATUS current DESCRIPTION "HVAC-1-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 789 } -- 1.3.6.1.4.1.9839.1000.790 trapV1-790 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M02-Active } STATUS current DESCRIPTION "HVAC-2-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 790 } -- 1.3.6.1.4.1.9839.1000.791 trapV1-791 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M03-Active } STATUS current DESCRIPTION "HVAC-3-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 791 } -- 1.3.6.1.4.1.9839.1000.792 trapV1-792 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M04-Active } STATUS current DESCRIPTION "HVAC-4-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 792 } -- 1.3.6.1.4.1.9839.1000.793 trapV1-793 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M05-Active } STATUS current DESCRIPTION "HVAC-5-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 793 } -- 1.3.6.1.4.1.9839.1000.794 trapV1-794 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M06-Active } STATUS current DESCRIPTION "HVAC-6-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 794 } -- 1.3.6.1.4.1.9839.1000.795 trapV1-795 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M07-Active } STATUS current DESCRIPTION "HVAC-7-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 795 } -- 1.3.6.1.4.1.9839.1000.796 trapV1-796 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M08-Active } STATUS current DESCRIPTION "HVAC-8-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 796 } -- 1.3.6.1.4.1.9839.1000.797 trapV1-797 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M09-Active } STATUS current DESCRIPTION "HVAC-9-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 797 } -- 1.3.6.1.4.1.9839.1000.798 trapV1-798 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M10-Active } STATUS current DESCRIPTION "HVAC-10-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 798 } -- 1.3.6.1.4.1.9839.1000.799 trapV1-799 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M11-Active } STATUS current DESCRIPTION "HVAC-11-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 799 } -- 1.3.6.1.4.1.9839.1000.800 trapV1-800 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M12-Active } STATUS current DESCRIPTION "HVAC-12-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 800 } -- 1.3.6.1.4.1.9839.1000.801 trapV1-801 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M13-Active } STATUS current DESCRIPTION "HVAC-13-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 801 } -- 1.3.6.1.4.1.9839.1000.802 trapV1-802 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M14-Active } STATUS current DESCRIPTION "HVAC-14-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 802 } -- 1.3.6.1.4.1.9839.1000.803 trapV1-803 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M15-Active } STATUS current DESCRIPTION "HVAC-15-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 803 } -- 1.3.6.1.4.1.9839.1000.804 trapV1-804 NOTIFICATION-TYPE OBJECTS { al-CT-Transducer-Fail-M16-Active } STATUS current DESCRIPTION "HVAC-16-Current-Transducer-Alarm-Alarm-status" ::= { snmpTraps 804 } END -- -- sNMP.MIB --